2CCS573001R0204 ABB S403M-C20 20 A 3-Pole Type C Miniature Circuit Breaker

2CCS573001R0204 ABB S403M-C20 20 A 3-Pole Type C Miniature Circuit Breaker

ABB S403M-C20 is a 20 A 3-pole Type C miniature circuit breaker for the SMISSLINE TP plug-in system, providing reliable overload and short-circuit protection with a 10 kA Icn breaking capacity.

SKU: 2CCS573001R0204Alt SKU: S403MC20MPN: 2CCS573001R0204
Price
List Price £131.02 ex VAT
Your Price (ex VAT) Save 35%
£85.16 35% OFF
You save £45.86 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £85.16
Trade pricing is personalised to your account

Manufacturer Lead Time

£85.16

Why Choose the ABB S403M-C20 Miniature Circuit Breaker?

The ABB S403M-C20 is a high-performance 3-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in three-phase electrical circuits. As part of the ABB S400M / SMISSLINE TP plug-in system, it combines current-limiting circuit protection with convenient plug-in installation for compatible commercial, industrial and critical-power distribution assemblies.

This circuit breaker has a rated current of 20 A and a Type C tripping characteristic, making it suitable for general-purpose circuits and equipment where moderate starting or inrush currents can occur. Its delayed thermal tripping mechanism provides overload protection, while an electromechanical tripping mechanism provides rapid protection against short-circuit faults.

With a rated short-circuit breaking capacity Icn of 10 kA at 230/400 V AC and a rated operational voltage of up to 415 V AC, the S403M-C20 provides dependable protection for professional three-phase electrical installations. Its compact 54 × 91 × 82 mm construction, IP20 protection and SMISSLINE TP plug-in format support efficient panel installation, replacement and maintenance.

Key Advantages

  • Reliable 3-pole miniature circuit breaker for three-phase circuit protection.
  • 20 A rated current for control, machinery and general distribution circuits.
  • Type C tripping characteristic accommodates moderate starting and inrush currents.
  • 10 kA rated short-circuit breaking capacity Icn at 230/400 V AC.
  • 15 kA rated ultimate short-circuit breaking capacity Icu at 230/400 V AC.
  • Three protected poles provide coordinated three-phase overcurrent protection.
  • Designed specifically for the ABB SMISSLINE TP plug-in system.
  • Plug-in construction supports efficient installation, replacement and maintenance.

Key Features

  • ABB S400M / SMISSLINE TP series.
  • 20 A rated current.
  • 3-pole configuration with three protected poles.
  • Type C tripping characteristic.
  • 415 V AC rated operational voltage.
  • 10 kA Icn to IEC/EN 60898-1 at 230/400 V AC.
  • 15 kA Icu to IEC/EN 60947-2 at 230/400 V AC.
  • 440 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • 50–60 Hz operating frequency.
  • IP20 degree of protection.
  • Plug-in SMISSLINE TP mounting for compatible modular distribution systems.

Reliable Three-Phase Circuit Protection

The ABB S403M-C20 uses complementary thermal and electromechanical tripping mechanisms to protect connected cables, conductors and equipment. The delayed thermal release responds to sustained overload conditions, while the electromechanical release provides rapid disconnection during short-circuit faults, helping limit damaging thermal and electrical stresses within the installation.

Its Type C characteristic provides a practical balance between fault sensitivity and tolerance of moderate starting currents, making the S403M-C20 suitable for a broad range of commercial and industrial circuits. Combined with ABB's SMISSLINE TP plug-in architecture, it provides dependable three-phase protection while supporting efficient installation and straightforward device replacement.

Typical Applications

  • Three-phase commercial distribution circuits.
  • Industrial control and auxiliary circuits.
  • Machine control panels and automation systems.
  • General-purpose three-phase electrical loads.
  • Industrial production and processing machinery.
  • Building-services electrical distribution.
  • Critical-power distribution installations.
  • OEM machinery and electrical control equipment.
  • ABB SMISSLINE TP modular distribution assemblies.

Technical Specifications

Product group SMISSLINE Plug-in System
Range SMISSLINE TP
Series S400M
ABB order code 2CCS573001R0204
EAN 7612270102976
Product type Miniature circuit breaker (MCB)
Rated current 20 A
Number of poles 3
Number of protected poles 3
Tripping characteristic Type C
Rated operational voltage 415 V AC
Rated insulation voltage 440 V
Rated impulse withstand voltage 4 kV
Rated short-circuit breaking capacity Icn 10 kA at 230/400 V AC
Rated ultimate short-circuit breaking capacity Icu 15 kA at 230/400 V AC
Frequency 50–60 Hz
Protection rating IP20
Energy limiting class 3
Overvoltage category 3
Pollution degree 3
Tripping mechanism Delayed thermal and electromechanical
Mounting type Plug-in SMISSLINE TP
Module width 3 modules
Maximum conductor cross-section 35 mm²
Operating ambient temperature -25 to +55 °C
Width 54 mm
Height 91 mm
Depth 82 mm
Dimensions (W × H × D) 54 × 91 × 82 mm
Weight approx. 322 g
Standards IEC/EN 60898-1 and IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S403M-C20 used for?

The ABB S403M-C20 is a 3-pole miniature circuit breaker designed to protect three-phase electrical circuits against overload and short-circuit currents in commercial, industrial, control and automation applications.

What is the current rating of the S403M-C20?

The S403M-C20 has a rated current of 20 A and provides overcurrent protection across three protected poles.

What does the Type C tripping characteristic mean?

The Type C tripping characteristic provides overload and short-circuit protection while accommodating moderate short-duration starting or inrush currents that can occur during normal operation of suitable electrical equipment.

What is the breaking capacity of the ABB S403M-C20?

The S403M-C20 has a rated short-circuit breaking capacity Icn of 10 kA at 230/400 V AC to IEC/EN 60898-1 and a rated ultimate short-circuit breaking capacity Icu of 15 kA at 230/400 V AC to IEC/EN 60947-2.

How is the ABB S403M-C20 installed?

The S403M-C20 is designed for plug-in installation within compatible ABB SMISSLINE TP distribution systems, providing direct contact with the socket system and helping simplify installation, replacement and maintenance.

Trusted ABB Circuit Protection

ABB SMISSLINE TP S400M miniature circuit breakers combine dependable overload and short-circuit protection with a flexible plug-in distribution platform, providing an efficient protection solution for commercial, industrial and critical-power electrical systems.