2CDA382799R0401 ABB M302P-D40 40 A 2-Pole Type D 25 kA Magnetic Circuit Breaker

2CDA382799R0401 ABB M302P-D40 40 A 2-Pole Type D 25 kA Magnetic Circuit Breaker

ABB M302P-D40 is a 40 A two-pole Type D magnetic-only circuit breaker from the M300P range with a 25 kA breaking-capacity rating for dedicated short-circuit protection of industrial AC and DC electrical circuits.

SKU: 2CDA382799R0401Alt SKU: M302PD40MPN: 2CDA382799R0401
Price
List Price £138.70 ex VAT
Your Price (ex VAT) Save 45%
£76.29 45% OFF
You save £62.42 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £76.29
Trade pricing is personalised to your account

Manufacturer Lead Time

£76.29

Why Choose the ABB M302P-D40 Magnetic Circuit Breaker?

The ABB M302P-D40 is a compact two-pole magnetic-only circuit breaker designed to provide dedicated short-circuit protection for industrial electrical circuits. Part of ABB's M300P range within the S200M / S300P circuit-protection portfolio, it combines high fault-current performance with modular DIN-rail construction for industrial control, distribution and equipment-protection applications.

Featuring a Type D magnetic characteristic and a rated current of 40 A, the M302P-D40 is designed for circuits where comparatively high temporary inrush currents can occur during normal energisation. Its magnetic-only operating principle provides short-circuit protection without thermal overload protection, allowing overload protection to be coordinated separately where required.

The M302P-D40 combines a two-pole / two protected pole configuration with a 25 kA breaking-capacity rating. It supports AC operation within ABB's M300P platform and can also be used in two-pole series-connected DC applications up to 125 V DC. Its compact 35 mm-wide construction occupies two DIN modules for efficient integration into industrial electrical assemblies.

Key Advantages

  • Magnetic-only short-circuit protection for coordinated industrial circuit protection.
  • 40 A rated current for industrial equipment and distribution circuits.
  • Two-pole / two protected pole configuration for simultaneous multi-conductor protection.
  • Type D magnetic characteristic suited to circuits with comparatively high temporary inrush currents.
  • 25 kA breaking-capacity rating for demanding industrial installations.
  • Compact 35 mm two-module construction for straightforward DIN-rail installation.

Key Features

  • ABB M300P magnetic-only circuit breaker range.
  • 40 A rated current.
  • Two-pole / two protected pole configuration.
  • Type D magnetic characteristic.
  • 480 A rated instantaneous tripping current.
  • 25 kA breaking-capacity class.
  • 6 kV rated impulse withstand voltage.
  • 500 V rated insulation voltage.
  • Suitable for 50 / 60 Hz AC and DC applications.
  • IP20 degree of protection.

Dedicated Magnetic Short-Circuit Protection for Industrial Circuits

Unlike a conventional thermal-magnetic miniature circuit breaker, the ABB M302P-D40 provides magnetic-only short-circuit protection. This allows short-circuit and sustained overload protection to be coordinated independently within an industrial electrical system. Where complete protection against overload is required, an appropriate separate overload protection device should be incorporated into the protection scheme.

The Type D magnetic characteristic accommodates comparatively high short-duration inrush currents during normal equipment energisation. Combined with its 480 A instantaneous tripping current, two-pole configuration, 25 kA breaking-capacity class and AC/DC capability, the M302P-D40 provides a compact solution for industrial circuits requiring dedicated magnetic fault protection.

Typical Applications

  • Industrial electrical control panels.
  • Dedicated short-circuit protection circuits.
  • Industrial circuits with separately coordinated overload protection.
  • Transformers and inductive electrical loads.
  • Equipment with comparatively high temporary inrush currents.
  • AC and low-voltage DC industrial electrical systems.

Technical Specifications

Series M300P
Product family S200M / S300P MCB
ABB order code 2CDA382799R0401
Product type Magnetic-only circuit breaker
Protection function Short-circuit protection
Number of poles 2
Number of protected poles 2
Magnetic characteristic Type D
Rated current 40 A
Rated instantaneous tripping current 480 A
Breaking-capacity rating 25 kA
DC capability Up to 125 V DC with two poles connected in series
DC ultimate short-circuit breaking capacity (Icu) 25 kA
Rated insulation voltage (Ui) 500 V
Rated impulse withstand voltage (Uimp) 6 kV
Rated frequency 50 / 60 Hz and DC
Reference standard IEC/EN 60947-2
Pollution degree 3
Degree of protection IP20
Terminal type Screw terminal
Tightening torque 2.8 N·m
Operating temperature -40 to +70 °C
Mounting type DIN rail
Number of modules 2
Dimensions (H × W × D) approx. 88 × 35 × 69 mm
Weight approx. 0.248 kg

Frequently Asked Questions

What is the ABB M302P-D40 used for?

The ABB M302P-D40 is a two-pole magnetic-only circuit breaker designed to provide short-circuit protection for industrial electrical circuits, particularly where overload protection is coordinated separately.

What is the rated current of the ABB M302P-D40?

The M302P-D40 has a rated current of 40 A and a rated instantaneous magnetic tripping current of 480 A.

Does the ABB M302P-D40 provide thermal overload protection?

No. The M302P-D40 provides magnetic short-circuit protection rather than thermal overload protection. Where sustained overload protection is required, an appropriate separate protective device must be used.

What is the breaking capacity of the ABB M302P-D40?

The ABB M302P-D40 belongs to the M300P magnetic-only circuit breaker range with a 25 kA breaking-capacity rating, providing high-performance short-circuit protection for industrial applications.

Can the ABB M302P-D40 be used on DC circuits?

Yes. ABB's M300P range supports DC applications, and a two-pole device connected in series can be used up to 125 V DC with an ultimate short-circuit breaking capacity (Icu) of 25 kA.

Trusted ABB Industrial Circuit Protection

ABB M300P magnetic-only circuit breakers provide dedicated short-circuit protection for industrial electrical installations, combining high breaking performance, compact DIN-rail construction and Type D magnetic characteristics suited to coordinated protection schemes.