2CCS892001R0205 ABB S802N-B20 MCB 36 kA 2P Type B 20 A

2CCS892001R0205 ABB S802N-B20 MCB 36 kA 2P Type B 20 A

ABB S802N-B20 is a 20 A two-pole Type B high-performance miniature circuit breaker with a 36 kA breaking capacity for demanding commercial and industrial circuit protection.

SKU: 2CCS892001R0205Alt SKU: S802NB20MPN: 2CCS892001R0205
Price
List Price £156.94 ex VAT
Your Price (ex VAT) Save 35%
£102.01 35% OFF
You save £54.93 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £102.01
Trade pricing is personalised to your account

Manufacturer Lead Time

£102.01

Why Choose the ABB S802N-B20 Miniature Circuit Breaker?

The ABB S802N-B20 is a high-performance 2-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits in demanding commercial and industrial installations. Part of the proven ABB S800N high-performance circuit breaker series, it combines a rated current of 20 A with a high 36 kA breaking capacity.

Featuring a Type B tripping characteristic, the S802N-B20 is suited to circuits with low to moderate inrush currents, including general-purpose resistive loads and appropriate distribution circuits. Its thermal and electromagnetic tripping mechanisms provide dependable protection against sustained overloads and short-circuit faults, while the current-limiting S800N design supports rapid fault interruption.

The S802N-B20 provides two protected poles in a compact DIN-rail format and is designed for integration into distribution boards, machinery panels and industrial control systems. ABB order code 2CCS892001R0205 identifies this specific 20 A Type B version within the S800N range.

Key Advantages

  • High 36 kA short-circuit breaking capacity for demanding electrical installations.
  • 20 A rated current for commercial and industrial circuit protection.
  • Type B tripping characteristic suited to circuits with low to moderate inrush currents.
  • 2-pole configuration for simultaneous switching and protection.
  • Thermal protection against overloads and electromagnetic protection against short circuits.
  • Current-limiting high-performance design helps reduce fault energy within the protected circuit.

Key Features

  • ABB S800N high-performance MCB series.
  • 2-pole (2P) circuit breaker configuration.
  • 20 A rated current.
  • B-curve tripping characteristic.
  • 36 kA breaking capacity.
  • Thermal and electromagnetic protection mechanisms.
  • Current-limiting circuit breaker construction.
  • Cage terminal connection system.
  • DIN-rail mounting for modular electrical assemblies.
  • Compatible with accessories from the ABB S800 platform.

Reliable High-Performance Circuit Protection

Miniature circuit breakers such as the ABB S802N-B20 automatically disconnect electrical circuits when excessive current results from an overload or short circuit. Thermal tripping responds to sustained overload conditions, while electromagnetic tripping provides rapid interruption of severe short-circuit currents, helping protect conductors and connected equipment.

The S800N series is engineered for applications requiring substantially higher fault-interruption capability than conventional miniature circuit breakers. Its compact modular construction, current-limiting performance and comprehensive accessory compatibility make the S802N-B20 a practical choice for demanding commercial and industrial electrical distribution systems.

Typical Applications

  • Industrial electrical distribution panels.
  • Commercial distribution boards.
  • Machinery and automation control cabinets.
  • General-purpose resistive load circuits.
  • Control and auxiliary power circuits.
  • High fault-level installations requiring high-performance circuit protection.

Technical Specifications

Series S800N
ABB order code 2CCS892001R0205
Product type High-performance miniature circuit breaker (MCB)
Number of poles 2P
Rated current 20 A
Tripping characteristic Type B
Breaking capacity 36 kA
Rated frequency 50/60 Hz
Rated insulation voltage (Ui) 690 V
Rated impulse withstand voltage (Uimp) 8 kV
Protection rating IP20
Pollution degree 3
Terminal type Cage terminal
Mounting type DIN rail
Protection function Overload and short-circuit protection
Standards IEC/EN 60898-1, IEC/EN 60947-2
Dimensions (H × W × D) 95 × 54 × 82.5 mm
Weight approx. 0.49 kg

Frequently Asked Questions

What is the ABB S802N-B20 used for?

The ABB S802N-B20 is used to protect electrical circuits against overload and short-circuit currents in commercial and industrial installations requiring high-performance circuit protection.

What is the rated current of the S802N-B20?

The S802N-B20 has a rated current of 20 A.

What is the breaking capacity of the ABB S802N-B20?

The S802N-B20 provides a high 36 kA breaking capacity for installations where substantial prospective short-circuit currents can occur.

What does the Type B characteristic mean?

The Type B tripping characteristic is suited to circuits with low to moderate temporary inrush currents, including appropriate resistive and general-purpose electrical loads.

How many poles does the ABB S802N-B20 have?

The S802N-B20 is a 2-pole circuit breaker, providing simultaneous switching and protection across two poles.

Trusted High-Performance Protection from ABB

ABB S800 high-performance circuit breakers provide dependable overload and short-circuit protection for demanding commercial and industrial electrical installations, combining high breaking capacities, current-limiting performance and compact modular construction.