2CCS881017R0405 ABB S801U-Z40 1-Pole Z 40A 30kA UL489 High Performance MCB

2CCS881017R0405 ABB S801U-Z40 1-Pole Z 40A 30kA UL489 High Performance MCB

ABB S801U-Z40 is a 1-pole 40 A Z-characteristic high performance miniature circuit breaker with up to 30 kA breaking capacity and UL 489 certification for sensitive overload and short-circuit protection.

SKU: 2CCS881017R0405Alt SKU: S801UZ40MPN: 2CCS881017R0405
Price
List Price £104.88 ex VAT
Your Price (ex VAT) Save 35%
£68.17 35% OFF
You save £36.71 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £68.17
Trade pricing is personalised to your account

Manufacturer Lead Time

£68.17

Why Choose the ABB S801U-Z40 High Performance MCB?

The ABB S801U-Z40 is a compact and highly reliable 1-pole high performance miniature circuit breaker (MCB) designed to protect electrical circuits against overload and short-circuit conditions. As part of the ABB S800U high performance circuit breaker series, it combines a 40 A rated current, Z tripping characteristic and high short-circuit interruption capability for demanding industrial and commercial electrical systems.

The S801U-Z40 uses thermal and electromagnetic tripping mechanisms to provide dependable overcurrent protection. Its Z characteristic provides a sensitive magnetic response, making it particularly suitable for circuits containing electronic equipment, control devices and other loads where rapid disconnection at comparatively low short-circuit currents is required.

With a short-circuit breaking capacity of up to 30 kA and a single-pole configuration, the S801U-Z40 is designed for high-performance branch-circuit protection. Its UL 489 certification and compact DIN-rail format make it suitable for industrial control panels, machinery, automation equipment and electrical distribution systems.

Key Advantages

  • High-performance 1-pole miniature circuit breaker for demanding electrical installations.
  • 40 A rated current for branch and equipment circuit protection.
  • Z tripping characteristic provides sensitive response to overcurrent conditions.
  • High short-circuit breaking capacity of up to 30 kA.
  • UL 489 certified for branch-circuit protection applications.
  • Thermal and electromagnetic tripping provide overload and short-circuit protection.
  • Compact DIN-rail design simplifies integration into control panels and distribution equipment.

Key Features

  • ABB S800U high performance circuit breaker series.
  • 1 protected pole.
  • 40 A rated current.
  • Z tripping characteristic.
  • Breaking capacity up to 30 kA.
  • UL 489 branch-circuit breaker certification.
  • Combined thermal and electromagnetic overcurrent protection.
  • Sensitive tripping characteristic suitable for electronic and control circuits.
  • DIN-rail mounting for convenient panel installation.

Sensitive and Reliable Circuit Protection

High-performance miniature circuit breakers such as the ABB S801U-Z40 automatically disconnect a circuit when excessive current occurs. The thermal tripping mechanism responds to sustained overload conditions, while the electromagnetic mechanism provides rapid interruption during short circuits, helping protect conductors, connected equipment and electrical installations.

The Z characteristic is intended for applications requiring a comparatively sensitive magnetic response. This makes the S801U-Z40 particularly useful for electronic equipment, control circuits and other installations where rapid fault disconnection is important, while its high interruption capability supports use in systems with significant prospective short-circuit currents.

Typical Applications

  • Industrial control panels and switchgear.
  • Electronic equipment and sensitive electrical loads.
  • Automation and process control circuits.
  • Industrial machinery and production equipment.
  • Branch-circuit protection in UL-based installations.
  • Commercial and industrial electrical distribution systems.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Series S800U
SKU S801UZ40
ABB order code 2CCS881017R0405
Product type High performance miniature circuit breaker (MCB)
Number of poles 1
Rated current 40 A
Tripping characteristic Z
Short-circuit breaking capacity up to 30 kA
Protection function Overload and short-circuit protection
Tripping technology Thermal-magnetic
Certification UL 489
Mounting type DIN rail
ABB product group S800 / S800P / S750 MCB

Frequently Asked Questions

What is the ABB S801U-Z40 used for?

The ABB S801U-Z40 is used to protect electrical circuits against overloads and short circuits, particularly in applications requiring a sensitive Z tripping characteristic.

What is the rated current of the S801U-Z40?

The ABB S801U-Z40 has a rated current of 40 A.

What does the Z characteristic mean?

The Z tripping characteristic provides a comparatively sensitive electromagnetic response, making it suitable for electronic equipment, control circuits and other loads requiring rapid protection against relatively low short-circuit currents.

What is the breaking capacity of the ABB S801U-Z40?

The S801U-Z40 provides a short-circuit breaking capacity of up to 30 kA, supporting high-performance protection in demanding electrical installations.

Is the ABB S801U-Z40 UL 489 certified?

Yes. The S801U-Z40 is UL 489 certified for branch-circuit protection in appropriate electrical installations.

Trusted High-Performance Protection from ABB

ABB S800U high performance circuit breakers provide dependable overload and short-circuit protection for demanding electrical systems, combining high interruption capability, application-specific tripping characteristics and compact DIN-rail installation.