2CCS862002R1447 ABB S802S-UCK13-R High Performance MCB 50kA 2P Type K 13A

2CCS862002R1447 ABB S802S-UCK13-R High Performance MCB 50kA 2P Type K 13A

ABB S802S-UCK13-R is a 13 A two-pole UC-K high-performance miniature circuit breaker with a maximum 50 kA breaking capacity at 500 V DC and ring terminal connections for demanding industrial DC circuit protection.

SKU: 2CCS862002R1447Alt SKU: S802SUCK13RMPN: 2CCS862002R1447
Price
List Price £263.75 ex VAT
Your Price (ex VAT) Save 35%
£171.44 35% OFF
You save £92.31 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £171.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£171.44

Why Choose the ABB S802S-UCK13-R High Performance MCB?

The ABB S802S-UCK13-R is a high-performance 2-pole miniature circuit breaker (MCB) designed for demanding DC circuit protection. As part of the ABB S800 high-performance circuit breaker range, it combines a 13 A rated current, UC-K tripping characteristic and high 50 kA breaking capacity for industrial electrical systems requiring robust overload and short-circuit protection.

The S802S-UCK13-R is a current-limiting device with separate thermal and electromechanical tripping mechanisms. The thermal release provides overload protection, while the electromechanical release responds to short-circuit conditions. Its UC-K characteristic is suitable for circuits where elevated starting or inrush currents may occur during normal operation.

With a rated current of 13 A, a UC-K tripping characteristic and a maximum breaking capacity of 50 kA at 500 V DC, the S802S-UCK13-R provides high-performance protection for demanding DC applications. This ring-terminal version offers secure conductor termination and forms part of ABB's industrial S800S circuit protection platform.

Key Advantages

  • High-performance 2-pole miniature circuit breaker for demanding DC applications.
  • 13 A rated current with UC-K tripping characteristic.
  • Maximum 50 kA breaking capacity at 500 V DC.
  • Suitable for DC operating voltages up to 500 V DC.
  • Separate thermal overload and electromechanical short-circuit tripping mechanisms.
  • Current-limiting design helps reduce fault energy and stress on connected equipment.
  • Ring terminal connection for secure conductor termination.
  • Designed for demanding industrial electrical protection applications.

Key Features

  • ABB S800 / S802S high-performance MCB range.
  • 2-pole configuration.
  • 13 A rated current.
  • UC-K tripping characteristic.
  • 50 kA maximum breaking capacity at 500 V DC.
  • Current-limiting circuit breaker design.
  • Thermal tripping mechanism for overload protection.
  • Electromechanical tripping mechanism for short-circuit protection.
  • Ring terminal connection.
  • Designed for industrial DC circuit protection.
  • Complies with IEC/EN 60947-2.
  • Wide range of compatible S800 accessories.

High-Performance Protection for Demanding DC Circuits

The ABB S802S-UCK13-R protects electrical conductors and connected equipment against damaging overload and short-circuit conditions in demanding DC systems. Its thermal release responds to sustained overload conditions, while the electromechanical release provides rapid operation when a short circuit occurs.

The UC-K characteristic is suited to applications where elevated functional peak or starting currents can occur. Combined with a maximum breaking capacity of 50 kA at 500 V DC, the S802S-UCK13-R provides robust circuit protection for industrial DC distribution, control equipment, machinery and other applications where high prospective fault currents may be present.

Typical Applications

  • Industrial DC electrical distribution systems.
  • DC machinery and automation circuits.
  • Industrial control and auxiliary circuits.
  • Circuits with elevated starting or inrush currents.
  • DC switchboards and distribution equipment.
  • Industrial equipment protection.
  • Applications requiring high DC short-circuit breaking capacity.

Technical Specifications

Series S800 / S802S
ABB order code 2CCS862002R1447
Product type High-performance miniature circuit breaker (MCB)
Number of poles 2
Rated current 13 A
Tripping characteristic UC-K / Type K
Maximum breaking capacity 50 kA at 500 V DC
Maximum operating voltage 500 V DC
Protection function Overload and short-circuit protection
Overload release Thermal tripping mechanism
Short-circuit release Electromechanical tripping mechanism
Terminal version Ring terminal connection
Standard IEC/EN 60947-2
Application Industrial DC circuit protection
Weight approx. 0.49 kg
EAN 7612271210663
Product group S800 / S800P / S750 MCB

Frequently Asked Questions

What is the ABB S802S-UCK13-R used for?

The ABB S802S-UCK13-R is a high-performance circuit breaker designed to provide overload and short-circuit protection for demanding industrial DC circuits, including applications where elevated starting or inrush currents can occur.

What is the rated current of the S802S-UCK13-R?

The S802S-UCK13-R has a rated current of 13 A and uses a UC-K / Type K tripping characteristic.

What is the breaking capacity of the ABB S802S-UCK13-R?

The S802S-UCK13-R has a maximum breaking capacity of 50 kA at 500 V DC, providing high-performance protection for demanding DC electrical systems.

How does the ABB S802S-UCK13-R provide circuit protection?

The S802S-UCK13-R uses a thermal tripping mechanism for overload protection and an electromechanical tripping mechanism for short-circuit protection.

What connection type does the ABB S802S-UCK13-R use?

The S802S-UCK13-R uses a ring terminal connection, providing secure conductor termination for demanding industrial DC circuit protection applications.

Trusted Industrial Circuit Protection from ABB

ABB S800 high-performance circuit breakers are engineered for demanding industrial electrical protection applications, combining high breaking capacity, current-limiting performance and dependable overload and short-circuit protection for DC distribution, machinery, control and equipment circuits.