Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB S802N-D32 is a 32 A two-pole Type D high-performance miniature circuit breaker with a 36 kA breaking capacity for reliable overload and short-circuit protection.
£109.97
The ABB S802N-D32 is a high-performance 2-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in demanding electrical distribution and industrial control systems. As part of the ABB S800N high-performance circuit breaker series, it combines high fault-current interruption capability with a compact modular design for commercial and industrial applications.
This current-limiting circuit breaker features a Type D tripping characteristic and a rated current of 32 A. Its thermal tripping mechanism provides protection against sustained overloads, while the electromagnetic mechanism responds rapidly to short-circuit faults. The Type D characteristic is particularly suitable for circuits supplying equipment with relatively high starting or inrush currents.
With a breaking capacity of 36 kA, the S802N-D32 provides robust protection in installations where substantial prospective fault currents may occur. Its two-pole configuration enables simultaneous switching and protection across two conductors, while the S800N series' current-limiting design supports rapid and dependable fault interruption.
The ABB S800N range is engineered for installations requiring compact circuit protection combined with high short-circuit interruption capability. Its thermal trip responds to sustained overload conditions, while the electromagnetic trip provides rapid interruption when severe short-circuit currents occur.
The S802N-D32 combines a 32 A current rating with a Type D trip curve and two-pole construction, making it particularly useful for circuits supplying motors, transformers and other equipment with elevated starting currents. Current-limiting operation helps reduce the energy passed through during a fault, supporting the protection of conductors and downstream electrical equipment.
| Series | S800N |
|---|---|
| ABB order code | 2CCS892001R0321 |
| Product type | High-performance miniature circuit breaker (MCB) |
| Number of poles | 2 |
| Rated current | 32 A |
| Tripping characteristic | Type D |
| Breaking capacity | 36 kA |
| Protection function | Overload and short-circuit protection |
| Trip technology | Thermal and electromagnetic |
| Mounting | Modular rail mounting |
The S802N-D32 is used to protect electrical circuits against overloads and short circuits, particularly in demanding industrial applications and circuits containing loads with elevated starting currents.
The ABB S802N-D32 has a rated current of 32 A.
The S802N-D32 uses a Type D tripping characteristic, making it suitable for equipment that can produce relatively high starting or inrush currents.
The S802N-D32 has a breaking capacity of 36 kA, providing high fault-current interruption capability for demanding installations.
The S802N-D32 is a 2-pole circuit breaker, providing simultaneous switching and protection across two conductors.
ABB S800N high-performance miniature circuit breakers provide dependable overload and short-circuit protection for demanding electrical distribution and industrial applications, combining high interruption capability, current limitation and robust modular construction.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.