2CCS892001R0255 ABB S802N-B25 25 A 2-Pole Type B High Performance MCB 36 kA

2CCS892001R0255 ABB S802N-B25 25 A 2-Pole Type B High Performance MCB 36 kA

ABB S802N-B25 is a 25 A two-pole Type B high-performance miniature circuit breaker with a 36 kA breaking capacity for reliable overload and short-circuit protection.

SKU: 2CCS892001R0255Alt SKU: S802NB25MPN: 2CCS892001R0255
Price
List Price £156.94 ex VAT
Your Price (ex VAT) Save 35%
£102.01 35% OFF
You save £54.93 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £102.01
Trade pricing is personalised to your account

Manufacturer Lead Time

£102.01

Why Choose the ABB S802N-B25 High Performance MCB?

The ABB S802N-B25 is a high-performance 2-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in demanding electrical distribution and industrial control systems. As part of the ABB S800N high-performance circuit breaker series, it combines high fault-current interruption capability with a compact modular design for commercial and industrial applications.

This current-limiting circuit breaker features a Type B tripping characteristic and a rated current of 25 A. Its thermal tripping mechanism provides protection against sustained overloads, while the electromagnetic mechanism responds rapidly to short-circuit faults. The Type B characteristic is particularly suitable for circuits with relatively low starting or inrush currents.

With a breaking capacity of 36 kA, the S802N-B25 provides robust protection in installations where substantial prospective fault currents may occur. Its two-pole configuration enables simultaneous switching and protection across two conductors, while the S800N series' current-limiting design supports rapid and dependable fault interruption.

Key Advantages

  • High-performance 2-pole miniature circuit breaker for demanding electrical installations.
  • 25 A rated current for dependable circuit protection.
  • Type B tripping characteristic suited to circuits with relatively low inrush currents.
  • High 36 kA breaking capacity for installations with substantial prospective fault currents.
  • Thermal overload and electromagnetic short-circuit protection.
  • Current-limiting operation for effective fault-current interruption.

Key Features

  • ABB S800N high-performance MCB series.
  • 2-pole configuration.
  • 25 A rated current.
  • Type B tripping characteristic.
  • 36 kA breaking capacity.
  • Thermal and electromagnetic tripping mechanisms.
  • Current-limiting operation for enhanced short-circuit protection.
  • Modular construction for electrical distribution and industrial control systems.

High-Performance Circuit Protection

The ABB S800N range is engineered for installations requiring compact circuit protection combined with high short-circuit interruption capability. Its thermal trip responds to sustained overload conditions, while the electromagnetic trip provides rapid interruption when severe short-circuit currents occur.

The S802N-B25 combines a 25 A current rating with a Type B trip curve and two-pole construction, making it suitable for distribution and equipment circuits where significant starting currents are not normally expected. Current-limiting operation helps reduce the energy passed through during a fault, supporting the protection of conductors and downstream electrical equipment.

Typical Applications

  • Commercial electrical distribution systems.
  • Industrial distribution and auxiliary circuits.
  • Industrial control panels and switchboards.
  • General-purpose circuits with relatively low inrush currents.
  • Automation and production equipment.
  • Circuits requiring high short-circuit interruption capability.

Technical Specifications

Series S800N
ABB order code 2CCS892001R0255
Product type High-performance miniature circuit breaker (MCB)
Number of poles 2
Rated current 25 A
Tripping characteristic Type B
Breaking capacity 36 kA
Protection function Overload and short-circuit protection
Trip technology Thermal and electromagnetic
Mounting Modular rail mounting

Frequently Asked Questions

What is the ABB S802N-B25 used for?

The S802N-B25 is used to protect electrical circuits against overloads and short circuits in demanding commercial, industrial and electrical distribution applications.

What is the current rating of the S802N-B25?

The ABB S802N-B25 has a rated current of 25 A.

What tripping characteristic does the S802N-B25 use?

The S802N-B25 uses a Type B tripping characteristic, making it suitable for circuits where relatively low starting or inrush currents are expected.

What is the breaking capacity of the ABB S802N-B25?

The S802N-B25 has a breaking capacity of 36 kA, providing high fault-current interruption capability for demanding installations.

How many poles does the S802N-B25 have?

The S802N-B25 is a 2-pole circuit breaker, providing simultaneous switching and protection across two conductors.

Trusted High-Performance Protection from ABB

ABB S800N high-performance miniature circuit breakers provide dependable overload and short-circuit protection for demanding electrical distribution and industrial applications, combining high interruption capability, current limitation and robust modular construction.