2CDH781010R0517 ABB S751DR-K25 Selective Circuit Breaker 25 kA 1P Type K 25 A

2CDH781010R0517 ABB S751DR-K25 Selective Circuit Breaker 25 kA 1P Type K 25 A

ABB S751DR-K25 is a 25 A single-pole Type K selective circuit breaker with a 25 kA short-circuit breaking capacity for coordinated protection in demanding electrical distribution systems.

SKU: 2CDH781010R0517Alt SKU: S751DRK25MPN: 2CDH781010R0517
Price
List Price £97.52 ex VAT
Your Price (ex VAT) Save 35%
£63.39 35% OFF
You save £34.13 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £63.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£63.39

Why Choose the ABB S751DR-K25 Selective Circuit Breaker?

The ABB S751DR-K25 is a high-performance 1-pole selective circuit breaker designed to provide dependable overload and short-circuit protection in electrical distribution systems. Part of the ABB S750 selective circuit breaker family, it combines a rated current of 25 A, Type K characteristic and a high 25 kA breaking capacity.

The Type K characteristic is well suited to circuits supplying inductive loads and equipment with elevated starting currents, including motors and transformers. Combined with the selective operating design, the S751DR-K25 supports coordinated protection within distribution networks, helping the appropriate protective device isolate a fault while reducing unnecessary interruption to unaffected circuits where suitable selectivity conditions are achieved.

With its 25 A rated current, single-pole configuration and 25 kA short-circuit breaking capability, the S751DR-K25 provides robust protection for demanding distribution applications. Its modular construction supports integration into suitable electrical distribution boards and switchgear assemblies.

Key Advantages

  • High-performance selective circuit breaker for demanding distribution applications.
  • 25 A rated current for reliable circuit and equipment protection.
  • Type K characteristic suited to inductive loads and circuits with elevated starting currents.
  • High 25 kA short-circuit breaking capacity.
  • Selective protection concept supports coordinated operation with suitable downstream protective devices.
  • Single-pole construction for integration into appropriate distribution systems.

Key Features

  • ABB S750 selective circuit breaker family.
  • 1-pole configuration.
  • 25 A rated current.
  • Type K characteristic.
  • 25 kA short-circuit breaking capacity.
  • Selective protection for coordinated electrical distribution.
  • Overload and short-circuit protection.
  • Suitable for circuits supplying inductive loads.
  • Designed for demanding electrical distribution applications.
  • ABB order code 2CDH781010R0517.

Selective Protection for Reliable Electrical Distribution

Selective circuit protection is used to coordinate protective devices so that a fault can be disconnected as close as practical to its source. The ABB S751DR-K25 is designed for this type of distribution architecture, helping reduce unnecessary interruption to unaffected circuits when appropriate upstream and downstream protective devices are correctly coordinated.

Combining a 25 A rating with a high 25 kA breaking capacity, the S751DR-K25 is suitable for distribution environments where substantial prospective fault currents may occur. Its Type K characteristic makes it particularly relevant to circuits with inductive loads and increased starting currents, while its selective design supports coordinated protection in appropriately engineered commercial and industrial electrical systems.

Typical Applications

  • Selective electrical distribution systems.
  • Commercial and industrial distribution boards.
  • Main and sub-distribution assemblies.
  • Motor and machinery supply circuits.
  • Transformer and other inductive-load circuits.
  • Installations requiring coordinated upstream and downstream circuit protection.

Technical Specifications

Series S750 / S751DR
ABB order code 2CDH781010R0517
Product type Selective circuit breaker
Number of poles 1
Rated current 25 A
Characteristic Type K
Short-circuit breaking capacity 25 kA
Protection functions Overload and short-circuit protection
Selective operation Yes
Product group S800 / S800P / S750 MCB

Frequently Asked Questions

What is the ABB S751DR-K25 used for?

The ABB S751DR-K25 is a selective circuit breaker designed to provide overload and short-circuit protection in electrical distribution systems, including applications supplying inductive loads and equipment with elevated starting currents.

What is the current rating of the S751DR-K25?

The S751DR-K25 has a rated current of 25 A.

What does the Type K characteristic mean?

The Type K characteristic is suited to circuits with inductive loads and increased starting currents, making it appropriate for applications such as motors, transformers and other equipment where short-duration inrush currents are expected.

What is the breaking capacity of the ABB S751DR-K25?

The S751DR-K25 has a short-circuit breaking capacity of 25 kA, providing robust fault protection for demanding electrical distribution systems.

Why is selective circuit protection useful?

Selective protection helps coordinate upstream and downstream protective devices so that a fault can be isolated by the appropriate device while unaffected parts of the electrical installation can remain energised where the required selectivity conditions are achieved.

Trusted High-Performance Protection from ABB

ABB's S750 selective circuit protection range is designed for dependable electrical distribution applications where robust short-circuit protection, coordinated operation and continuity of supply to unaffected circuits are important system requirements.