Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB S804U-Z40 is a 40 A four-pole Z-characteristic UL 489 miniature circuit breaker with 50 kA short-circuit breaking capacity for sensitive and dependable circuit protection.
£279.64
The ABB S804U-Z40 is a high-performance 4-pole miniature circuit breaker (MCB) designed to provide dependable overload and short-circuit protection in demanding electrical installations. Part of the ABB S800U circuit breaker range, it combines a 40 A rated current, Z tripping characteristic and a high 50 kA short-circuit breaking capacity.
Designed as a UL 489 circuit breaker, the S804U-Z40 is suitable for applications requiring branch-circuit protection to this standard. Its thermal and electromagnetic operating principles provide protection against sustained overload conditions together with rapid interruption of severe short-circuit faults.
The Z characteristic provides a sensitive magnetic response, making the S804U-Z40 particularly useful for circuits and equipment where rapid fault disconnection is required at comparatively low short-circuit current levels. Its 4-pole configuration enables simultaneous protection across four conductors in industrial control, machinery and electrical distribution applications.
The ABB S804U-Z40 combines thermal overload protection with electromagnetic short-circuit protection. Sustained overcurrents operate the thermal release, while short-circuit conditions cause rapid magnetic tripping, helping protect conductors, electrical equipment and downstream components against damaging fault currents.
Its Z characteristic is intended for applications requiring a comparatively sensitive magnetic response. This makes the S804U-Z40 particularly useful for protecting sensitive equipment and circuits where rapid fault interruption is important, while its 50 kA breaking capability provides robust interruption performance under severe short-circuit conditions.
Tick the specs you need, then view products that match.
| Certification | UL 489 | |
|---|---|---|
| Series | S800U | |
| SKU | S804UZ40 | |
| ABB order code | 2CCS864017R0405 | |
| Product type | Miniature circuit breaker (MCB) | |
| Number of poles | 4 | |
| Rated current | 40 A | |
| Tripping characteristic | Z | |
| Short-circuit breaking capacity | 50 kA | |
| Protection functions | Overload and short-circuit protection | |
| Tripping principle | Thermal and electromagnetic | |
| Construction | Current limiting | |
| Standard | UL 489 | |
| Mounting | DIN rail | |
| Product group | S800 / S800P / S750 MCB |
The ABB S804U-Z40 is a 4-pole miniature circuit breaker designed to provide overload and short-circuit protection in demanding electrical applications, including circuits requiring sensitive Z-characteristic protection.
The S804U-Z40 has a rated current of 40 A.
The Z characteristic provides a sensitive magnetic tripping response, making it suitable for circuits and equipment where rapid operation at comparatively low short-circuit current levels is required.
The ABB S804U-Z40 is specified with a short-circuit breaking capacity of 50 kA.
Yes. The S804U-Z40 is specified as a UL 489 circuit breaker for applicable branch-circuit protection installations requiring this standard.
ABB S800U circuit breakers combine high short-circuit interruption capability with dependable overload and magnetic fault protection for demanding industrial control, equipment and electrical distribution applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.