2CCS892001R0135 ABB S802N-B13 13A 2P Type B 36kA MCB

2CCS892001R0135 ABB S802N-B13 13A 2P Type B 36kA MCB

ABB S802N-B13 high-performance 13 A two-pole Type B miniature circuit breaker with 36 kA ultimate short-circuit breaking capacity at 415 V AC for overload and short-circuit protection in demanding commercial and industrial electrical installations.

SKU: 2CCS892001R0135Alt SKU: S802NB13MPN: 2CCS892001R0135
Price
List Price £156.94 ex VAT
Your Price (ex VAT) Save 35%
£102.01 35% OFF
You save £54.93 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £102.01
Trade pricing is personalised to your account

Manufacturer Lead Time

£102.01

Why Choose the ABB S802N-B13 High Performance MCB?

The ABB S802N-B13 is a high-performance two-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits where high fault-breaking capability is required. As part of the ABB S800N high-performance circuit breaker series, it provides robust circuit protection for demanding commercial and industrial electrical installations.

The S802N-B13 has a rated current of 13 A and an ultimate short-circuit breaking capacity (Icu) of 36 kA at 415 V AC, with a rated service short-circuit breaking capacity (Ics) of 30 kA at 415 V AC. Its Type B tripping characteristic provides defined overload and short-circuit protection for suitable electrical circuits.

With its two-pole configuration, screw-terminal connection and compact modular construction, the S802N-B13 combines high breaking capacity with dependable circuit protection. ABB order code 2CCS892001R0135 identifies this specific S800N configuration.

Key Advantages

  • High-performance miniature circuit breaker for demanding electrical installations.
  • 13 A rated current for commercial and industrial circuits.
  • 36 kA Icu at 415 V AC for installations with high prospective fault currents.
  • Type B tripping characteristic for defined overload and short-circuit protection.
  • Two protected poles provide simultaneous multi-pole circuit protection.
  • Current-limiting construction and fast arc extinction help reduce the effects of short-circuit faults.

Key Features

  • ABB S800N high-performance MCB series.
  • 13 A rated current.
  • 36 kA ultimate short-circuit breaking capacity (Icu) at 415 V AC.
  • 30 kA service short-circuit breaking capacity (Ics) at 415 V AC.
  • Type B tripping characteristic.
  • Two-pole (2P) configuration with two protected poles.
  • IP20 protection rating.
  • Compliant with IEC/EN 60898-1 and IEC/EN 60947-2.

High-Performance Circuit Protection

The ABB S800N range is designed for the protection and control of electrical circuits against overloads and short circuits where high breaking capacity is required. The S802N-B13 uses thermal protection for sustained overload conditions and electromechanical tripping for short-circuit faults, while its current-limiting design and fast arc extinction help reduce fault energy.

The S802N-B13 combines a 13 A rating, Type B characteristic and 36 kA Icu at 415 V AC in a compact two-pole format. Its high fault-breaking capability makes it particularly suitable for commercial and industrial distribution systems where prospective short-circuit currents can exceed the capabilities of conventional miniature circuit breakers.

Typical Applications

  • Industrial electrical distribution boards.
  • Commercial electrical distribution systems.
  • Machinery and control-panel circuits.
  • Two-pole circuits requiring high fault-breaking capability.
  • Installations requiring selectivity with upstream moulded-case circuit breakers.
  • Back-up protection arrangements for downstream miniature circuit breakers.

Technical Specifications

Series S800N
Product group S800 / S800P / S750 MCB
Part number / SKU S802NB13
ABB order code 2CCS892001R0135
Product type High-performance miniature circuit breaker (MCB)
Rated current 13 A
Number of poles 2
Number of protected poles 2
Tripping characteristic Type B
Ultimate short-circuit breaking capacity (Icu) 36 kA at 415 V AC
Service short-circuit breaking capacity (Ics) 30 kA at 415 V AC
Rated operational voltage 400 V AC according to IEC 60898-1; up to 690 V AC according to IEC 60947-2
Rated insulation voltage (Ui) 690 V
Rated impulse withstand voltage (Uimp) 8 kV
Frequency 50/60 Hz
Terminal type Screw terminal
Tightening torque 3.5 N·m
Protection rating IP20
Operating temperature -25 to +60 °C
Power loss 4 W total; 2 W per pole at rated operating conditions
Standards IEC/EN 60898-1, IEC/EN 60947-2
Width 54 mm
Height 95 mm
Depth 82.5 mm
Approximate unit weight 0.49 kg
EAN / GTIN 7612271203931

Frequently Asked Questions

What is the ABB S802N-B13 used for?

The S802N-B13 is used to protect commercial and industrial electrical circuits against overloads and short circuits, particularly where high breaking capacity and a Type B tripping characteristic are required.

What is the rated current of the ABB S802N-B13?

The ABB S802N-B13 has a rated current of 13 A.

What is the breaking capacity of the S802N-B13?

The S802N-B13 has an ultimate short-circuit breaking capacity (Icu) of 36 kA at 415 V AC and a service short-circuit breaking capacity (Ics) of 30 kA at 415 V AC.

What tripping characteristic does the S802N-B13 use?

The breaker uses a Type B tripping characteristic, providing defined overload and short-circuit protection for suitable commercial and industrial circuits.

How many poles does the ABB S802N-B13 have?

The S802N-B13 is a two-pole (2P) miniature circuit breaker with two protected poles.

Trusted Circuit Protection from ABB

ABB S800 high-performance circuit breakers provide dependable overload and short-circuit protection for demanding commercial and industrial electrical systems, combining high breaking capacity, current-limiting performance and rapid arc extinction in a compact modular design.