Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB S751DR-E63 is a 63 A Type E 1-pole selective main circuit breaker with a 25 kA ultimate short-circuit breaking capacity at 230 V AC for coordinated low-voltage distribution protection.
£69.12
The ABB S751DR-E63 is a selective 1-pole main circuit breaker (SMCB) designed to provide dependable overload and short-circuit protection in low-voltage electrical distribution systems where selectivity and continuity of supply are important. Part of the ABB S750 DR series, it uses a voltage-independent operating principle and is designed for DIN rail installation.
Featuring a 63 A rated current and Type E selective tripping characteristic, the S751DR-E63 is engineered for coordinated protection in selective distribution systems. ABB specifies total selectivity to suitable downstream miniature circuit breakers and high selectivity to upstream protective devices through the S750 DR series' current-limiting selective operating principle.
The S751DR-E63 provides an ultimate short-circuit breaking capacity (Icu) of 25 kA at 230 V AC and a service short-circuit breaking capacity (Ics) of 12.5 kA at 230 V AC. With screw terminals, clear red ON / green OFF contact-position indication and a compact single-pole format, it provides robust selective main circuit protection for demanding low-voltage distribution systems.
Selective main circuit breakers are designed to coordinate with other protective devices so that a downstream fault can be disconnected as close as possible to its source without unnecessarily interrupting unaffected sections of the electrical installation. The ABB S750 DR series combines a current-limiting selective protection concept with voltage-independent operation, making it particularly suitable for energy distribution systems where continuity of service is an important design requirement.
With its 63 A rating, Type E selective characteristic and 25 kA Icu at 230 V AC, the S751DR-E63 combines selective coordination with substantial short-circuit interruption capability. Its single-pole DIN rail construction makes it suitable for appropriately engineered low-voltage distribution systems where dependable coordination between main and downstream protective devices is required.
| Product group | S800 / S800P / S750 MCB |
|---|---|
| Series | S750 DR / S751DR |
| Order code | 2CDH781010R0632 |
| GTIN / EAN | 4016779879033 |
| Product type | Selective main circuit breaker (SMCB) |
| Number of poles | 1P |
| Rated current | 63 A |
| Tripping characteristic | Type E selective |
| Rated operational voltage | 230 V AC |
| Rated insulation voltage (Ui) | 690 V |
| Rated impulse withstand voltage (Uimp) | 6 kV |
| Ultimate short-circuit breaking capacity (Icu) at 230 V AC | 25 kA |
| Service short-circuit breaking capacity (Ics) at 230 V AC | 12.5 kA |
| Rated frequency | 50 / 60 Hz |
| Power loss per pole | 8.7 W |
| Protection rating | IP20 / IP40 |
| Pollution degree | 3 |
| Operating temperature | -25 to +55 °C |
| Terminal type | Screw terminals |
| Tightening torque | 2.5–3 N·m |
| Contact-position indication | Red ON / green OFF |
| Operating principle | Voltage-independent |
| Mounting type | DIN rail |
| Standard | IEC/EN 60947-2 |
| Dimensions (H × W × D) | 130 × 27 × 92 mm |
| Weight | approx. 0.35 kg |
The ABB S751DR-E63 is a 1-pole selective main circuit breaker used for overload and short-circuit protection in low-voltage distribution systems where selective coordination with other protective devices and continuity of supply are important.
The S751DR-E63 has a rated current of 63 A and uses a Type E selective tripping characteristic.
The S751DR-E63 has an ultimate short-circuit breaking capacity (Icu) of 25 kA at 230 V AC and a service short-circuit breaking capacity (Ics) of 12.5 kA at 230 V AC.
Selective operation helps coordinate the S751DR-E63 with other protective devices so that an appropriate downstream device can disconnect a downstream fault where applicable, helping minimise unnecessary interruption to unaffected parts of the electrical installation.
Yes. The S751DR-E63 uses a voltage-independent operating principle, meaning it does not rely on a control circuit to make or break the main contact.
ABB S750 DR selective main circuit breakers combine voltage-independent operation, current-limiting selectivity and high short-circuit interruption capability for low-voltage distribution systems where coordinated protection and continuity of supply are important.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.