ABB S801S-UCK80-R is an 80 A single-pole Type K high-performance miniature circuit breaker with 50 kA ultimate breaking capacity and ring-terminal connection for demanding direct-current circuit protection.
£122.09
The ABB S801S-UCK80-R is a high-performance single-pole miniature circuit breaker (MCB) designed for protection and control of demanding electrical circuits against overloads and short circuits. As part of the ABB S800S-UC range, this specialised version combines a Type K tripping characteristic, high short-circuit breaking capacity and ring-terminal connection for professional DC circuit protection.
With a rated current of 80 A and an ultimate short-circuit breaking capacity of 50 kA, the S801S-UCK80-R provides robust protection where high prospective fault currents may occur. Its Type K characteristic is particularly suitable for circuits such as motors, transformers and auxiliary circuits, helping prevent nuisance tripping from functional peak currents while providing sensitive thermal overload protection.
The S801S-UCK80-R is a 1-pole breaker specifically designed for direct-current applications and features a ring-terminal connection arrangement. Its combination of high breaking performance, current-limiting operation and specialised DC design makes it suitable for demanding commercial, industrial and transportation electrical systems.
High-performance circuit breakers such as the ABB S801S-UCK80-R use thermal and electromagnetic tripping principles to protect circuits against overload and short-circuit conditions. The S800S-UCK range is specifically designed for direct-current applications where high breaking capacity is required, including motor, transformer and auxiliary circuits.
The Type K characteristic helps prevent nuisance tripping when functional peak currents occur while its sensitive thermal protection helps protect cables, lines and connected equipment against damaging overcurrents. The S801S-UCK80-R can also support appropriately engineered selectivity with upstream MCCBs or back-up protection arrangements for downstream MCBs.
| Series | S800S-UC |
|---|---|
| ABB order code | 2CCS861002R1627 |
| Product group | S800 / S800P / S750 MCB |
| Product type | High-performance miniature circuit breaker (MCB) |
| Number of poles | 1 |
| Rated current | 80 A |
| Tripping characteristic | Type K |
| Ultimate short-circuit breaking capacity (Icu) | 50 kA |
| Application | Direct-current circuit protection |
| Connection type | Ring-terminal connection |
| Standard | IEC / EN 60947-2 |
| Weight | approx. 0.245 kg |
| EAN / GTIN | 7612271208691 |
The S801S-UCK80-R is a high-performance miniature circuit breaker designed to protect DC circuits such as motor, transformer and auxiliary circuits against overloads and short circuits.
The S801S-UCK80-R has a rated current of 80 A.
The breaker uses a Type K tripping characteristic, which is designed to accommodate functional peak currents while providing sensitive thermal overload protection.
The S801S-UCK80-R has an ultimate short-circuit breaking capacity of 50 kA.
Yes. The ABB S800S-UCK range is specifically designed for direct-current circuit applications requiring high breaking capacity.
The S801S-UCK80-R uses a ring-terminal connection, distinguishing this specialised version within the ABB S800S range.