2CCS863001R0134 ABB S803S-C13 13 A 3-Pole Type C 50 kA MCB

2CCS863001R0134 ABB S803S-C13 13 A 3-Pole Type C 50 kA MCB

ABB S803S-C13 is a 13 A three-pole Type C high-performance miniature circuit breaker with 50 kA short-circuit breaking capacity for demanding industrial and commercial circuit protection.

SKU: 2CCS863001R0134Alt SKU: S803SC13MPN: 2CCS863001R0134
Price
List Price £251.39 ex VAT
Your Price (ex VAT) Save 35%
£163.40 35% OFF
You save £87.99 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £163.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£163.40

Why Choose the ABB S803S-C13 High-Performance MCB?

The ABB S803S-C13 is a high-performance three-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits in demanding industrial and commercial installations. Part of the established ABB S800S high-performance circuit breaker series, it combines a 13 A rated current with a powerful 50 kA short-circuit breaking capacity.

Featuring a Type C tripping characteristic, the S803S-C13 is well suited to general industrial circuits and loads that can produce moderate starting or inrush currents. Its thermal-magnetic operating principle provides dependable overload and short-circuit protection while accommodating normal transient currents associated with many types of machinery and electrical equipment.

With its three-pole configuration, 13 A rated current and 50 kA breaking capacity, the S803S-C13 provides robust protection for three-phase distribution, machinery and industrial control circuits. Its modular construction enables straightforward integration into electrical distribution boards and control assemblies.

Key Advantages

  • High-performance three-pole miniature circuit breaker for demanding circuit protection.
  • 13 A rated current for industrial distribution and equipment circuits.
  • High 50 kA short-circuit breaking capacity for installations with substantial prospective fault currents.
  • Type C tripping characteristic suited to general-purpose loads with moderate inrush currents.
  • Provides dependable overload and short-circuit protection.
  • Three-pole construction provides simultaneous protection for three-phase circuits.

Key Features

  • ABB S800S high-performance circuit breaker series.
  • 13 A rated current.
  • 3-pole configuration.
  • Type C tripping characteristic.
  • 50 kA short-circuit breaking capacity.
  • Thermal-magnetic overload and short-circuit protection.
  • Suitable for industrial circuits with moderate starting currents.
  • Designed for demanding commercial and industrial electrical installations.

High-Performance Protection for Three-Phase Circuits

High-performance circuit breakers such as the ABB S803S-C13 automatically disconnect electrical circuits when excessive current results from overload or short-circuit conditions. Thermal protection responds to sustained overload currents, while magnetic protection provides rapid interruption during severe short-circuit faults.

The Type C characteristic offers a practical balance between fault sensitivity and tolerance of normal starting currents, making the S803S-C13 suitable for a broad range of industrial loads. Combined with its 50 kA breaking capacity, it provides dependable protection for demanding three-phase distribution and machinery applications.

Typical Applications

  • Three-phase industrial electrical distribution systems.
  • Machinery and production equipment.
  • Industrial control and power circuits.
  • Commercial and industrial switchboards.
  • Automation and manufacturing installations.
  • Circuits requiring high short-circuit breaking capacity.

Technical Specifications

Series S800S
ABB order code 2CCS863001R0134
Product type High-performance miniature circuit breaker (MCB)
Rated current 13 A
Number of poles 3
Tripping characteristic Type C
Short-circuit breaking capacity 50 kA
Protection function Overload and short-circuit protection
Standard IEC/EN 60947-2
Mounting type DIN rail

Frequently Asked Questions

What is the ABB S803S-C13 used for?

The ABB S803S-C13 is used to protect three-phase industrial and commercial electrical circuits against overloads and short circuits, particularly where high breaking capacity is required.

What is the rated current of the S803S-C13?

The circuit breaker has a rated current of 13 A.

What breaking capacity does the S803S-C13 provide?

The S803S-C13 provides a short-circuit breaking capacity of 50 kA.

What does the Type C characteristic mean?

The Type C tripping characteristic is suited to general-purpose circuits and equipment with moderate starting or inrush currents, providing effective overload and short-circuit protection.

How many poles does the ABB S803S-C13 have?

The S803S-C13 is a three-pole high-performance miniature circuit breaker suitable for protecting three-phase electrical circuits.