2CDH781010R0467 ABB S751DR-K16 MCB 25kA 1P Type K 16A Selective

2CDH781010R0467 ABB S751DR-K16 MCB 25kA 1P Type K 16A Selective

ABB S751DR-K16 is a 16 A K selective 1-pole selective main circuit breaker with a 25 kA ultimate short-circuit breaking capacity at 230 V AC for coordinated low-voltage distribution protection.

SKU: 2CDH781010R0467Alt SKU: S751DRK16MPN: 2CDH781010R0467
Price
List Price £91.32 ex VAT
Your Price (ex VAT) Save 35%
£59.36 35% OFF
You save £31.96 per unit
Manufacturer Lead Time Estimated Delivery 10 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £59.36
Trade pricing is personalised to your account

Manufacturer Lead Time

£59.36

Why Choose the ABB S751DR-K16 Selective Main Circuit Breaker?

The ABB S751DR-K16 is a selective 1-pole main circuit breaker (SMCB) designed for dependable overload and short-circuit protection in electrical distribution systems where selectivity and continuity of supply are important. Part of the ABB S750 DR series, it uses a voltage-independent operating principle and is designed for DIN rail installation.

Featuring a 16 A rated current and K selective tripping characteristic, the S751DR-K16 is engineered to provide total selectivity with suitable downstream miniature circuit breakers and enhanced selectivity with upstream protective devices. Its current-limiting selective operating principle helps isolate faults at the appropriate protection level, reducing unnecessary interruption to unaffected circuits.

The S751DR-K16 provides an ultimate short-circuit breaking capacity (Icu) of 25 kA at 230 V AC and a service short-circuit breaking capacity (Ics) of 12.5 kA at 230 V AC. With screw terminals, clear red ON / green OFF contact-position indication and a compact single-pole format, it provides robust main circuit protection for selective low-voltage distribution systems.

Key Advantages

  • Selective 1-pole main circuit breaker for low-voltage distribution systems.
  • 16 A rated current with K selective tripping characteristic.
  • 25 kA Icu at 230 V AC for demanding short-circuit protection.
  • Designed to provide selectivity with suitable downstream miniature circuit breakers.
  • Voltage-independent operating principle does not require a control circuit for contact operation.
  • Current-limiting selective operation supports continuity of supply in distribution systems.
  • Red ON / green OFF contact-position indication provides clear visual status.
  • DIN rail mounting supports straightforward installation in electrical distribution equipment.

Key Features

  • ABB S750 DR / S751DR selective main circuit breaker series.
  • 1-pole configuration.
  • 16 A rated current.
  • K selective tripping characteristic.
  • 25 kA ultimate short-circuit breaking capacity (Icu) at 230 V AC.
  • 12.5 kA service short-circuit breaking capacity (Ics) at 230 V AC.
  • Voltage-independent operating principle.
  • Current-limiting selective protection concept.
  • Red ON / green OFF contact-position indication.
  • Screw-terminal connections.
  • DIN rail mounting.
  • Designed in accordance with IEC/EN 60947-2.

Selective Main Circuit Protection and Continuity of Supply

Selective main circuit breakers are designed to coordinate with other protective devices so that a downstream fault can be disconnected as close as possible to its source without unnecessarily interrupting unaffected sections of the electrical installation. The ABB S750 DR series uses a current-limiting selective operating principle and voltage-independent operation, making it particularly suitable for distribution systems with demanding continuity-of-service requirements.

With its 16 A rating, K selective characteristic and 25 kA Icu at 230 V AC, the S751DR-K16 combines selective protection with substantial short-circuit interruption capability. Its single-pole DIN rail construction makes it suitable for appropriately engineered low-voltage distribution systems where coordinated protection between main and downstream circuit breakers is required.

Typical Applications

  • Selective low-voltage power distribution systems.
  • Main circuit protection in electrical distribution boards.
  • Installations requiring coordination with downstream MCBs.
  • Commercial and industrial electrical distribution.
  • Systems where continuity of supply is a priority.
  • DIN rail distribution assemblies.
  • Electrical installations requiring high short-circuit breaking capacity.
  • Single-pole circuits requiring selective main protection.

Technical Specifications

Product group S800 / S800P / S750 MCB
Series S750 DR / S751DR
Order code 2CDH781010R0467
GTIN / EAN 4016779879064
Product type Selective main circuit breaker (SMCB)
Number of poles 1P
Rated current 16 A
Tripping characteristic K selective
Rated operational voltage 230 V AC
Rated insulation voltage (Ui) 690 V
Rated impulse withstand voltage (Uimp) 6 kV
Ultimate short-circuit breaking capacity (Icu) at 230 V AC 25 kA
Service short-circuit breaking capacity (Ics) at 230 V AC 12.5 kA
Rated frequency 50 / 60 Hz
Power loss per pole 3.9 W
Protection rating IP20 / IP40
Pollution degree 3
Operating temperature -25 to +55 °C
Terminal type Screw terminals
Tightening torque 2.5–3 N·m
Contact-position indication Red ON / green OFF
Mounting type DIN rail
Standard IEC/EN 60947-2
Dimensions (H × W × D) 130 × 27 × 92 mm
Weight approx. 0.35 kg

Frequently Asked Questions

What is the ABB S751DR-K16 used for?

The ABB S751DR-K16 is a 1-pole selective main circuit breaker used for overload and short-circuit protection in low-voltage distribution systems where selective coordination with other protective devices and continuity of supply are important.

What is the current rating of the ABB S751DR-K16?

The S751DR-K16 has a rated current of 16 A and uses a K selective tripping characteristic.

What is the breaking capacity of the S751DR-K16?

The S751DR-K16 has an ultimate short-circuit breaking capacity (Icu) of 25 kA at 230 V AC and a service short-circuit breaking capacity (Ics) of 12.5 kA at 230 V AC.

What does selective operation mean on the ABB S751DR-K16?

Selective operation helps coordinate the S751DR-K16 with other protective devices so that a fault can be disconnected by the appropriate downstream protection where applicable, helping minimise unnecessary interruption to unaffected parts of the electrical installation.

What standard does the ABB S751DR-K16 comply with?

The S751DR-K16 is designed in accordance with IEC/EN 60947-2 for low-voltage circuit breakers.

Trusted Selective Circuit Protection from ABB

ABB S750 DR selective main circuit breakers combine voltage-independent operation, current-limiting selectivity and high short-circuit interruption capability for low-voltage distribution systems where coordinated protection and continuity of supply are important.