2CDS253001R0825 ABB S203-B100 MCB 6 kA 3P Type B 100 A

2CDS253001R0825 ABB S203-B100 MCB 6 kA 3P Type B 100 A

ABB S203-B100 is a three-pole 100 A Type B miniature circuit breaker with 6 kA short-circuit breaking capacity for reliable overload and short-circuit protection in three-phase electrical circuits.

SKU: 2CDS253001R0825Alt SKU: S203B100MPN: 2CDS253001R0825
Price
List Price £202.62 ex VAT
Your Price (ex VAT) Save 45%
£111.44 45% OFF
You save £91.18 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £111.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£111.44

Why Choose the ABB S203-B100 Miniature Circuit Breaker?

The ABB S203-B100 is a robust three-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in commercial, industrial and electrical distribution applications. Rated at 100 A with a Type B tripping characteristic, it is suitable for circuits with relatively low inrush currents where dependable three-phase protection is required.

As part of the ABB S200 series, the S203-B100 combines thermal overload protection with electromagnetic short-circuit protection in a compact modular format. The Type B characteristic provides instantaneous magnetic tripping at approximately 3–5 times rated current, making the breaker particularly suitable for resistive loads and circuits without high starting currents.

The S203-B100 provides a rated short-circuit breaking capacity of 6 kA according to IEC/EN 60898-1 and is designed for DIN-rail installation in electrical distribution boards and control panels. Its three mechanically linked poles allow simultaneous isolation and protection of all three phases in a three-phase circuit.

Key Advantages

  • Reliable three-pole overload and short-circuit protection.
  • 100 A rated current for higher-current distribution circuits.
  • Type B tripping characteristic suited to loads with low inrush current.
  • 6 kA rated short-circuit breaking capacity.
  • Simultaneous switching and protection of all three phases.
  • Compact modular format for DIN-rail mounting.
  • Part of ABB's established S200 miniature circuit breaker platform.

Key Features

  • ABB S200 miniature circuit breaker series.
  • 3-pole configuration.
  • 100 A rated current.
  • Type B tripping characteristic.
  • Instantaneous magnetic trip range of approximately 3–5 × In.
  • 6 kA breaking capacity to IEC/EN 60898-1.
  • Thermal-magnetic operating mechanism for overload and short-circuit protection.
  • Suitable for 50/60 Hz AC electrical systems.
  • Modular DIN-rail mounting for distribution boards and control panels.

Reliable Three-Phase Circuit Protection

Miniature circuit breakers such as the ABB S203-B100 automatically disconnect a circuit when excessive current occurs. A thermal release responds to sustained overload conditions, while an electromagnetic release provides rapid operation during short-circuit faults, helping protect cables, equipment and downstream electrical systems.

The Type B characteristic is intended for circuits with comparatively low switching or starting currents. Combined with its three-pole construction and 100 A current rating, the S203-B100 provides a practical protection solution for three-phase distribution circuits, resistive loads and other applications where a Type B response is appropriate.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial three-phase distribution circuits.
  • Resistive electrical loads.
  • Control panels and switchboards.
  • Building electrical installations.
  • Circuits with low or moderate inrush currents.
  • Three-phase feeder and distribution protection.

Technical Specifications

Tick the specs you need, then view products that match.

Breaking Capacity 6 kA
Series S200
SKU S203B100
ABB order code 2CDS253001R0825
Product type Miniature circuit breaker (MCB)
Number of poles 3
Rated current 100 A
Tripping characteristic Type B
Magnetic trip characteristic 3–5 × In
Rated short-circuit capacity 6 kA
Rated frequency 50/60 Hz
Operating principle Thermal-magnetic
Mounting type DIN rail
Product group Protecta Plus MCB
Standard IEC/EN 60898-1

Frequently Asked Questions

What is the ABB S203-B100 used for?

The ABB S203-B100 is a three-pole miniature circuit breaker used to protect three-phase electrical circuits against overload and short-circuit currents.

What is the rated current of the ABB S203-B100?

The S203-B100 has a rated current of 100 A.

What is the breaking capacity of the S203-B100?

The ABB S203-B100 has a rated short-circuit breaking capacity of 6 kA according to IEC/EN 60898-1.

What does the Type B characteristic mean?

A Type B MCB has an instantaneous magnetic trip characteristic of approximately 3–5 times its rated current, making it suitable for circuits with relatively low inrush currents.

How is the ABB S203-B100 installed?

The S203-B100 is a modular circuit breaker designed for DIN-rail mounting in compatible electrical distribution boards, switchboards and control panels.

Trusted Circuit Protection from ABB

ABB S200 miniature circuit breakers provide dependable thermal-magnetic protection for electrical distribution systems, combining compact modular construction with reliable overload and short-circuit protection for commercial and industrial installations.