ABB S801S-K6 is a 1-pole 6 A Type K high-performance miniature circuit breaker with 50 kA short-circuit breaking capacity for demanding industrial electrical circuits.

SKU: 2CCS861001R0067Alt SKU: S801SK6MPN: 2CCS861001R0067
Price
List Price £111.11 ex VAT
Your Price (ex VAT) Save 35%
£72.22 35% OFF
You save £38.89 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £72.22
Trade pricing is personalised to your account

Manufacturer Lead Time

£72.22

Why Choose the ABB S801S-K6 MCB?

The ABB S801S-K6 is a high-performance 1-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in demanding industrial electrical systems. As part of the ABB S800S high-performance circuit breaker range, it combines a rated current of 6 A, Type K tripping characteristic and a high 50 kA short-circuit breaking capacity.

The S800S platform is engineered for applications requiring greater short-circuit performance than conventional miniature circuit breakers. Its compact modular construction makes the S801S-K6 suitable for industrial switchboards, machinery control panels and distribution systems where dependable protection and efficient use of panel space are important.

With its Type K characteristic, the S801S-K6 is particularly suited to circuits supplying equipment with elevated starting or inrush currents, including motors, transformers and other inductive loads. The combination of a 6 A rating and 50 kA breaking capacity provides robust protection for demanding single-pole circuits.

Key Advantages

  • High-performance 1-pole miniature circuit breaker.
  • 6 A rated current for lower-current power and control circuits.
  • High 50 kA short-circuit breaking capacity.
  • Type K tripping characteristic suitable for loads with elevated starting currents.
  • Combined thermal and magnetic protection against overloads and short circuits.
  • Compact modular design for industrial distribution and control equipment.

Key Features

  • ABB S800S high-performance MCB series.
  • 1-pole configuration.
  • 6 A rated current.
  • Type K tripping characteristic.
  • 50 kA breaking capacity.
  • Thermal overload and electromagnetic short-circuit protection.
  • Suitable for circuits supplying motors, transformers and other inductive loads.
  • Designed for demanding industrial electrical distribution applications.

High-Performance Protection for Inductive Loads

Miniature circuit breakers automatically disconnect electrical circuits when overload or short-circuit conditions occur. Thermal operation provides protection against sustained overload currents, while electromagnetic operation enables rapid interruption of high fault currents to help protect conductors and connected equipment.

The Type K characteristic of the S801S-K6 provides tolerance for the elevated starting currents associated with motors, transformers and other inductive loads while maintaining effective overcurrent protection. Combined with the high breaking capacity of the ABB S800S platform, this makes the breaker suitable for demanding industrial control and distribution systems.

Typical Applications

  • Industrial electrical distribution systems.
  • Motor and machinery circuits.
  • Transformer and inductive-load circuits.
  • Industrial control panels and switchboards.
  • Automation and production equipment.
  • Installations requiring high short-circuit breaking capacity.

Technical Specifications

Series S800S
ABB order code 2CCS861001R0067
Product type Miniature circuit breaker (MCB)
Number of poles 1
Rated current 6 A
Tripping characteristic Type K
Short-circuit breaking capacity 50 kA
Protection function Overload and short-circuit protection
Application Industrial electrical distribution and equipment protection

Frequently Asked Questions

What is the ABB S801S-K6 used for?

The S801S-K6 provides overload and short-circuit protection for demanding single-pole electrical circuits, including circuits supplying motors, transformers and other inductive loads.

What is the rated current of the S801S-K6?

The circuit breaker has a rated current of 6 A.

What tripping characteristic does the S801S-K6 use?

The S801S-K6 uses a Type K tripping characteristic, making it suitable for loads that can draw elevated current during starting.

What is the breaking capacity of the ABB S801S-K6?

The S801S-K6 has a short-circuit breaking capacity of 50 kA, providing high fault-current performance for demanding electrical installations.

How many poles does the S801S-K6 have?

The S801S-K6 is a 1-pole MCB designed for single-pole circuit protection.

Trusted High-Performance Circuit Protection from ABB

ABB S800S high-performance miniature circuit breakers provide robust overload and short-circuit protection for demanding industrial electrical systems where high breaking capacity, compact construction and dependable operation are essential.