2CDH781010R0577 ABB S751DR-K50 50 A 1-Pole K Selective 25 kA Main Circuit Breaker

2CDH781010R0577 ABB S751DR-K50 50 A 1-Pole K Selective 25 kA Main Circuit Breaker

ABB S751DR-K50 is a 50 A single-pole K-characteristic selective main circuit breaker with 25 kA ultimate breaking capacity at 230 V AC for coordinated electrical distribution protection.

SKU: 2CDH781010R0577Alt SKU: S751DRK50MPN: 2CDH781010R0577
Price
List Price £103.58 ex VAT
Your Price (ex VAT) Save 35%
£67.33 35% OFF
You save £36.25 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £67.33
Trade pricing is personalised to your account

Manufacturer Lead Time

£67.33

Why Choose the ABB S751DR-K50 Selective Main Circuit Breaker?

The ABB S751DR-K50 is a high-performance single-pole selective main circuit breaker (SMCB) designed to provide dependable overload and short-circuit protection in electrical distribution systems where continuity of supply and coordinated protection are important. Part of the ABB S750 DR series, this model combines a 50 A rated current, K selective tripping characteristic and high short-circuit breaking capacity.

The S751DR-K50 operates using a voltage-independent principle, meaning it does not rely on a separate control circuit to make or break its contacts. The S750 DR range is designed to provide total selectivity with downstream miniature circuit breakers and excellent selectivity with upstream protective devices through ABB's current-limiting selectivity principle, helping isolate faults while maintaining supply to unaffected circuits.

With a single-pole configuration, 50 A rated current and rated ultimate short-circuit breaking capacity of 25 kA at 230 V AC, the S751DR-K50 is suitable for demanding energy-distribution installations. Its DIN-rail format allows straightforward installation in compatible distribution equipment, while ABB order code 2CDH781010R0577 identifies this specific K-characteristic model.

Key Advantages

  • Selective main circuit breaker for coordinated electrical protection.
  • 50 A rated current with single-pole configuration.
  • K selective tripping characteristic.
  • High 25 kA ultimate short-circuit breaking capacity at 230 V AC.
  • Voltage-independent operating principle for dependable circuit protection.
  • Designed to provide total selectivity with downstream MCBs.
  • Current-limiting selectivity helps maintain supply to unaffected parts of the installation.
  • Compact DIN-rail mounting for electrical distribution equipment.

Key Features

  • ABB S750 DR selective main circuit breaker series.
  • 50 A rated current.
  • Single-pole configuration.
  • K selective tripping characteristic.
  • 230 V AC rated operational voltage.
  • 25 kA rated ultimate short-circuit breaking capacity (Icu).
  • 12.5 kA rated service short-circuit breaking capacity (Ics).
  • 50/60 Hz rated frequency.
  • Rated insulation voltage of 690 V.
  • Rated impulse withstand voltage of 6 kV.
  • Red ON / green OFF contact-position indication.
  • Screw-terminal electrical connections.
  • IP20 / IP40 protection degree.
  • DIN-rail mounting for modular distribution systems.

Reliable Selective Protection for Electrical Distribution

Selective main circuit breakers such as the ABB S751DR-K50 coordinate with other protective devices so that a fault can be disconnected as locally as possible. This selective operation helps prevent unnecessary interruption to unaffected circuits, supporting improved continuity and availability throughout an electrical distribution system.

The ABB S750 DR series uses a voltage-independent operating principle and current-limiting selectivity. These characteristics make the range particularly suitable for energy-distribution systems where dependable overload and short-circuit protection must be combined with effective coordination between upstream and downstream protective devices.

Typical Applications

  • Electrical energy distribution systems requiring selective protection.
  • Main distribution and sub-distribution boards.
  • Commercial and industrial electrical installations.
  • Building power distribution systems.
  • Installations requiring coordination with downstream miniature circuit breakers.
  • Distribution systems where continuity and availability of supply are priorities.

Technical Specifications

Series S750 DR
ABB order code 2CDH781010R0577
Product type Selective main circuit breaker (SMCB)
Number of poles 1
Rated current 50 A
Tripping characteristic K selective
Rated operational voltage 230 V AC
Rated frequency 50/60 Hz
Rated ultimate short-circuit breaking capacity (Icu) 25 kA at 230 V AC
Rated service short-circuit breaking capacity (Ics) 12.5 kA at 230 V AC
Rated insulation voltage (Ui) 690 V
Rated impulse withstand voltage (Uimp) 6 kV
Operating temperature −25 to +55 °C
Pollution degree 3
Protection degree IP20 / IP40
Contact-position indication Red ON / green OFF
Terminal type Screw terminals
Tightening torque 2.5–3 N·m
Power loss 7.2 W per pole at rated operating conditions
Dimensions (H × W × D) 130 × 27 × 92 mm
Weight approx. 0.35 kg
Mounting type DIN rail
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S751DR-K50 used for?

The ABB S751DR-K50 is a selective main circuit breaker designed to provide overload and short-circuit protection while coordinating with other protective devices in electrical distribution systems.

What is the rated current of the ABB S751DR-K50?

The S751DR-K50 has a rated current of 50 A and uses a single-pole configuration.

What is the breaking capacity of the S751DR-K50?

The breaker has a rated ultimate short-circuit breaking capacity of 25 kA at 230 V AC and a rated service short-circuit breaking capacity of 12.5 kA at 230 V AC.

What does the K characteristic mean on the S751DR-K50?

The K selective characteristic is designed for coordinated circuit protection, allowing the S750 DR to provide selective operation with other protective devices in the electrical distribution system.

How is the ABB S751DR-K50 installed?

The S751DR-K50 is designed for DIN-rail mounting in compatible electrical distribution equipment and uses screw terminals for electrical connections.

Trusted Selective Circuit Protection from ABB

ABB S750 DR selective main circuit breakers provide coordinated, voltage-independent protection for electrical distribution systems where high availability, dependable fault protection and selectivity between protective devices are essential.