2CDS212001R0065 ABB SH202-B6 MCB 6kA 2P Type B 6A

2CDS212001R0065 ABB SH202-B6 MCB 6kA 2P Type B 6A

ABB SH202-B6 is a 6 A 2-pole Type B miniature circuit breaker with 6 kA breaking capacity at 230/400 V AC for overload and short-circuit protection in low-voltage electrical installations.

SKU: 2CDS212001R0065Alt SKU: SH202B6MPN: 2CDS212001R0065
Price
List Price £49.90 ex VAT
Your Price (ex VAT) Save 25%
£37.43 25% OFF
You save £12.48 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £37.43
Trade pricing is personalised to your account

Manufacturer Lead Time

£37.43

Why Choose the ABB SH202-B6 Miniature Circuit Breaker?

The ABB SH202-B6 is a compact and reliable 2-pole miniature circuit breaker (MCB) designed to provide overload and short-circuit protection for low-voltage electrical circuits. As part of the established ABB SH200 MCB series, it is a current-limiting circuit breaker combining delayed thermal tripping for overload protection with electromagnetic tripping for rapid protection against short circuits.

With a rated current of 6 A, a Type B tripping characteristic and a rated short-circuit breaking capacity of 6 kA at 230/400 V AC, the SH202-B6 is suited to circuits with relatively low inrush currents. Its B-curve characteristic makes it particularly appropriate for general residential and similar electrical loads where dependable overcurrent protection is required.

The SH202-B6 features a 2-pole configuration with two protected poles, enabling simultaneous switching and protection of two conductors. With a rated operational voltage of 400 V AC and compact dimensions of approximately 85 × 35 × 69 mm, it is designed for straightforward installation on DIN rail within consumer units, distribution boards and electrical enclosures.

Key Advantages

  • Compact 2-pole miniature circuit breaker for dependable electrical circuit protection.
  • 6 A rated current suitable for low-current residential and similar circuits.
  • Type B tripping characteristic suited to circuits with relatively low inrush currents.
  • 6 kA rated short-circuit breaking capacity at 230/400 V AC.
  • Combined thermal overload and electromagnetic short-circuit protection.
  • Two protected poles provide simultaneous overcurrent protection across both conductors.

Key Features

  • ABB SH200 miniature circuit breaker series.
  • 6 A rated current.
  • B tripping characteristic.
  • 2-pole configuration with two protected poles.
  • 6 kA breaking capacity at 230/400 V AC.
  • 400 V AC rated operational voltage.
  • 440 V maximum operational voltage.
  • 4 kV rated impulse withstand voltage.
  • 50 / 60 Hz rated frequency.
  • Current limiting class 3.
  • IP20 degree of protection.
  • Compact two-module DIN-rail-mounted design.

Reliable Overcurrent Protection for Electrical Installations

Miniature circuit breakers such as the ABB SH202-B6 protect electrical circuits, cables and connected equipment against excessive current. A delayed thermal release responds to sustained overload conditions, while the electromagnetic release provides rapid disconnection when a short circuit occurs.

The Type B characteristic is well suited to general circuits where substantial starting currents are not normally expected. Combined with its 6 A rating, two protected poles, 6 kA breaking capacity and compact DIN-rail format, the SH202-B6 provides practical circuit protection for residential and similar low-voltage electrical installations.

Typical Applications

  • Residential consumer units and distribution boards.
  • Lighting circuits and other low-current electrical loads.
  • Commercial and similar low-voltage distribution systems.
  • Electrical panels and modular enclosures.
  • Circuits with low or moderate starting currents.
  • General circuit protection requiring a 2-pole MCB.

Technical Specifications

Series SH200 MCB
ABB order code 2CDS212001R0065
EAN 4016779631044
Product type Miniature circuit breaker (MCB)
Rated current 6 A
Tripping characteristic Type B
Number of poles 2
Number of protected poles 2
Rated operational voltage 400 V AC
Maximum operational voltage 440 V AC
Rated short-circuit breaking capacity 6 kA at 230/400 V AC
Frequency 50 / 60 Hz
Rated impulse withstand voltage (Uimp) 4 kV
Current limiting class 3
Power loss 4 W total at rated operating conditions
Electrical endurance 20,000 cycles
Mechanical endurance 20,000 cycles
Terminal type Screw terminals with cable clamp
Solid conductor capacity 0.75–25 mm²
Multi-wired conductor capacity 0.75–16 mm²
Protection rating IP20
Operating temperature -25 to +55 °C
Product standard IEC/EN 60898-1
Mounting type DIN rail
Module width 2 × 17.5 mm modules
Dimensions (H × W × D) 85 × 35 × 69 mm
Weight approx. 0.25 kg

Frequently Asked Questions

What is the ABB SH202-B6 used for?

The SH202-B6 is used to protect low-voltage electrical circuits against overload and short-circuit currents, with its 2-pole configuration providing simultaneous switching and protection across both poles.

What is the rated current of the SH202-B6?

The ABB SH202-B6 has a rated current of 6 A.

What does the Type B characteristic mean?

A Type B tripping characteristic is suited to circuits with relatively low inrush currents, making this MCB appropriate for many general residential and similar electrical loads.

What is the breaking capacity of this MCB?

The SH202-B6 has a rated short-circuit breaking capacity of 6 kA at 230/400 V AC.

How many poles does the ABB SH202-B6 have?

The SH202-B6 is a 2-pole MCB with two protected poles, allowing both conductors to be switched and protected simultaneously.

Trusted ABB Circuit Protection

ABB SH200 miniature circuit breakers provide established current-limiting overcurrent protection for residential and similar low-voltage electrical installations, combining compact DIN-rail mounting with dependable thermal and electromagnetic tripping technology.