2CCS863002R0104 ABB S803S-C10-R 3-Pole Type C 10 A 50 kA High-Performance MCB

2CCS863002R0104 ABB S803S-C10-R 3-Pole Type C 10 A 50 kA High-Performance MCB

ABB S803S-C10-R is a 10 A three-pole Type C high-performance miniature circuit breaker with 50 kA short-circuit breaking capacity for demanding industrial three-phase circuit protection.

SKU: 2CCS863002R0104Alt SKU: S803SC10RMPN: 2CCS863002R0104
Price
List Price £251.39 ex VAT
Your Price (ex VAT) Save 35%
£163.40 35% OFF
You save £87.99 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £163.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£163.40

Why Choose the ABB S803S-C10-R High-Performance MCB?

The ABB S803S-C10-R is a high-performance three-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits in demanding industrial power distribution systems. As part of the ABB S800S high-performance circuit breaker series, it combines a 10 A rated current, Type C tripping characteristic and a high 50 kA short-circuit breaking capacity.

The Type C characteristic provides a practical balance between dependable fault protection and tolerance of moderate starting or inrush currents. This makes the S803S-C10-R suitable for a broad range of industrial loads, machinery circuits and distribution applications. Thermal and electromagnetic tripping mechanisms provide protection against both sustained overload conditions and high-current short-circuit faults.

Its three-pole construction enables coordinated protection and switching of three-phase circuits. The S803S-C10-R is designed for professional industrial distribution, machinery and control-panel applications where robust construction, high fault-current capability and reliable overcurrent protection are required.

Key Advantages

  • High-performance three-pole miniature circuit breaker for demanding industrial installations.
  • 10 A rated current for three-phase equipment and control circuits.
  • Type C tripping characteristic suited to circuits with moderate starting and inrush currents.
  • High 50 kA short-circuit breaking capacity.
  • Thermal protection helps safeguard conductors and equipment against sustained overloads.
  • Electromagnetic protection provides rapid interruption of severe short-circuit faults.
  • Three protected poles provide coordinated protection for three-phase circuits.
  • Part of ABB's established S800S high-performance MCB range.

Key Features

  • ABB S800S high-performance MCB series.
  • 3-pole configuration for three-phase circuit protection.
  • 10 A rated current.
  • Type C tripping characteristic.
  • 50 kA rated ultimate short-circuit breaking capacity.
  • Thermal and electromagnetic overcurrent protection.
  • 690 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • ON / OFF / TRIP contact-position indication.
  • Interchangeable cage-terminal S800 design.
  • DIN-rail mounting for industrial distribution and control assemblies.

Reliable Protection for Three-Phase Industrial Circuits

High-performance miniature circuit breakers such as the ABB S803S-C10-R automatically disconnect electrical circuits when current exceeds permitted operating limits. The thermal element responds to sustained overload conditions, while the electromagnetic mechanism rapidly interrupts high-current short circuits to help protect conductors, connected equipment and electrical distribution infrastructure.

The Type C characteristic accommodates moderate transient starting currents while maintaining dependable short-circuit protection. Combined with the S800S platform's 50 kA breaking capacity and three-pole construction, the S803S-C10-R provides robust protection for demanding three-phase industrial electrical systems.

Typical Applications

  • Industrial three-phase electrical distribution systems.
  • Machinery and automation control panels.
  • Industrial equipment with moderate starting currents.
  • Control and auxiliary circuits.
  • Manufacturing and production equipment.
  • Installations requiring high short-circuit breaking capacity.

Technical Specifications

Series S800S
ABB order code 2CCS863002R0104
Product type High-performance miniature circuit breaker (MCB)
Number of poles 3
Number of protected poles 3
Rated current 10 A
Tripping characteristic Type C
Rated ultimate short-circuit breaking capacity (Icu) 50 kA
Rated insulation voltage (Ui) 690 V
Rated impulse withstand voltage (Uimp) 8 kV
Frequency 50/60 Hz
Tripping mechanism Thermal / electromagnetic
Contact position indication ON / OFF / TRIP
Mounting type DIN rail
Terminal type Interchangeable cage terminal
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S803S-C10-R used for?

The S803S-C10-R is a three-pole high-performance miniature circuit breaker designed to protect industrial three-phase electrical circuits against overloads and short circuits.

What is the rated current of the ABB S803S-C10-R?

The S803S-C10-R has a rated current of 10 A.

What breaking capacity does the S803S-C10-R provide?

The S803S-C10-R provides a rated ultimate short-circuit breaking capacity of 50 kA, making it suitable for demanding installations with high prospective fault currents.

What does the Type C characteristic mean?

The Type C tripping characteristic accommodates moderate starting and inrush currents while providing dependable overload and short-circuit protection, making it suitable for many industrial and inductive loads.

How is the ABB S803S-C10-R installed?

The S803S-C10-R is designed for DIN-rail mounting in suitable industrial control panels, distribution boards and electrical enclosures.

Trusted High-Performance Protection from ABB

ABB S800S high-performance miniature circuit breakers provide dependable overload and short-circuit protection for demanding industrial electrical systems where high breaking capacity, robust construction and reliable three-phase circuit protection are required.