Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB S802S-D16 is a 16 A two-pole Type D high-performance miniature circuit breaker with 50 kA ultimate breaking capacity at 240/415 V AC for dependable overload and short-circuit protection in demanding electrical installations.
£117.62
The ABB S802S-D16 is a high-performance 2-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits in demanding electrical installations. As part of the proven ABB S800S high-performance MCB series, it combines a high short-circuit breaking capacity with a Type D tripping characteristic for reliable protection of circuits supplying equipment with substantial starting or inrush currents.
With a rated current of 16 A and an ultimate short-circuit breaking capacity of 50 kA at 240/415 V AC, the S802S-D16 provides robust protection where high prospective fault currents must be safely interrupted. Its Type D characteristic is particularly suited to loads with high switch-on currents, helping reduce unwanted tripping during normal equipment start-up while maintaining effective overload and short-circuit protection.
The S802S-D16 is a current-limiting breaker with thermal overload and electromechanical short-circuit tripping mechanisms. Its 2-pole configuration and cage-terminal construction make it suitable for professional distribution assemblies, machinery control panels and commercial or industrial electrical systems requiring dependable high-performance circuit protection.
Miniature circuit breakers such as the ABB S802S-D16 automatically interrupt excessive current caused by overload or short-circuit conditions. The thermal tripping mechanism responds to sustained overloads, while the electromechanical mechanism provides rapid operation during short circuits to help protect conductors, equipment and electrical installations.
The Type D characteristic makes the S802S-D16 particularly suitable for applications containing equipment with high switch-on or starting currents. Combined with its current-limiting operation and 50 kA ultimate breaking capacity at 240/415 V AC, it provides robust protection for demanding commercial and industrial power distribution systems.
Tick the specs you need, then view products that match.
| Certification | UL 1077 | |
|---|---|---|
| Series | S800S | |
| ABB order code | 2CCS862001R0161 | |
| Product group | S800 / S800P / S750 MCB | |
| Product type | High-performance miniature circuit breaker (MCB) | |
| Number of poles | 2 | |
| Rated current | 16 A | |
| Tripping characteristic | Type D | |
| Ultimate short-circuit breaking capacity (Icu) at 240/415 V AC | 50 kA | |
| Ultimate short-circuit breaking capacity (Icu) at 254/440 V AC | 30 kA | |
| Ultimate short-circuit breaking capacity (Icu) at 400/690 V AC | 6 kA | |
| Rated short-circuit capacity at 230/400 V AC | 25 kA | |
| Tripping mechanisms | Thermal overload and electromechanical short-circuit | |
| Terminal type | Cage terminal | |
| Standards | IEC / EN 60947-2, IEC / EN 60898-1, UL 1077 | |
| Weight | approx. 0.49 kg |
The S802S-D16 is a high-performance miniature circuit breaker used to protect electrical circuits against overloads and short circuits, particularly where loads can produce substantial starting or inrush currents.
The S802S-D16 has a rated current of 16 A.
The breaker uses a Type D tripping characteristic, making it suitable for appropriately designed circuits supplying equipment with high starting or switch-on currents.
The S802S-D16 has an ultimate short-circuit breaking capacity of 50 kA at 240/415 V AC.
The ABB S802S-D16 is a 2-pole high-performance miniature circuit breaker.
The S802S-D16 is specified to IEC / EN 60947-2, IEC / EN 60898-1 and UL 1077.
ABB S800 high-performance miniature circuit breakers are designed for demanding electrical installations, providing dependable overload and short-circuit protection where fast arc extinction, current limiting and high breaking capacity are required.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.