2CCS863001R0205 ABB S803S-B20 20 A 3-Pole Type B 50 kA MCB

2CCS863001R0205 ABB S803S-B20 20 A 3-Pole Type B 50 kA MCB

ABB S803S-B20 is a 20 A three-pole Type B high-performance miniature circuit breaker with 50 kA short-circuit breaking capacity for demanding industrial and commercial circuit protection.

SKU: 2CCS863001R0205Alt SKU: S803SB20MPN: 2CCS863001R0205
Price
List Price £251.39 ex VAT
Your Price (ex VAT) Save 35%
£163.40 35% OFF
You save £87.99 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £163.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£163.40

Why Choose the ABB S803S-B20 High-Performance MCB?

The ABB S803S-B20 is a high-performance three-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits in demanding industrial and commercial installations. Part of the established ABB S800S high-performance circuit breaker series, it combines a 20 A rated current with a powerful 50 kA short-circuit breaking capacity.

Featuring a Type B tripping characteristic, the S803S-B20 provides sensitive magnetic fault protection and is particularly suited to circuits with relatively low starting or inrush currents. Its thermal-magnetic operating principle provides dependable protection against sustained overloads and rapid disconnection during short-circuit conditions.

With its three-pole configuration, 20 A rated current and 50 kA breaking capacity, the S803S-B20 provides robust protection for three-phase distribution, control and equipment circuits. Its modular construction enables straightforward integration into electrical distribution boards and industrial control assemblies.

Key Advantages

  • High-performance three-pole miniature circuit breaker for demanding circuit protection.
  • 20 A rated current for industrial and commercial electrical circuits.
  • High 50 kA short-circuit breaking capacity for installations with substantial prospective fault currents.
  • Type B tripping characteristic for sensitive protection of circuits with relatively low inrush currents.
  • Provides dependable overload and short-circuit protection.
  • Three-pole construction provides simultaneous protection for three-phase circuits.

Key Features

  • ABB S800S high-performance circuit breaker series.
  • 20 A rated current.
  • 3-pole configuration.
  • Type B tripping characteristic.
  • 50 kA short-circuit breaking capacity.
  • Thermal-magnetic overload and short-circuit protection.
  • Suitable for circuits with relatively low starting and inrush currents.
  • Designed for demanding commercial and industrial electrical installations.

High-Performance Protection for Three-Phase Circuits

High-performance circuit breakers such as the ABB S803S-B20 automatically disconnect electrical circuits when excessive current results from overload or short-circuit conditions. Thermal protection responds to sustained overload currents, while magnetic protection provides rapid interruption when severe fault currents occur.

The Type B characteristic provides sensitive magnetic operation and is particularly suited to circuits that do not normally experience substantial starting currents. Combined with its 50 kA breaking capacity, the S803S-B20 provides dependable protection for demanding three-phase distribution, control and industrial electrical applications.

Typical Applications

  • Three-phase industrial electrical distribution systems.
  • Industrial control and auxiliary circuits.
  • Resistive and low-inrush electrical loads.
  • Commercial and industrial switchboards.
  • Automation and manufacturing installations.
  • Circuits requiring high short-circuit breaking capacity.

Technical Specifications

Series S800S
ABB order code 2CCS863001R0205
Product type High-performance miniature circuit breaker (MCB)
Rated current 20 A
Number of poles 3
Tripping characteristic Type B
Short-circuit breaking capacity 50 kA
Protection function Overload and short-circuit protection
Standard IEC/EN 60947-2
Mounting type DIN rail

Frequently Asked Questions

What is the ABB S803S-B20 used for?

The ABB S803S-B20 is used to protect three-phase industrial and commercial electrical circuits against overloads and short circuits, particularly where high breaking capacity and a Type B characteristic are required.

What is the rated current of the S803S-B20?

The circuit breaker has a rated current of 20 A.

What breaking capacity does the S803S-B20 provide?

The S803S-B20 provides a short-circuit breaking capacity of 50 kA.

What does the Type B characteristic mean?

The Type B tripping characteristic provides sensitive magnetic fault protection and is suited to circuits with relatively low starting or inrush currents.

How many poles does the ABB S803S-B20 have?

The S803S-B20 is a three-pole high-performance miniature circuit breaker suitable for protecting three-phase electrical circuits.

Trusted High-Performance Circuit Protection from ABB

ABB S800S high-performance circuit breakers provide dependable overload and short-circuit protection for demanding industrial and commercial electrical installations, combining high breaking capacity with robust protection for modern power distribution systems.