2CCS573001R0024 ABB S403M-C2 MCB 10kA 3P Type C 2A

2CCS573001R0024 ABB S403M-C2 MCB 10kA 3P Type C 2A

ABB S403M-C2 is a 2 A Type C 3-pole miniature circuit breaker with 10 kA rated short-circuit breaking capacity, designed for reliable overload and short-circuit protection in SMISSLINE TP plug-in electrical distribution systems.

SKU: 2CCS573001R0024Alt SKU: S403MC2MPN: 2CCS573001R0024
Price
List Price £170.51 ex VAT
Your Price (ex VAT) Save 35%
£110.83 35% OFF
You save £59.68 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £110.83
Trade pricing is personalised to your account

Manufacturer Lead Time

£110.83

Why Choose the ABB S403M-C2 Miniature Circuit Breaker?

The ABB S403M-C2 is a 3-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in three-phase electrical distribution systems. Part of the ABB S400M range for the SMISSLINE TP plug-in system, it combines a 2 A rated current, Type C tripping characteristic and 10 kA rated short-circuit breaking capacity.

The S403M-C2 is a current-limiting circuit breaker incorporating a delayed thermal tripping mechanism for overload protection and an electromagnetic tripping mechanism for short-circuit protection. Its Type C characteristic accommodates moderate starting and inrush currents, making it suitable for appropriately designed industrial, commercial, control and auxiliary circuits.

With 3 protected poles, a 230/400 V AC rated operational voltage and 25 kA ultimate short-circuit breaking capacity to IEC/EN 60947-2 at 230/400 V AC, the S403M-C2 provides robust three-phase circuit protection. Its SMISSLINE TP plug-in format enables efficient integration into compatible ABB modular distribution assemblies.

Key Advantages

  • 2 A rated current for precise protection of appropriately rated low-current three-phase circuits.
  • 3 protected poles for coordinated three-phase circuit protection.
  • Type C tripping characteristic suited to circuits with moderate starting or inrush currents.
  • 10 kA Icn rated short-circuit breaking capacity to IEC/EN 60898-1.
  • 25 kA Icu ultimate short-circuit breaking capacity at 230/400 V AC to IEC/EN 60947-2.
  • Purpose-designed for the ABB SMISSLINE TP plug-in system.

Key Features

  • ABB S400M series miniature circuit breaker.
  • 2 A nominal current rating.
  • Type C tripping characteristic.
  • 3-pole / 3 protected-pole configuration.
  • 230/400 V AC rated operational voltage.
  • 50–60 Hz rated frequency.
  • 10 kA Icn short-circuit breaking capacity.
  • 25 kA Icu ultimate short-circuit breaking capacity at 230/400 V AC.
  • 4 kV rated impulse withstand voltage.
  • Energy limiting class 3.
  • IP20 degree of protection.
  • SMISSLINE TP plug-in mounting for compatible distribution systems.

Reliable Three-Phase Circuit Protection

The ABB S403M-C2 protects electrical circuits against excessive current caused by overloads and short circuits. Its delayed thermal release responds to sustained overload conditions, while the electromagnetic release rapidly interrupts short-circuit currents, helping protect conductors and connected equipment.

The combination of a 2 A Type C characteristic, 3 protected poles and 10 kA Icn breaking capacity makes the S403M-C2 well suited to appropriately designed low-current three-phase circuits. Its SMISSLINE TP plug-in construction also supports efficient integration into modular commercial, industrial and critical-power distribution systems.

Typical Applications

  • ABB SMISSLINE TP three-phase distribution systems.
  • Industrial control and auxiliary circuits.
  • Automation and machine-control panels.
  • Commercial and industrial switchboards.
  • Low-current three-phase equipment circuits.
  • Circuits requiring 2 A Type C overcurrent protection.

Technical Specifications

Series S400M / SMISSLINE TP
ABB order code 2CCS573001R0024
EAN 7612270102891
Product type Miniature circuit breaker (MCB)
Number of poles 3
Number of protected poles 3
Rated current 2 A
Tripping characteristic Type C
Rated operational voltage 230/400 V AC
Frequency 50–60 Hz
Rated short-circuit breaking capacity (Icn) 10 kA
Ultimate short-circuit breaking capacity (Icu) at 230 V AC 25 kA
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 25 kA
Rated insulation voltage (Ui) 440 V
Rated impulse withstand voltage (Uimp) 4 kV
Energy limiting class 3
Power loss 5.4 W
Protection rating IP20
Electrical endurance 10,000 cycles
Conductor connection range 0.75–35 mm²
Mounting type SMISSLINE TP plug-in
Width 3 modules / 54 mm
Height 91 mm
Installation depth 75 mm
Net weight approx. 401 g
Operating temperature −25 to +60 °C
Standards IEC/EN 60898-1, IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S403M-C2 used for?

The ABB S403M-C2 is a 3-pole miniature circuit breaker designed to provide overload and short-circuit protection for appropriately rated three-phase circuits in compatible ABB SMISSLINE TP systems.

What is the current rating of the S403M-C2?

The S403M-C2 has a rated current of 2 A across its three protected poles.

What does the Type C characteristic mean?

The Type C tripping characteristic accommodates moderate starting and inrush currents, making it suitable for appropriately designed commercial, industrial, automation and control circuits.

What is the breaking capacity of the ABB S403M-C2?

The S403M-C2 has a rated short-circuit breaking capacity of 10 kA to IEC/EN 60898-1 and an ultimate short-circuit breaking capacity of 25 kA at 230/400 V AC to IEC/EN 60947-2.

How is the ABB S403M-C2 installed?

The S403M-C2 is designed for plug-in installation in compatible ABB SMISSLINE TP systems. Its three-pole construction occupies three modular spaces with a width of 54 mm.

Trusted ABB Three-Phase Circuit Protection

ABB S400M miniature circuit breakers combine current-limiting protection, robust short-circuit performance and SMISSLINE TP plug-in technology for dependable commercial, industrial and critical-power electrical distribution.