2CCS894001R0131 ABB S804N-D13 MCB 36 kA 4P Type D 13 A

2CCS894001R0131 ABB S804N-D13 MCB 36 kA 4P Type D 13 A

ABB S804N-D13 is a 13 A four-pole Type D high-performance miniature circuit breaker with a 36 kA short-circuit breaking capacity for demanding commercial and industrial circuit protection.

SKU: 2CCS894001R0131Alt SKU: S804ND13MPN: 2CCS894001R0131
Price
List Price £323.60 ex VAT
Your Price (ex VAT) Save 35%
£210.34 35% OFF
You save £113.26 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £210.34
Trade pricing is personalised to your account

Manufacturer Lead Time

£210.34

Why Choose the ABB S804N-D13 Miniature Circuit Breaker?

The ABB S804N-D13 is a high-performance 4-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits in demanding commercial and industrial installations. Part of the ABB S800N high-performance circuit breaker series, it combines a rated current of 13 A with a high 36 kA short-circuit breaking capacity.

Featuring a Type D tripping characteristic, the S804N-D13 is particularly suited to circuits supplying equipment with comparatively high starting or inrush currents. Thermal overload protection responds to sustained overcurrent conditions, while electromagnetic short-circuit protection provides rapid interruption during severe faults.

The S804N-D13 provides four protected poles, making it suitable for four-pole and three-phase-plus-neutral circuit arrangements requiring coordinated protection and switching. Its high-performance current-limiting construction, modular DIN-rail format and compatibility with the ABB S800 platform make it well suited to industrial distribution boards, machinery panels and automation systems.

Key Advantages

  • High 36 kA short-circuit breaking capacity for demanding electrical installations.
  • 13 A rated current for lower-current four-pole distribution and equipment circuits.
  • Type D tripping characteristic suited to equipment with comparatively high starting and inrush currents.
  • 4-pole configuration for coordinated protection and switching across four poles.
  • Thermal overload and electromagnetic short-circuit protection.
  • Current-limiting high-performance design helps reduce fault energy passed into the protected installation.

Key Features

  • ABB S800N high-performance MCB series.
  • 4-pole (4P) circuit breaker configuration.
  • 13 A rated current.
  • D-curve tripping characteristic.
  • 36 kA high breaking capacity.
  • Thermal protection against sustained overload currents.
  • Electromagnetic protection for rapid short-circuit interruption.
  • Current-limiting circuit breaker construction.
  • DIN-rail mounting for modular electrical assemblies.
  • Compatible with accessories from the ABB S800 platform.

Reliable Four-Pole Protection for High-Inrush Circuits

High-performance miniature circuit breakers such as the ABB S804N-D13 automatically disconnect electrical circuits when excessive current results from an overload or short circuit. Thermal tripping responds to sustained overload conditions, while electromagnetic tripping provides rapid operation during severe short-circuit faults, helping protect conductors and connected equipment.

The Type D characteristic provides greater tolerance of normal temporary starting currents than characteristics intended for lower-inrush loads. Combined with four protected poles and the high fault-interruption capability of the S800N platform, the S804N-D13 provides robust protection for suitable transformers, motors and other inductive equipment in demanding electrical installations.

Typical Applications

  • Three-phase-plus-neutral industrial distribution circuits.
  • Four-pole commercial and industrial distribution panels.
  • Machinery and automation control cabinets.
  • Motor and inductive load circuits.
  • Transformer-fed circuits with high temporary inrush currents.
  • High fault-level installations requiring high-performance circuit protection.

Technical Specifications

Series S800N
ABB order code 2CCS894001R0131
Product type High-performance miniature circuit breaker (MCB)
Number of poles 4P
Number of protected poles 4
Rated current 13 A
Tripping characteristic Type D
Short-circuit breaking capacity 36 kA
Rated frequency 50/60 Hz
Protection function Overload and short-circuit protection
Mounting type DIN rail
Standards IEC/EN 60947-2, IEC/EN 60898-1
Product group S800 / S800P / S750 MCB

Frequently Asked Questions

What is the ABB S804N-D13 used for?

The ABB S804N-D13 protects four-pole electrical circuits against overloads and short circuits and is particularly suited to demanding applications where comparatively high starting or inrush currents can occur.

What is the rated current of the S804N-D13?

The S804N-D13 has a rated current of 13 A.

What is the breaking capacity of the ABB S804N-D13?

The S804N-D13 has a high short-circuit breaking capacity of 36 kA, making it suitable for installations where substantial prospective fault currents may occur.

What does the Type D characteristic mean?

The Type D tripping characteristic is suited to circuits supplying equipment that can experience comparatively high temporary starting or inrush currents, including appropriate motors, transformers and other inductive loads.

How many poles does the ABB S804N-D13 have?

The S804N-D13 is a 4-pole circuit breaker with four protected poles, making it suitable for applications requiring coordinated protection and switching across four poles.

Trusted High-Performance Protection from ABB

ABB S800 high-performance miniature circuit breakers combine dependable overload and short-circuit protection with high breaking capacities, current-limiting performance and compact modular construction for demanding electrical installations.