2CCS861001R0537 ABB S801S-K32 High Performance MCB 50kA 1P Type K 32A

2CCS861001R0537 ABB S801S-K32 High Performance MCB 50kA 1P Type K 32A

ABB S801S-K32 high-performance 32 A single-pole Type K miniature circuit breaker with up to 50 kA breaking capacity for reliable overload and short-circuit protection.

SKU: 2CCS861001R0537Alt SKU: S801SK32MPN: 2CCS861001R0537
Price
List Price £92.75 ex VAT
Your Price (ex VAT) Save 35%
£60.29 35% OFF
You save £32.46 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £60.29
Trade pricing is personalised to your account

Manufacturer Lead Time

£60.29

Why Choose the ABB S801S-K32 High Performance MCB?

The ABB S801S-K32 is a high-performance single-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in demanding electrical installations. Part of the ABB S800S high-performance circuit breaker range, it combines a 32 A rated current, Type K tripping characteristic and high short-circuit breaking capability for industrial, commercial and other professional distribution applications.

The S801S-K32 is a current-limiting circuit breaker incorporating two complementary tripping mechanisms. A thermal mechanism provides overload protection, while an electromechanical mechanism provides rapid short-circuit protection. Fast arc extinction helps limit fault energy and supports dependable protection of downstream equipment and electrical infrastructure.

With a maximum ultimate breaking capacity of 50 kA at 240/415 V AC, a compact single-pole construction and interchangeable cage terminal, the S801S-K32 is particularly suitable for circuits requiring high fault-current performance. Its Type K characteristic makes it well suited to applications involving motors, transformers and other loads that can produce elevated starting currents. ABB order code 2CCS861001R0537 identifies this specific 32 A model.

Key Advantages

  • High-performance 32 A miniature circuit breaker for demanding circuit protection.
  • Type K tripping characteristic suitable for loads with higher starting or inrush currents.
  • Maximum ultimate breaking capacity of 50 kA at 240/415 V AC.
  • Thermal overload and electromechanical short-circuit tripping mechanisms.
  • Current-limiting operation helps reduce fault energy during short circuits.
  • Fast arc extinction supports reliable protection of electrical equipment.
  • Compact single-pole construction for distribution and control assemblies.
  • Suitable for residential, commercial and industrial electrical applications.

Key Features

  • ABB S800S high-performance MCB series.
  • 32 A rated current.
  • 1-pole configuration.
  • Type K tripping characteristic.
  • Ultimate short-circuit breaking capacity of 50 kA at 240/415 V AC.
  • 40 kA service breaking capacity at 240 V AC.
  • Rated operational voltage of 400 V AC according to IEC 60947-2.
  • Rated operational voltage of 125 V DC according to IEC 60947-2.
  • 690 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • 50/60 Hz rated frequency.
  • IP20 protection rating.
  • Interchangeable cage terminal with screw connection.
  • ON / OFF / TRIP contact-position indication.

Reliable High-Performance Circuit Protection

Miniature circuit breakers such as the ABB S801S-K32 automatically disconnect a circuit when excessive current results from an overload or short circuit. The thermal trip responds to sustained overload conditions, while the electromechanical trip provides rapid operation during high short-circuit currents, helping protect conductors and connected electrical equipment.

The S800S range is engineered for applications requiring high fault-breaking performance in a compact format. The Type K characteristic makes the S801S-K32 particularly useful for circuits with elevated starting currents, while its current-limiting design and rapid arc extinction help minimise the electrical and thermal stresses associated with short-circuit faults.

Typical Applications

  • Industrial electrical distribution systems.
  • Motor and machinery circuits.
  • Industrial control panels and switchgear.
  • Automation and production equipment.
  • Transformer and inductive-load circuits.
  • Circuits with elevated starting or inrush currents.
  • Commercial electrical distribution systems.
  • High fault-level electrical installations.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 1077
Series S800S
ABB order code 2CCS861001R0537
Product type High-performance miniature circuit breaker (MCB)
Number of poles 1
Number of protected poles 1
Rated current 32 A
Tripping characteristic Type K
Ultimate breaking capacity (Icu) 50 kA at 240 V AC
Service breaking capacity (Ics) 40 kA at 240 V AC
Ultimate breaking capacity at 125 V DC 30 kA
Rated operational voltage 400 V AC according to IEC 60947-2
Rated DC operational voltage 125 V DC according to IEC 60947-2
Rated voltage according to IEC 60898-1 230/400 V AC
Rated insulation voltage (Ui) 690 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated frequency 50/60 Hz
Protection rating IP20
Pollution degree 3
Terminal type Interchangeable cage / screw terminal
Tightening torque 3.5 N·m
Power loss 3.7 W per pole at rated operating conditions
Operating temperature −25 to +60 °C
Dimensions (H × W × D) 95 × 27 × 82.5 mm
Weight approx. 0.245 kg
Standards IEC/EN 60947-2, IEC/EN 60898-1, UL 1077

Frequently Asked Questions

What is the ABB S801S-K32 used for?

The ABB S801S-K32 is a high-performance miniature circuit breaker used to protect electrical circuits against overloads and short circuits in industrial, commercial and other demanding electrical installations.

What is the current rating of the S801S-K32?

The S801S-K32 has a rated current of 32 A and uses a Type K tripping characteristic.

What is the breaking capacity of the ABB S801S-K32?

The S801S-K32 has an ultimate short-circuit breaking capacity of 50 kA at 240 V AC, with ABB also specifying the S800S-K range as a 50 kA class at 240/415 V AC.

What does the Type K characteristic mean?

The Type K characteristic is suitable for circuits containing loads with relatively high starting or inrush currents, such as motors and transformers, helping avoid unwanted tripping while maintaining overload and short-circuit protection.

Which standards does the ABB S801S-K32 comply with?

The S801S-K32 complies with IEC/EN 60947-2, IEC/EN 60898-1 and UL 1077.