2CCS863017R0705 ABB S803U-Z70 High Performance MCB 50kA 3P Type Z 70A UL489

2CCS863017R0705 ABB S803U-Z70 High Performance MCB 50kA 3P Type Z 70A UL489

ABB S803U-Z70 is a 70 A three-pole Z-characteristic UL 489 high-performance miniature circuit breaker with 50 kA short-circuit breaking capacity for demanding electrical circuit protection.

SKU: 2CCS863017R0705Alt SKU: S803UZ70MPN: 2CCS863017R0705
Price
List Price £340.37 ex VAT
Your Price (ex VAT) Save 35%
£221.24 35% OFF
You save £119.13 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £221.24
Trade pricing is personalised to your account

Manufacturer Lead Time

£221.24

Why Choose the ABB S803U-Z70 High Performance MCB?

The ABB S803U-Z70 is a high-performance three-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in demanding industrial and commercial electrical systems. Part of the ABB S800U high-performance circuit breaker range, this model combines a 70 A rated current, Z tripping characteristic and high 50 kA short-circuit breaking capacity with UL 489 compliance.

The S803U-Z70 uses thermal and electromagnetic tripping mechanisms to protect conductors and connected equipment against sustained overloads and short-circuit faults. Its Z characteristic provides sensitive instantaneous magnetic operation, making it particularly suitable for circuits where rapid response to comparatively low short-circuit currents is required.

With three protected poles and a specified 50 kA short-circuit breaking capacity, the S803U-Z70 provides robust protection where substantial prospective fault currents may occur. Its UL 489 classification supports branch-circuit protection applications, while the ABB order code for this exact breaker is 2CCS863017R0705.

Key Advantages

  • High-performance three-pole miniature circuit breaker for demanding electrical systems.
  • 70 A rated current for three-phase circuit protection.
  • Z tripping characteristic provides sensitive instantaneous magnetic protection.
  • High 50 kA short-circuit breaking capacity.
  • UL 489 design for branch-circuit protection applications.
  • Thermal and electromagnetic tripping provides overload and short-circuit protection.
  • DIN-rail format supports straightforward integration into control and distribution panels.

Key Features

  • ABB S800U high-performance circuit breaker range.
  • 3-pole configuration for three-phase circuit protection.
  • 70 A rated current.
  • Z-characteristic tripping curve.
  • 50 kA short-circuit breaking capacity.
  • UL 489 compliant circuit breaker.
  • Thermal overload and electromagnetic short-circuit protection.
  • 690 V AC rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • ON / OFF / TRIP contact-position indication.
  • DIN-rail mounting for efficient panel installation.

Reliable Protection with a Sensitive Z Characteristic

The ABB S803U-Z70 combines thermal overload protection with sensitive electromagnetic short-circuit protection. The thermal element responds to sustained excessive current, while the magnetic mechanism rapidly disconnects the circuit when fault current reaches the Z-characteristic instantaneous trip range, helping limit electrical stress on conductors and connected equipment.

The Z characteristic is intended for circuits where a relatively sensitive magnetic response is required and substantial normal inrush currents are not expected. Combined with the high fault-interruption capability and UL 489 design of the S800U platform, the S803U-Z70 provides dependable 70 A three-pole protection for demanding electrical installations.

Typical Applications

  • Industrial three-phase electrical distribution.
  • Control and automation installations.
  • Circuits requiring sensitive Z-characteristic protection.
  • Industrial control panels and switchboards.
  • Commercial electrical distribution systems.
  • UL 489 branch-circuit protection applications.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Series S800U
ABB order code 2CCS863017R0705
Product type High-performance miniature circuit breaker (MCB)
Number of poles 3
Protected poles 3
Rated current 70 A
Tripping characteristic Z
Short-circuit breaking capacity 50 kA
Rated insulation voltage 690 V AC
Rated impulse withstand voltage 8 kV
Trip mechanism Thermal-magnetic
Standard UL 489
Mounting DIN rail

Frequently Asked Questions

What is the ABB S803U-Z70 used for?

The S803U-Z70 is a three-pole high-performance MCB used to protect electrical circuits against overload and short-circuit currents, particularly where a sensitive Z-characteristic magnetic response is required.

What is the current rating of the S803U-Z70?

The ABB S803U-Z70 has a rated current of 70 A.

What does the Z characteristic mean?

The Z tripping characteristic provides comparatively sensitive instantaneous magnetic operation, making it suitable for circuits where rapid response to lower levels of short-circuit current is required.

Does the ABB S803U-Z70 comply with UL 489?

Yes. The S803U-Z70 is a UL 489 circuit breaker designed for applicable branch-circuit protection requirements.

What is the ABB order code for the S803U-Z70?

The ABB order code for the S803U-Z70 is 2CCS863017R0705.

Trusted High-Performance Protection from ABB

ABB S800U high-performance circuit breakers provide dependable overload and short-circuit protection for demanding industrial and commercial electrical systems, combining high fault-current interruption capability with specialised tripping characteristics for different circuit-protection requirements.