ABB S801S-C20-R is a 20 A single-pole Type C high-performance miniature circuit breaker with a short-circuit breaking capacity of up to 50 kA for reliable overload and short-circuit protection.

SKU: 2CCS861002R0204Alt SKU: S801SC20RMPN: 2CCS861002R0204
Price
List Price £83.75 ex VAT
Your Price (ex VAT) Save 35%
£54.44 35% OFF
You save £29.31 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £54.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£54.44

Why Choose the ABB S801S-C20-R High Performance MCB?

The ABB S801S-C20-R is a high-performance single-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits. Part of the ABB S800S high-performance circuit breaker series, it combines effective current limitation with high breaking capacity for dependable protection in demanding commercial and industrial electrical installations.

Featuring a Type C tripping characteristic and a rated current of 20 A, the S801S-C20-R provides thermal overload protection together with rapid electromagnetic short-circuit protection. The Type C characteristic makes it suitable for appropriately designed circuits with moderate starting or inrush currents, including control equipment and inductive loads.

With a high short-circuit breaking capacity of up to 50 kA, the S801S-C20-R is suited to installations where substantial prospective fault currents may occur. Its compact single-pole construction, current-limiting performance and DIN-rail mounting make it suitable for industrial distribution boards, machinery and automation control panels.

Key Advantages

  • High-performance single-pole miniature circuit breaker for demanding electrical installations.
  • 20 A rated current with Type C tripping characteristic.
  • High short-circuit breaking capacity of up to 50 kA.
  • Type C characteristic accommodates moderate starting and inrush currents.
  • Thermal and electromagnetic tripping provides overload and short-circuit protection.
  • Current-limiting technology helps reduce fault energy and stress on downstream equipment.
  • Compact DIN-rail construction simplifies integration into distribution and control assemblies.

Key Features

  • ABB S800S high-performance MCB series.
  • 1-pole circuit breaker configuration.
  • 20 A rated current.
  • Type C tripping characteristic.
  • Short-circuit breaking capacity up to 50 kA.
  • Thermal overload protection.
  • Electromagnetic short-circuit protection.
  • High-performance current-limiting design.
  • Compact modular construction for electrical panels.
  • DIN-rail mounting for straightforward installation.

Reliable High-Performance Circuit Protection

The ABB S801S-C20-R combines thermal overload protection with rapid electromagnetic short-circuit protection. Its Type C tripping characteristic provides a practical balance between dependable fault protection and tolerance of moderate transient currents that can occur when motors, control equipment and other inductive loads are energised.

The S800S platform uses high-performance current limitation and rapid fault interruption to reduce the energy passed through during short-circuit conditions. This makes the S801S-C20-R suitable for demanding electrical distribution and industrial control applications requiring compact construction, reliable protection and high breaking performance.

Typical Applications

  • Industrial electrical distribution panels.
  • Machine and automation control panels.
  • Control and auxiliary electrical circuits.
  • Commercial electrical distribution systems.
  • Motor and inductive-load circuits where a Type C characteristic is appropriate.
  • High fault-level circuits requiring current-limiting protection.

Technical Specifications

Series S800S
ABB order code 2CCS861002R0204
Product type High-performance miniature circuit breaker (MCB)
Number of poles 1
Protected poles 1
Rated current 20 A
Tripping characteristic Type C
Short-circuit breaking capacity up to 50 kA
Rated insulation voltage (Ui) 690 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50 / 60 Hz
Mounting type DIN rail
Dimensions (H × W × D) approx. 95 × 27 × 82.5 mm
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S801S-C20-R used for?

The ABB S801S-C20-R is used to protect electrical circuits against overloads and short circuits in demanding commercial and industrial electrical installations.

What is the rated current of the S801S-C20-R?

The S801S-C20-R has a rated current of 20 A.

What tripping characteristic does this MCB use?

The S801S-C20-R uses a Type C tripping characteristic, making it suitable for appropriately designed circuits with moderate starting and inrush currents.

What is the breaking capacity of the ABB S801S-C20-R?

The S801S-C20-R is a high-performance miniature circuit breaker with a short-circuit breaking capacity of up to 50 kA.

How many poles does the S801S-C20-R have?

The S801S-C20-R is a single-pole (1P) high-performance miniature circuit breaker.

Trusted ABB Circuit Protection

ABB S800S high-performance miniature circuit breakers provide dependable overload and short-circuit protection for demanding commercial and industrial electrical systems requiring high breaking capacity, effective current limitation and robust operation.