2CDH782010R0202 ABB S752DR-E20 20 A 2-Pole E Selective 25 kA Main Circuit Breaker

2CDH782010R0202 ABB S752DR-E20 20 A 2-Pole E Selective 25 kA Main Circuit Breaker

ABB S752DR-E20 is a 20 A two-pole E-characteristic selective main circuit breaker with 25 kA ultimate breaking capacity at 400 V AC for coordinated electrical distribution protection.

SKU: 2CDH782010R0202Alt SKU: S752DRE20MPN: 2CDH782010R0202
Price
List Price £239.89 ex VAT
Your Price (ex VAT) Save 35%
£155.93 35% OFF
You save £83.96 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £155.93
Trade pricing is personalised to your account

Manufacturer Lead Time

£155.93

Why Choose the ABB S752DR-E20 Selective Main Circuit Breaker?

The ABB S752DR-E20 is a high-performance two-pole selective main circuit breaker (SMCB) designed to provide dependable overload and short-circuit protection in electrical distribution systems where selective coordination and continuity of supply are important. Part of the ABB S750 DR series, it combines a 20 A rated current, E selective tripping characteristic and high short-circuit breaking capacity.

The S752DR-E20 operates according to a voltage-independent principle and does not require a control circuit to open or close its contacts. The S750 DR range is designed to provide total selectivity with downstream miniature circuit breakers and excellent selectivity with upstream protective devices through current-limiting selectivity, helping localise electrical faults and minimise unnecessary interruption to unaffected circuits.

With a two-pole configuration, 400 V AC rated operational voltage and a rated ultimate short-circuit breaking capacity of 25 kA at 400 V AC, the S752DR-E20 is suited to demanding energy-distribution applications. Its DIN-rail format supports straightforward installation in compatible distribution equipment, while ABB order code 2CDH782010R0202 identifies this specific 20 A E-characteristic model.

Key Advantages

  • Selective main circuit breaker for coordinated electrical protection.
  • 20 A rated current with two-pole configuration.
  • E selective tripping characteristic.
  • High 25 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Voltage-independent operating principle for dependable circuit protection.
  • Designed for total selectivity with downstream MCBs.
  • Current-limiting selectivity helps maintain supply to unaffected circuits.
  • DIN-rail mounting for integration into electrical distribution equipment.

Key Features

  • ABB S750 DR selective main circuit breaker series.
  • 20 A rated current.
  • Two-pole configuration.
  • E selective tripping characteristic.
  • 400 V AC rated operational voltage.
  • 25 kA rated ultimate short-circuit breaking capacity (Icu).
  • 12.5 kA rated service short-circuit breaking capacity (Ics).
  • 50/60 Hz rated frequency.
  • Rated insulation voltage of 690 V.
  • Rated impulse withstand voltage of 6 kV.
  • Red ON / green OFF contact-position indication.
  • Screw-terminal electrical connections.
  • IP20 / IP40 protection degree.
  • DIN-rail mounting for modular distribution systems.

Reliable Selective Protection for Electrical Distribution

Selective main circuit breakers such as the ABB S752DR-E20 coordinate with other protective devices so that electrical faults can be disconnected as locally as possible. This selective operation helps reduce unnecessary interruption to unaffected circuits, supporting improved continuity and availability throughout the electrical distribution system.

The ABB S750 DR series combines voltage-independent operation with current-limiting selectivity. This makes the range particularly suitable for energy-distribution systems where dependable overload and short-circuit protection must be combined with effective coordination between upstream and downstream protective devices.

Typical Applications

  • Electrical energy distribution systems requiring selective protection.
  • Main distribution and sub-distribution boards.
  • Commercial and industrial electrical installations.
  • Building power distribution systems.
  • Installations requiring coordination with downstream miniature circuit breakers.
  • Distribution systems where continuity and availability of supply are priorities.

Technical Specifications

Series S750 DR
ABB order code 2CDH782010R0202
Product type Selective main circuit breaker (SMCB)
Number of poles 2
Rated current 20 A
Tripping characteristic E selective
Rated operational voltage 400 V AC
Rated frequency 50/60 Hz
Rated ultimate short-circuit breaking capacity (Icu) 25 kA at 400 V AC
Rated service short-circuit breaking capacity (Ics) 12.5 kA at 400 V AC
Rated insulation voltage (Ui) 690 V
Rated impulse withstand voltage (Uimp) 6 kV
Operating temperature −25 to +55 °C
Pollution degree 3
Protection degree IP20 / IP40
Contact-position indication Red ON / green OFF
Terminal type Screw terminals
Tightening torque 2.5–3 N·m
Power loss 5.4 W per pole at rated operating conditions
Dimensions (H × W × D) 130 × 54 × 96 mm
Weight approx. 0.7 kg
Mounting type DIN rail
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S752DR-E20 used for?

The ABB S752DR-E20 is a selective main circuit breaker designed to provide overload and short-circuit protection while supporting coordinated operation with other protective devices in electrical distribution systems.

What is the rated current of the ABB S752DR-E20?

The S752DR-E20 has a rated current of 20 A and uses a two-pole configuration.

What is the breaking capacity of the S752DR-E20?

The breaker has a rated ultimate short-circuit breaking capacity of 25 kA at 400 V AC and a rated service short-circuit breaking capacity of 12.5 kA at 400 V AC.

What does the E characteristic mean on the S752DR-E20?

The E selective characteristic defines the circuit breaker's tripping behaviour and supports coordinated selective protection with other protective devices in the electrical distribution system.

How is the ABB S752DR-E20 installed?

The S752DR-E20 is designed for DIN-rail mounting in compatible electrical distribution equipment and uses screw terminals for electrical connections.

Trusted Selective Circuit Protection from ABB

ABB S750 DR selective main circuit breakers provide coordinated, voltage-independent protection for electrical distribution systems where dependable fault protection, selectivity and continuity of supply are essential.