2CDS212001R0061 ABB SH202-D6 6 A Type D 2-Pole 6 kA Miniature Circuit Breaker

2CDS212001R0061 ABB SH202-D6 6 A Type D 2-Pole 6 kA Miniature Circuit Breaker

ABB SH202-D6 is a 6 A Type D 2-pole miniature circuit breaker with 6 kA breaking capacity for overload and short-circuit protection in electrical circuits with high inrush characteristics.

SKU: 2CDS212001R0061Alt SKU: SH202D6MPN: 2CDS212001R0061
Price
List Price £53.10 ex VAT
Your Price (ex VAT) Save 25%
£39.83 25% OFF
You save £13.28 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £39.83
Trade pricing is personalised to your account

Manufacturer Lead Time

£39.83

Why Choose the ABB SH202-D6 Miniature Circuit Breaker?

The ABB SH202-D6 is a 2-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits. Part of the ABB SH200 series, it combines thermal-magnetic protection with a modular DIN-rail design for dependable circuit protection in residential, commercial and electrical distribution installations.

Featuring a 6 A rated current, Type D tripping characteristic and 6 kA rated short-circuit breaking capacity, the SH202-D6 is suited to appropriately designed low-current circuits where connected equipment may produce relatively high short-duration starting or inrush currents. Its Type D characteristic provides increased tolerance of these transient currents compared with Type B and Type C characteristics.

The 2-pole configuration provides simultaneous switching and overcurrent protection across both poles. This makes the SH202-D6 a practical choice for low-current two-pole circuits requiring coordinated disconnection within a compact modular installation.

Key Advantages

  • 2-pole miniature circuit breaker for coordinated circuit protection and switching.
  • 6 A rated current for low-current electrical circuits.
  • Type D tripping characteristic suited to appropriately designed loads with high starting or inrush currents.
  • 6 kA rated short-circuit breaking capacity.
  • Provides combined overload and short-circuit protection.
  • Thermal-magnetic operating principle provides protection against sustained overloads and short-circuit faults.
  • DIN-rail construction supports straightforward integration into modular distribution and control equipment.

Key Features

  • ABB SH200 series.
  • 2-pole configuration.
  • 6 A rated current.
  • Type D tripping characteristic.
  • 6 kA rated short-circuit breaking capacity.
  • Thermal protection against sustained overload currents.
  • Magnetic protection against short-circuit fault currents.
  • Suitable for appropriately designed circuits with high short-duration inrush currents.
  • Compact modular construction for DIN-rail installation.

Reliable Protection for High-Inrush Low-Current Circuits

The ABB SH202-D6 uses thermal-magnetic protection to respond to both overload and short-circuit conditions. Its thermal mechanism responds to sustained overcurrents, while the magnetic mechanism provides rapid operation when sufficiently high short-circuit fault currents occur.

The Type D characteristic provides increased tolerance of short-duration starting and inrush currents compared with Type B and Type C characteristics. Combined with its 6 A rating and two-pole construction, the SH202-D6 is suitable for appropriately engineered circuits supplying transformers, inductive equipment and other loads that can experience comparatively high energisation currents.

Typical Applications

  • Low-current circuits with high inrush characteristics.
  • Transformer-related circuits where Type D protection is appropriate.
  • Inductive loads with high short-duration starting currents.
  • Control and auxiliary circuits with high-inrush equipment.
  • Commercial and electrical distribution installations.
  • DIN-rail control panels and distribution boards.

Technical Specifications

Series SH200
ABB order code 2CDS212001R0061
Product type Miniature circuit breaker (MCB)
Number of poles 2
Protected poles 2
Rated current 6 A
Tripping characteristic Type D
Rated operational voltage 230/400 V AC
Rated frequency 50/60 Hz
Rated short-circuit capacity (Icn) 6 kA
Rated insulation voltage (Ui) 500 V
Rated impulse withstand voltage (Uimp) 4 kV
Energy limiting class 3
Overvoltage category III
Pollution degree 2
Operating temperature -25 to +55 °C
Mounting type DIN-rail mounting
Standard IEC/EN 60898-1

Frequently Asked Questions

What is the ABB SH202-D6 used for?

The ABB SH202-D6 is used to protect 6 A two-pole electrical circuits against overloads and short circuits, particularly where appropriately designed loads can produce high short-duration starting or inrush currents.

What is the current rating of the SH202-D6?

The SH202-D6 has a rated current of 6 A.

What does the Type D characteristic mean?

The Type D tripping characteristic provides increased tolerance of short-duration starting and inrush currents, making it suitable for appropriately designed circuits containing high-inrush loads.

What is the breaking capacity of the ABB SH202-D6?

The SH202-D6 has a rated short-circuit breaking capacity of 6 kA.

How many poles does the SH202-D6 have?

The ABB SH202-D6 is a 2-pole MCB, providing coordinated switching and overcurrent protection across both poles.

Trusted Circuit Protection from ABB

ABB SH200 miniature circuit breakers provide dependable thermal-magnetic protection in a compact modular format, supporting safe and efficient circuit protection across residential, commercial and electrical distribution applications.