2CCS891001R0065 ABB S801N-B6 High Performance MCB 36 kA 1P Type B 6 A

2CCS891001R0065 ABB S801N-B6 High Performance MCB 36 kA 1P Type B 6 A

ABB S801N-B6 is a single-pole 6 A B-characteristic high-performance miniature circuit breaker with a 36 kA short-circuit breaking capacity for demanding commercial and industrial circuit protection.

SKU: 2CCS891001R0065Alt SKU: S801NB6MPN: 2CCS891001R0065
Price
List Price £93.44 ex VAT
Your Price (ex VAT) Save 35%
£60.74 35% OFF
You save £32.70 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £60.74
Trade pricing is personalised to your account

Manufacturer Lead Time

£60.74

Why Choose the ABB S801N-B6 High Performance MCB?

The ABB S801N-B6 is a high-performance single-pole miniature circuit breaker (MCB) designed to provide dependable overload and short-circuit protection in demanding electrical distribution systems. As part of the ABB S800N high-performance circuit breaker series, it combines high breaking capacity, effective current limitation and robust construction for commercial and industrial electrical installations.

This circuit breaker features a B tripping characteristic and a rated current of 6 A, making it particularly suitable for circuits with relatively low starting or inrush currents. Thermal tripping provides overload protection, while an electromechanical release provides rapid protection against short-circuit faults.

With a single protected pole and a high short-circuit breaking capacity of 36 kA, the S801N-B6 is designed for installations where substantial prospective fault currents may occur. Its current-limiting operation and rapid arc extinction help reduce let-through fault energy and the associated thermal and mechanical stresses on electrical equipment.

Key Advantages

  • High-performance single-pole miniature circuit breaker for demanding electrical installations.
  • 6 A rated current with B tripping characteristic.
  • High 36 kA short-circuit breaking capacity.
  • B characteristic is suitable for circuits with relatively low starting and inrush currents.
  • Current-limiting design helps reduce thermal and mechanical stresses during short-circuit faults.
  • Thermal and electromechanical releases provide dependable overload and short-circuit protection.

Key Features

  • ABB S800N high-performance MCB series.
  • Single-pole configuration.
  • 6 A rated current.
  • B tripping characteristic.
  • 36 kA short-circuit breaking capacity.
  • Designed for high-performance protection in demanding electrical distribution systems.
  • Thermal overload and electromechanical short-circuit tripping mechanisms.
  • Current-limiting operation helps reduce let-through fault energy.
  • Fast arc extinction supports reliable interruption of high short-circuit currents.
  • Modular construction for integration into electrical distribution and control equipment.

High-Performance Circuit Protection

The ABB S800N range is designed to protect cables, conductors and electrical equipment against overload and short-circuit currents in installations where high breaking performance is required. Thermal overload protection works together with an electromechanical short-circuit release to provide effective protection across different electrical fault conditions.

The B characteristic of the S801N-B6 makes it suitable for circuits with relatively low inrush currents, including many resistive, lighting and general distribution loads. Combined with its 36 kA breaking capacity and current-limiting design, the breaker provides robust protection for demanding commercial and industrial electrical systems.

Typical Applications

  • Industrial electrical distribution systems.
  • Commercial electrical installations.
  • Machinery and automation control panels.
  • General-purpose power and control circuits.
  • Resistive and low-inrush electrical loads.
  • High-fault-level installations requiring single-pole protection.

Technical Specifications

Series S800N
ABB order code 2CCS891001R0065
Product type High-performance miniature circuit breaker (MCB)
Number of poles 1
Rated current 6 A
Tripping characteristic B
Short-circuit breaking capacity 36 kA
Rated impulse withstand voltage (Uimp) 8 kV
Frequency 50–60 Hz
Mounting type DIN rail mounting
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S801N-B6 used for?

The S801N-B6 is a single-pole high-performance miniature circuit breaker designed to protect electrical circuits against overload and short-circuit currents in demanding commercial and industrial installations.

What is the rated current of the S801N-B6?

The ABB S801N-B6 has a rated current of 6 A.

What breaking capacity does the S801N-B6 provide?

The S801N-B6 provides a high short-circuit breaking capacity of 36 kA, making it suitable for installations where substantial prospective fault currents may occur.

What does the B characteristic mean on the S801N-B6?

The B tripping characteristic is intended for circuits with relatively low starting or inrush currents, including many resistive, lighting and general distribution loads.

How many poles does the ABB S801N-B6 have?

The S801N-B6 is a single-pole circuit breaker designed to provide switching and protection for one conductor.

Trusted ABB Circuit Protection

ABB S800 high-performance circuit breakers are designed for dependable overload and short-circuit protection in demanding electrical systems, combining high breaking capacity, effective current limitation and robust modular construction.