2CDS252001R0015 ABB S202-B1 Miniature Circuit Breaker 2P Type B 1 A

2CDS252001R0015 ABB S202-B1 Miniature Circuit Breaker 2P Type B 1 A

ABB S202-B1 miniature circuit breaker, a 1 A two-pole Type B MCB from the System pro M compact S200 series providing 6 kA and 10 kA breaking capacities for overload and short-circuit protection.

SKU: 2CDS252001R0015Alt SKU: S202B1MPN: 2CDS252001R0015
Price
List Price £88.61 ex VAT
Your Price (ex VAT) Save 45%
£48.74 45% OFF
You save £39.87 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £48.74
Trade pricing is personalised to your account

Manufacturer Lead Time

£48.74

Why Choose the ABB S202-B1 Miniature Circuit Breaker?

The ABB S202-B1 is a compact and reliable two-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits. As part of the established ABB System pro M compact S200 MCB series, it combines thermal overload protection with electromagnetic short-circuit protection for dependable circuit protection in commercial and industrial electrical installations.

Featuring a Type B tripping characteristic, the S202-B1 is suited to circuits with relatively low inrush currents, including control, auxiliary, instrumentation and general electrical loads. Both poles are protected, providing simultaneous two-pole circuit protection and disconnection in a compact DIN-rail-mounted device.

With a rated current of 1 A, a two-pole configuration and breaking capacities of 6 kA to IEC/EN 60898-1 and 10 kA at 400 V AC to IEC/EN 60947-2, the S202-B1 provides dependable protection for low-current circuits. ABB order code 2CDS252001R0015 identifies this specific 1 A Type B model within the S200 range.

Key Advantages

  • Reliable miniature circuit breaker for overload and short-circuit protection.
  • 1 A rated current suitable for low-current electrical and control circuits.
  • Type B tripping characteristic suited to circuits with relatively low inrush currents.
  • Two-pole design with both poles protected for simultaneous circuit disconnection.
  • Breaking capacity of 6 kA to IEC/EN 60898-1 and 10 kA at 400 V AC to IEC/EN 60947-2.
  • DIN-rail mounting enables straightforward integration into distribution boards and industrial control panels.

Key Features

  • ABB System pro M compact S200 series.
  • 1 A rated current.
  • 2-pole configuration.
  • 2 protected poles.
  • Type B tripping characteristic.
  • Thermal tripping mechanism for overload protection.
  • Electromagnetic tripping mechanism for short-circuit protection.
  • 6 kA breaking capacity at 400 V AC according to IEC/EN 60898-1.
  • 10 kA ultimate short-circuit breaking capacity at 400 V AC according to IEC/EN 60947-2.
  • Energy limiting class 3 for effective limitation of fault energy.

Reliable Two-Pole Circuit Protection

Miniature circuit breakers such as the ABB S202-B1 automatically disconnect a circuit when excessive current occurs. The S200 design combines a thermal tripping mechanism for overload protection with an electromagnetic mechanism for rapid response to short-circuit currents, helping protect conductors, equipment and connected loads.

The S202-B1 incorporates two protected poles and a Type B tripping characteristic, making it particularly suitable for low-current circuits with relatively modest normal inrush currents. Its two-pole configuration provides simultaneous disconnection, while the modular DIN-rail format makes it suitable for distribution boards, control panels and other electrical assemblies.

Typical Applications

  • Low-current control circuits.
  • Industrial control and automation panels.
  • Instrumentation and auxiliary circuits.
  • Commercial electrical installations.
  • Two-pole electrical distribution circuits.
  • Distribution boards and switchgear assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Breaking Capacity 6 kA
Series System pro M compact S200
ABB order code 2CDS252001R0015
EAN 4016779926355
Product type Miniature circuit breaker (MCB)
Number of poles 2
Number of protected poles 2
Rated current 1 A
Tripping characteristic Type B
Rated operational voltage 400 V AC
Rated voltage 400 V
Rated insulation voltage 440 V
Frequency 50–60 Hz
Breaking capacity (IEC/EN 60898-1) 6 kA at 400 V AC
Ultimate breaking capacity (IEC/EN 60947-2) 10 kA at 400 V AC
Rated impulse withstand voltage 4 kV
Energy limiting class 3
Overvoltage category III
Pollution degree 2
Protection rating IP20
Mounting type DIN rail
Terminal type Screw terminal
Maximum solid conductor cross-section 35 mm²
Maximum stranded conductor cross-section 25 mm²
Width 2 modular spaces
Built-in depth 69 mm
Operating temperature -25 to +55 °C
Electrical endurance 20,000 cycles
Standards IEC/EN 60898-1 and IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S202-B1 used for?

The ABB S202-B1 is a two-pole miniature circuit breaker used to protect low-current electrical circuits against overloads and short circuits.

What is the current rating of the S202-B1?

The S202-B1 has a rated current of 1 A.

What does the Type B characteristic mean?

The Type B tripping characteristic is suited to circuits with relatively low inrush currents, making it appropriate for many control, instrumentation, auxiliary and general electrical applications.

What is the breaking capacity of the ABB S202-B1?

The S202-B1 provides a rated short-circuit capacity of 6 kA at 400 V AC according to IEC/EN 60898-1 and an ultimate short-circuit breaking capacity of 10 kA at 400 V AC according to IEC/EN 60947-2.

How many protected poles does the ABB S202-B1 have?

The S202-B1 has two poles and two protected poles, providing overcurrent protection and simultaneous disconnection across both poles.