2CCS863002R1467 ABB S803S-UCK16-R High Performance MCB 50kA 3P Type K 16A

2CCS863002R1467 ABB S803S-UCK16-R High Performance MCB 50kA 3P Type K 16A

ABB S803S-UCK16-R is a 16 A three-pole Type K high-performance miniature circuit breaker with 50 kA short-circuit breaking capacity for demanding industrial circuit protection.

SKU: 2CCS863002R1467Alt SKU: S803SUCK16RMPN: 2CCS863002R1467
Price
List Price £385.81 ex VAT
Your Price (ex VAT) Save 35%
£250.78 35% OFF
You save £135.03 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £250.78
Trade pricing is personalised to your account

Manufacturer Lead Time

£250.78

Why Choose the ABB S803S-UCK16-R High Performance MCB?

The ABB S803S-UCK16-R is a high-performance three-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in demanding industrial electrical systems. Part of the ABB S800S high-performance MCB series, this model combines a 16 A rated current, K tripping characteristic and high 50 kA short-circuit breaking capacity for robust circuit protection.

The S803S-UCK16-R uses thermal and electromagnetic tripping mechanisms to protect conductors and connected equipment against sustained overloads and short-circuit faults. Its K characteristic is particularly suitable for circuits supplying motors, transformers and other inductive loads where comparatively high starting currents need to be accommodated without unnecessary tripping.

With three protected poles and a specified 50 kA short-circuit breaking capacity, the S803S-UCK16-R is engineered for installations where high prospective fault currents may occur. The -R ring-terminal connection version supports secure electrical termination, while the ABB order code for this exact breaker is 2CCS863002R1467.

Key Advantages

  • High-performance three-pole miniature circuit breaker for demanding electrical installations.
  • 16 A rated current for three-phase circuit protection.
  • K tripping characteristic suited to motors, transformers and inductive loads.
  • High 50 kA short-circuit breaking capacity.
  • Thermal and electromagnetic tripping provides overload and short-circuit protection.
  • Ring-terminal connection design supports secure electrical termination.
  • DIN-rail format simplifies integration into industrial distribution and control panels.

Key Features

  • ABB S800S high-performance MCB series.
  • 3-pole configuration with all three poles protected.
  • 16 A rated current.
  • Type K / K-characteristic tripping curve.
  • 50 kA short-circuit breaking capacity.
  • Thermal overload and electromagnetic short-circuit tripping.
  • 690 V AC rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • IP20 protection rating.
  • ON / OFF / TRIP contact-position indication.
  • Suitable for 35 mm DIN-rail mounting.

Reliable Protection for Motor and Inductive Circuits

The ABB S803S-UCK16-R combines thermal overload protection with rapid electromagnetic short-circuit protection. The thermal mechanism responds to sustained excessive current, while the magnetic trip mechanism rapidly disconnects the circuit during severe fault conditions, helping protect conductors, machinery and connected electrical equipment.

The K tripping characteristic accommodates the starting currents commonly associated with motors, transformers and other inductive equipment while maintaining effective fault protection. Combined with the high fault-interruption capability of the S800S platform, the S803S-UCK16-R is well suited to industrial circuits requiring dependable 16 A three-pole protection.

Typical Applications

  • Industrial three-phase electrical distribution systems.
  • Motor supply and machinery circuits.
  • Transformer and inductive-load circuits.
  • Industrial control panels and switchboards.
  • Manufacturing and production equipment.
  • Automation and material-handling systems.

Technical Specifications

Series S800S
ABB order code 2CCS863002R1467
Product type High-performance miniature circuit breaker (MCB)
Number of poles 3
Protected poles 3
Rated current 16 A
Tripping characteristic K
Short-circuit breaking capacity 50 kA
Rated insulation voltage 690 V AC
Rated impulse withstand voltage 8 kV
Protection rating IP20
Ambient operating temperature -25 to +60 °C
Connection type Ring-terminal connection
Mounting 35 mm DIN rail

Frequently Asked Questions

What is the ABB S803S-UCK16-R used for?

The S803S-UCK16-R is a high-performance three-pole MCB used to protect electrical circuits against overload and short-circuit currents, including circuits supplying motors, transformers and other inductive loads.

What is the current rating of the S803S-UCK16-R?

The ABB S803S-UCK16-R has a rated current of 16 A.

What does the K characteristic mean?

The K tripping characteristic accommodates comparatively high starting currents, making the breaker suitable for motors, transformers and other inductive equipment.

What is the breaking capacity of the S803S-UCK16-R?

The ABB S803S-UCK16-R has a specified short-circuit breaking capacity of 50 kA.

What is the ABB order code for the S803S-UCK16-R?

The ABB order code for the S803S-UCK16-R is 2CCS863002R1467.

Trusted High-Performance Protection from ABB

ABB S800S high-performance miniature circuit breakers provide dependable overload and short-circuit protection for demanding industrial electrical systems where robust performance, high fault-current interruption capability and reliable protection of connected equipment are required.