2CDH782010R0487 ABB S752DR-K20 MCB 25kA 2P Type K 20A Selective

2CDH782010R0487 ABB S752DR-K20 MCB 25kA 2P Type K 20A Selective

ABB S752DR-K20 is a 20 A Type K 2-pole selective main circuit breaker with a 25 kA ultimate short-circuit breaking capacity at 400 V AC for coordinated low-voltage distribution protection.

SKU: 2CDH782010R0487Alt SKU: S752DRK20MPN: 2CDH782010R0487
Price
List Price £239.89 ex VAT
Your Price (ex VAT) Save 35%
£155.93 35% OFF
You save £83.96 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £155.93
Trade pricing is personalised to your account

Manufacturer Lead Time

£155.93

Why Choose the ABB S752DR-K20 Selective Main Circuit Breaker?

The ABB S752DR-K20 is a selective 2-pole main circuit breaker (SMCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems where selectivity and continuity of supply are important. Part of the ABB S750 DR series, it combines selective protection with voltage-independent operation and DIN rail mounting.

Featuring a 20 A rated current and Type K selective characteristic, the S752DR-K20 is designed for coordinated protection with suitable downstream miniature circuit breakers. The S750 DR operating principle provides total short-circuit selectivity to downstream MCBs and high selectivity to upstream protective devices, helping isolate faults at the appropriate protection level while maintaining supply to unaffected circuits.

The S752DR-K20 provides an ultimate short-circuit breaking capacity (Icu) of 25 kA at 400 V AC and a service short-circuit breaking capacity (Ics) of 12.5 kA at 400 V AC. Its two-pole construction, screw terminals and clear red ON / green OFF contact-position indication provide a robust solution for selective commercial, industrial and building distribution systems.

Key Advantages

  • Selective 2-pole main circuit breaker for low-voltage distribution systems.
  • 20 A rated current with Type K selective characteristic.
  • 25 kA Icu at 400 V AC for demanding short-circuit protection.
  • 12.5 kA Ics at 400 V AC service short-circuit breaking capacity.
  • Provides total short-circuit selectivity to suitable downstream miniature circuit breakers.
  • Voltage-independent operating principle supports dependable protective operation.
  • Current-limiting selective operation helps minimise unnecessary interruption to unaffected circuits.
  • DIN rail mounting supports straightforward integration into electrical distribution equipment.

Key Features

  • ABB S750 DR / S752DR selective main circuit breaker series.
  • 2-pole configuration.
  • 20 A rated current.
  • Type K selective characteristic.
  • 25 kA ultimate short-circuit breaking capacity (Icu) at 400 V AC.
  • 12.5 kA service short-circuit breaking capacity (Ics) at 400 V AC.
  • Voltage-independent operating principle.
  • Current-limiting selective protection concept.
  • Red ON / green OFF contact-position indication.
  • Screw-terminal connections.
  • DIN rail mounting.
  • Designed in accordance with IEC/EN 60947-2.

Selective Main Circuit Protection and Continuity of Supply

Selective main circuit breakers are designed to coordinate with downstream protective devices so that a fault can be disconnected as close as possible to its source without unnecessarily interrupting unaffected sections of the electrical installation. The ABB S750 DR series uses a current-limiting selective operating principle and voltage-independent operation, supporting dependable group protection and continuity of supply in appropriately coordinated distribution systems.

With its 20 A rating, Type K selective characteristic, 25 kA Icu at 400 V AC and two-pole construction, the S752DR-K20 provides robust selective protection for demanding low-voltage distribution systems. Its DIN rail format and screw-terminal connections make it suitable for commercial, industrial and building installations requiring coordinated main and downstream circuit protection.

Typical Applications

  • Selective low-voltage power distribution systems.
  • Main and group circuit protection in electrical distribution boards.
  • Installations requiring selectivity with downstream MCBs.
  • Commercial electrical distribution systems.
  • Industrial electrical distribution systems.
  • Building services and meter-board applications.
  • Systems where continuity of supply is important.
  • Two-pole circuits requiring selective main protection.

Technical Specifications

Product group S800 / S800P / S750 MCB
Series S750 DR / S752DR
Order code 2CDH782010R0487
GTIN / EAN 4016779879477
Product type Selective main circuit breaker (SMCB)
Number of poles 2P
Rated current 20 A
Tripping characteristic Type K selective
Rated operational voltage 400 V AC
Rated insulation voltage (Ui) 690 V
Rated impulse withstand voltage (Uimp) 6 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 25 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 12.5 kA
Rated frequency 50 / 60 Hz
Power loss at rated operating conditions per pole 5.1 W
Protection rating IP20 / IP40
Pollution degree 3
Operating temperature -25 to +55 °C
Terminal type Screw terminals
Tightening torque 2.5–3 N·m
Contact-position indication Red ON / green OFF
Operating principle Voltage-independent
Mounting type DIN rail
Standard IEC/EN 60947-2
Dimensions (H × W × D) 130 × 54 × 96 mm
Weight approx. 0.70 kg

Frequently Asked Questions

What is the ABB S752DR-K20 used for?

The ABB S752DR-K20 is a 2-pole selective main circuit breaker used for overload and short-circuit protection in low-voltage distribution systems where selective coordination with downstream protective devices and continuity of supply are important.

What is the current rating of the ABB S752DR-K20?

The S752DR-K20 has a rated current of 20 A and uses a Type K selective characteristic.

What is the breaking capacity of the S752DR-K20?

The S752DR-K20 has an ultimate short-circuit breaking capacity (Icu) of 25 kA at 400 V AC and a service short-circuit breaking capacity (Ics) of 12.5 kA at 400 V AC.

What does selective operation mean on the ABB S752DR-K20?

Selective operation enables coordinated protective devices to isolate a downstream fault at the appropriate protection level. The ABB S750 DR series provides total short-circuit selectivity to suitable downstream MCBs, helping maintain supply to unaffected circuits.

How many poles does the ABB S752DR-K20 have?

The S752DR-K20 is a 2-pole selective main circuit breaker, providing coordinated switching and protection across two poles.

Trusted Selective Circuit Protection from ABB

ABB S750 DR selective main circuit breakers combine voltage-independent operation, current-limiting selectivity and high short-circuit interruption capability for low-voltage distribution systems where coordinated protection and continuity of supply are important.