2CCS573001R0157 ABB S403M-K0.5 Miniature Circuit Breaker 0.5 A 3P Type K 10 kA

2CCS573001R0157 ABB S403M-K0.5 Miniature Circuit Breaker 0.5 A 3P Type K 10 kA

ABB S403M-K0.5 is a 0.5 A 3-pole Type K miniature circuit breaker with 10 kA breaking capacity, designed for overload and short-circuit protection in SMISSLINE TP plug-in distribution systems.

SKU: 2CCS573001R0157Alt SKU: S403MK0.5MPN: 2CCS573001R0157
Price
List Price £152.88 ex VAT
Your Price (ex VAT) Save 35%
£99.37 35% OFF
You save £53.51 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £99.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£99.37

Why Choose the ABB S403M-K0.5 Miniature Circuit Breaker?

The ABB S403M-K0.5 is a high-performance 3-pole miniature circuit breaker (MCB) designed for reliable overload and short-circuit protection in low-current three-phase electrical circuits. As part of the ABB S400M / SMISSLINE TP series, it combines a 0.5 A rated current, Type K tripping characteristic and 10 kA breaking capacity with ABB's convenient plug-in distribution technology.

The Type K characteristic makes the S403M-K0.5 particularly suitable for correctly coordinated circuits containing inductive loads and equipment that can produce elevated starting currents. Its three protected poles provide coordinated protection across three-phase circuits, while the low 0.5 A current rating makes it well suited to sensitive control, instrumentation and auxiliary circuits.

With a 0.5 A rated current, 3-pole configuration and rated AC voltage of 415 V AC, the S403M-K0.5 provides dependable protection in compact distribution assemblies. Its 54 mm width and SMISSLINE TP plug-in construction support efficient installation and straightforward integration into compatible ABB distribution systems.

Key Advantages

  • Reliable 3-pole miniature circuit breaker for overload and short-circuit protection.
  • Low 0.5 A rated current for sensitive control and auxiliary circuits.
  • Type K tripping characteristic suitable for appropriately coordinated loads with elevated starting currents.
  • 10 kA short-circuit breaking capacity.
  • Ultimate short-circuit breaking capacity of 25 kA at 415 V AC.
  • Three protected poles for coordinated three-phase circuit protection.
  • Plug-in construction designed for the ABB SMISSLINE TP system.

Key Features

  • ABB S400M / SMISSLINE TP series.
  • 0.5 A rated current.
  • 3 protected poles.
  • Type K tripping characteristic.
  • 415 V AC rated voltage.
  • 10 kA breaking capacity.
  • 25 kA ultimate short-circuit breaking capacity at 415 V AC.
  • IP20 degree of protection.
  • Electrical endurance of 10,000 cycles.
  • Compact three-module SMISSLINE TP plug-in construction.

Reliable Protection for Low-Current Three-Phase Circuits

Miniature circuit breakers such as the ABB S403M-K0.5 protect electrical conductors and connected equipment by interrupting current when overload or short-circuit conditions occur. The Type K characteristic is designed for applications where correctly coordinated equipment can produce higher starting currents while still requiring dependable overload and short-circuit protection.

The S403M-K0.5 combines this specialised tripping characteristic with ABB's SMISSLINE TP plug-in architecture. Its three-pole construction, 0.5 A rating and 10 kA breaking capacity make it a practical solution for sensitive three-phase control and auxiliary circuits requiring reliable protection and modular system integration.

Typical Applications

  • Low-current three-phase control circuits.
  • Industrial automation and machine control systems.
  • Instrumentation and auxiliary circuits.
  • Control transformer circuits with appropriate coordination.
  • Industrial electrical distribution boards.
  • Inductive loads with correctly assessed starting-current requirements.
  • ABB SMISSLINE TP modular distribution assemblies.

Technical Specifications

Series S400M / SMISSLINE TP
ABB order code 2CCS573001R0157
EAN 7612270103140
Product type Miniature circuit breaker (MCB)
Rated current 0.5 A
Number of poles 3
Number of protected poles 3
Tripping characteristic Type K
Rated AC voltage 415 V AC
Short-circuit breaking capacity 10 kA
Ultimate short-circuit breaking capacity (Icu) 25 kA at 415 V AC
Protection rating IP20
Operating temperature -25 to +55 °C
Electrical endurance 10,000 cycles
Conductor connection range 0.75–35 mm²
Mounting type SMISSLINE TP plug-in system
Width 54 mm
Height 91 mm
Depth 75 mm
Width in modules 3
Weight approx. 322 g
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S403M-K0.5 used for?

The S403M-K0.5 is a 3-pole miniature circuit breaker designed to protect compatible low-current three-phase electrical circuits against overloads and short circuits.

What is the current rating of the S403M-K0.5?

The ABB S403M-K0.5 has a rated current of 0.5 A, equivalent to 500 mA.

What tripping characteristic does the S403M-K0.5 use?

The S403M-K0.5 uses a Type K tripping characteristic, making it suitable for correctly coordinated circuits containing loads that can produce elevated starting currents.

What is the breaking capacity of the ABB S403M-K0.5?

The S403M-K0.5 has a 10 kA short-circuit breaking capacity and an ultimate short-circuit breaking capacity of 25 kA at 415 V AC.

How is the ABB S403M-K0.5 installed?

The breaker is designed for plug-in installation within the ABB SMISSLINE TP system, enabling efficient integration into compatible modular electrical distribution assemblies.

Trusted ABB Three-Phase Circuit Protection

ABB S400M miniature circuit breakers provide dependable overload and short-circuit protection for commercial and industrial applications while combining specialised tripping characteristics with the modular advantages of the SMISSLINE TP plug-in distribution system.