2CCS862002R0081 ABB S802S-D8-R MCB 50 kA 2P Type D 8 A

2CCS862002R0081 ABB S802S-D8-R MCB 50 kA 2P Type D 8 A

ABB S802S-D8-R is an 8 A two-pole Type D high-performance miniature circuit breaker with ring-terminal connections and 50 kA ultimate short-circuit breaking capacity for demanding commercial and industrial circuit protection.

SKU: 2CCS862002R0081Alt SKU: S802SD8RMPN: 2CCS862002R0081
Price
List Price £206.34 ex VAT
Your Price (ex VAT) Save 35%
£134.12 35% OFF
You save £72.22 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £134.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£134.12

Why Choose the ABB S802S-D8-R Miniature Circuit Breaker?

The ABB S802S-D8-R is a high-performance 2-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits where high breaking capacity is required. Part of the ABB S800S series, this version features ring-terminal connections and a Type D tripping characteristic for demanding commercial and industrial applications.

With a rated current of 8 A and an ultimate short-circuit breaking capacity (Icu) of 50 kA, the S802S-D8-R provides robust protection in installations with substantial prospective fault currents. Its Type D characteristic is intended for circuits supplying loads with high inrush current at circuit closing, such as motors and LV/LV transformers.

The S802S-D8-R combines high fault-interruption capability with a current-limiting design and a 2-pole configuration. It is also suitable where selectivity with an upstream moulded-case circuit breaker or back-up protection for downstream miniature circuit breakers forms part of the electrical protection design.

Key Advantages

  • High-performance 50 kA Icu miniature circuit breaker.
  • 8 A rated current for lower-current equipment and distribution circuits.
  • Type D tripping characteristic for loads with high inrush current.
  • 2-pole configuration for coordinated circuit protection.
  • Ring-terminal connection version of the ABB S800S range.
  • Protects circuits against both overloads and short circuits.
  • Suitable for demanding commercial and industrial applications.

Key Features

  • ABB S800S high-performance MCB series.
  • 8 A rated current.
  • Type D tripping characteristic.
  • 2-pole configuration.
  • 50 kA ultimate short-circuit breaking capacity (Icu).
  • Ring-terminal connection design.
  • Suitable for circuits supplying high-inrush loads.
  • Designed for overload and short-circuit protection and control.

High-Performance Protection for High-Inrush Loads

The ABB S802S-D8-R is designed for protection and control of circuits against overloads and short circuits where a high breaking capacity is required. Its Type D characteristic makes it particularly suitable for appropriately designed circuits supplying loads that draw substantial inrush current when energised, including motors and LV/LV transformers.

With its 8 A current rating, 2-pole construction and 50 kA Icu, the S802S-D8-R provides robust protection for demanding electrical installations. The S800S range can also be applied where selectivity with an MCCB or back-up protection for downstream MCBs is required as part of a coordinated protection system.

Typical Applications

  • Industrial electrical distribution systems.
  • Commercial electrical installations.
  • Motor and machinery circuits.
  • LV/LV transformer circuits.
  • Automation and industrial control panels.
  • Circuits supplying loads with high starting or inrush currents.
  • Installations requiring high short-circuit breaking capacity.

Technical Specifications

Series S800S
SKU S802SD8R
ABB order code 2CCS862002R0081
Product group S800 / S800P / S750 MCB
Product type High-performance miniature circuit breaker (MCB)
Rated current 8 A
Number of poles 2
Tripping characteristic Type D
Ultimate short-circuit breaking capacity (Icu) 50 kA
Connection type Ring-terminal connection
Protection functions Overload and short-circuit protection
Applications Commercial and industrial
Standards IEC / EN 60947-2, IEC / EN 60898
Weight approx. 0.49 kg

Frequently Asked Questions

What is the ABB S802S-D8-R used for?

The S802S-D8-R is a high-performance miniature circuit breaker designed to protect circuits against overloads and short circuits, particularly where high breaking capacity and protection of high-inrush loads are required.

What is the rated current of the ABB S802S-D8-R?

The S802S-D8-R has a rated current of 8 A.

What tripping characteristic does the ABB S802S-D8-R use?

The S802S-D8-R uses a Type D tripping characteristic, making it suitable for appropriately designed circuits supplying loads with high inrush currents, such as motors and transformers.

What is the breaking capacity of the ABB S802S-D8-R?

The S802S-D8-R has an ultimate short-circuit breaking capacity (Icu) of 50 kA.

What type of connection does the ABB S802S-D8-R use?

The S802S-D8-R is an S800S version designed with ring-terminal connections.

How many poles does the ABB S802S-D8-R have?

The ABB S802S-D8-R is a 2-pole high-performance miniature circuit breaker.

What is the ABB order code for the S802S-D8-R?

The ABB order code for the S802S-D8-R is 2CCS862002R0081.

Trusted by Electrical Professionals Worldwide

ABB S800S high-performance miniature circuit breakers provide dependable overload and short-circuit protection for demanding commercial and industrial installations, with high breaking capacity and specialised characteristics for challenging electrical loads.