2CCS862017R0705 ABB S802U-Z70 2-Pole Z 70 A 50 kA High-Performance MCB

2CCS862017R0705 ABB S802U-Z70 2-Pole Z 70 A 50 kA High-Performance MCB

ABB S802U-Z70 is a 70 A two-pole Z characteristic high-performance miniature circuit breaker with a 50 kA UL 489 interrupting rating for demanding commercial and industrial circuit protection.

SKU: 2CCS862017R0705Alt SKU: S802UZ70MPN: 2CCS862017R0705
Price
List Price £240.65 ex VAT
Your Price (ex VAT) Save 35%
£156.42 35% OFF
You save £84.23 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £156.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£156.42

Why Choose the ABB S802U-Z70 High-Performance MCB?

The ABB S802U-Z70 is a high-performance two-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits where a high breaking capacity is required. As part of the ABB S800U high-performance circuit breaker series, it combines a 70 A rated current, Z tripping characteristic and robust protection for demanding commercial and industrial electrical distribution systems.

Designed to meet UL 489, CSA C22.2 No.5 and IEC/EN 60947-2 requirements, the S802U-Z70 provides a 50 kA interrupting rating at 240 V AC according to UL 489. Its two-pole configuration provides coordinated protection and switching, while the sensitive Z characteristic is intended for circuits where rapid magnetic tripping is required to protect sensitive equipment.

The S802U-Z70 also provides a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC according to IEC/EN 60947-2. Its combination of high breaking capacity, 70 A current rating and industrial-grade S800U construction makes it suitable for demanding electrical panels, machinery and power distribution applications.

Key Advantages

  • High-performance two-pole miniature circuit breaker for demanding circuit protection.
  • 70 A rated current for industrial and commercial distribution circuits.
  • Z tripping characteristic provides sensitive magnetic protection for circuits requiring rapid fault interruption.
  • 50 kA UL 489 interrupting rating at 240 V AC.
  • 50 kA ultimate short-circuit breaking capacity at 415 V AC according to IEC/EN 60947-2.
  • Two-pole construction provides coordinated switching and overcurrent protection.
  • High-performance S800U platform designed for installations with demanding prospective fault currents.
  • Compliance with UL, CSA and IEC/EN standards supports use in international industrial applications.

Key Features

  • ABB S800U high-performance MCB series.
  • 2-pole configuration.
  • 70 A rated current.
  • Z tripping characteristic.
  • 50 kA UL 489 interrupting rating.
  • 240 V AC rated voltage according to UL 489.
  • 415 V AC rated operational voltage according to IEC 60947-2.
  • 50 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • 690 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • 4.9 W power loss.
  • Interchangeable cage-terminal S800U design.

Reliable High-Performance Circuit Protection

Miniature circuit breakers such as the ABB S802U-Z70 automatically disconnect a circuit when overload or short-circuit conditions exceed permitted limits. Thermal overload protection and rapid electromagnetic short-circuit protection help safeguard cables, connected equipment and electrical distribution infrastructure while providing a resettable protective solution.

The S800U series is engineered for commercial and industrial applications requiring high breaking capacity. The S802U-Z70 combines this capability with a sensitive Z characteristic, making it particularly useful where rapid magnetic fault protection is required for sensitive electrical and electronic loads.

Typical Applications

  • Industrial electrical distribution systems.
  • Commercial power distribution panels.
  • Machinery and automation control panels.
  • Protection of sensitive electrical and electronic equipment.
  • Branch circuits requiring UL 489 circuit-breaker protection.
  • Installations with high prospective short-circuit currents.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Series S800U
ABB order code 2CCS862017R0705
EAN 7612271214814
Product type High-performance miniature circuit breaker (MCB)
Number of poles 2
Rated current 70 A
Tripping characteristic Z
Rated voltage according to UL 489 240 V AC
Rated operational voltage according to IEC 60947-2 415 V AC
UL 489 interrupting rating 50 kA
Rated ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Rated insulation voltage (Ui) 690 V
Rated impulse withstand voltage (Uimp) 8 kV
Input voltage type AC
Frequency 50/60 Hz
Power loss 4.9 W
Standards UL 489; CSA C22.2 No.5; IEC/EN 60947-2
Weight approx. 0.49 kg

Frequently Asked Questions

What is the ABB S802U-Z70 used for?

The S802U-Z70 is a two-pole high-performance miniature circuit breaker designed to protect industrial and commercial electrical circuits against overloads and short circuits.

What is the rated current of the ABB S802U-Z70?

The S802U-Z70 has a rated current of 70 A.

What breaking capacity does the S802U-Z70 provide?

The breaker provides a 50 kA interrupting rating at 240 V AC according to UL 489 and a 50 kA rated ultimate short-circuit breaking capacity at 415 V AC according to IEC/EN 60947-2.

What does the Z tripping characteristic mean?

The Z characteristic provides sensitive magnetic tripping, making the S802U-Z70 suitable for circuits where rapid fault interruption is required to protect sensitive electrical and electronic equipment.

Which standards apply to the ABB S802U-Z70?

The S802U-Z70 is specified to UL 489, CSA C22.2 No.5 and IEC/EN 60947-2.

Trusted High-Performance Protection from ABB

ABB S800U high-performance miniature circuit breakers provide dependable overload and short-circuit protection for demanding commercial and industrial electrical distribution systems where high breaking capacity and robust circuit protection are required.