2CCS892001R0081 ABB S802N-D8 MCB 36 kA 2P Type D 8 A

2CCS892001R0081 ABB S802N-D8 MCB 36 kA 2P Type D 8 A

ABB S802N-D8 is an 8 A two-pole Type D high-performance miniature circuit breaker with a 36 kA ultimate short-circuit breaking capacity for demanding commercial and industrial circuit protection.

SKU: 2CCS892001R0081Alt SKU: S802ND8MPN: 2CCS892001R0081
Price
List Price £184.32 ex VAT
Your Price (ex VAT) Save 35%
£119.81 35% OFF
You save £64.51 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £119.81
Trade pricing is personalised to your account

Manufacturer Lead Time

£119.81

Why Choose the ABB S802N-D8 Miniature Circuit Breaker?

The ABB S802N-D8 is a high-performance 2-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits where a high breaking capacity is required. Part of the proven ABB S800N high-performance MCB series, it combines a rated current of 8 A with an ultimate short-circuit breaking capacity of 36 kA.

Featuring a Type D tripping characteristic, the S802N-D8 is particularly suited to circuits supplying loads with high inrush currents at switch-on, including motors and transformers. Its thermal and electromagnetic tripping mechanisms provide dependable protection against overload and short-circuit conditions, while the current-limiting S800N design provides rapid fault interruption.

The S802N-D8 provides two protected poles and uses ABB cage terminals for secure conductor connection. Designed for commercial and industrial installations, it can be applied in AC systems up to 400/690 V AC according to the applicable operating conditions and provides a compact solution for demanding distribution boards, machinery and control panels.

Key Advantages

  • High 36 kA ultimate short-circuit breaking capacity for demanding electrical installations.
  • 8 A rated current for commercial and industrial circuit protection.
  • Type D tripping characteristic suited to loads with high starting and inrush currents.
  • 2-pole configuration with both poles protected.
  • Thermal overload and electromagnetic short-circuit protection.
  • Current-limiting design with rapid arc extinction for effective fault interruption.

Key Features

  • ABB S800N high-performance MCB series.
  • 2-pole (2P) circuit breaker configuration.
  • 8 A rated current.
  • D-curve tripping characteristic.
  • 36 kA Icu at 240/415 V AC.
  • Suitable for systems up to 400/690 V AC.
  • 50/60 Hz operating frequency.
  • 690 V rated insulation voltage.
  • Cage terminals for secure electrical connections.
  • Compatible with auxiliary devices and accessories from the ABB S800 platform.

Reliable Protection for High-Inrush Loads

Miniature circuit breakers such as the ABB S802N-D8 automatically disconnect electrical circuits when excessive current results from an overload or short circuit. The combination of thermal overload protection and electromagnetic short-circuit tripping helps protect conductors, equipment and electrical installations while allowing the breaker to be reset after the fault has been cleared.

The S800N D-characteristic range is designed for circuits requiring high breaking capacity and for loads that can produce significant temporary inrush currents during normal switching. This makes the S802N-D8 particularly suitable for demanding commercial and industrial applications involving motors, transformers and other inductive equipment.

Typical Applications

  • Industrial electrical distribution panels.
  • Machinery and automation control cabinets.
  • Motor supply and control circuits.
  • Transformer-fed circuits.
  • Commercial and industrial power distribution systems.
  • Circuits with high starting or inrush currents.

Technical Specifications

Series S800N
ABB order code 2CCS892001R0081
EAN / GTIN 7612271411732
Product type High-performance miniature circuit breaker (MCB)
Number of poles 2P
Number of protected poles 2
Rated current 8 A
Tripping characteristic Type D
Rated ultimate short-circuit breaking capacity (Icu) 36 kA at 240/415 V AC
Rated voltage up to 400/690 V AC
Rated frequency 50/60 Hz
Rated insulation voltage (Ui) 690 V
Protection rating IP20
Pollution degree 3
Terminal type Cage terminal
Mounting type DIN rail
Standards IEC/EN 60898-1, IEC/EN 60947-2
Dimensions (H × W × D) 95 × 54 × 82.5 mm
Weight approx. 0.49 kg

Frequently Asked Questions

What is the ABB S802N-D8 used for?

The ABB S802N-D8 protects electrical circuits against overload and short-circuit currents, particularly in demanding commercial and industrial applications where high breaking capacity and tolerance of high starting currents are required.

What is the rated current of the S802N-D8?

The S802N-D8 has a rated current of 8 A.

What is the breaking capacity of the ABB S802N-D8?

The S802N-D8 provides an ultimate short-circuit breaking capacity of 36 kA at 240/415 V AC.

What does the Type D characteristic mean?

The Type D tripping characteristic is intended for circuits containing loads with relatively high temporary starting or inrush currents, such as motors and transformers.

How many poles does the ABB S802N-D8 have?

The S802N-D8 is a 2-pole circuit breaker with two protected poles for simultaneous circuit protection and switching.

Trusted High-Performance Protection from ABB

ABB S800 high-performance circuit breakers provide dependable overload and short-circuit protection for demanding commercial and industrial installations, combining high breaking capacities, current-limiting performance and compact modular construction.