2CCS572001R1638 ABB S402M-UCZ63 63 A 2-Pole Type Z DC Miniature Circuit Breaker

2CCS572001R1638 ABB S402M-UCZ63 63 A 2-Pole Type Z DC Miniature Circuit Breaker

ABB S402M-UCZ63 is a 63 A 2-pole UC-Z Type Z miniature circuit breaker for the SMISSLINE TP plug-in system, providing sensitive overload and short-circuit protection for DC circuits rated up to 440 V.

SKU: 2CCS572001R1638Alt SKU: S402MUCZ63MPN: 2CCS572001R1638
Price
List Price £295.83 ex VAT
Your Price (ex VAT) Save 35%
£192.29 35% OFF
You save £103.54 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £192.29
Trade pricing is personalised to your account

Manufacturer Lead Time

£192.29

Why Choose the ABB S402M-UCZ63 DC Miniature Circuit Breaker?

The ABB S402M-UCZ63 is a high-performance 2-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in direct-current electrical systems. Part of the ABB S400M-UC / SMISSLINE TP plug-in system, it combines dedicated DC circuit protection with ABB's modular plug-in architecture for efficient installation in compatible industrial and commercial distribution assemblies.

This circuit breaker has a rated current of 63 A and a UC-Z / Type Z tripping characteristic. The sensitive Type Z characteristic is suited to appropriate electronic, control and instrumentation circuits where rapid magnetic tripping is required to protect connected equipment against excessive fault currents.

The S402M-UCZ63 is rated for operation up to 440 V DC and provides a breaking capacity of up to 25 kA. Its compact 36 × 91 × 75 mm enclosure, IP20 protection and SMISSLINE TP plug-in construction make it a practical circuit-protection solution for demanding DC control, automation and distribution systems.

Key Advantages

  • Specialised 2-pole miniature circuit breaker for DC applications.
  • 63 A rated current for higher-current DC circuits.
  • UC-Z / Type Z tripping characteristic for sensitive circuit protection.
  • Rated for operation up to 440 V DC.
  • Breaking capacity of up to 25 kA.
  • Designed for the ABB SMISSLINE TP plug-in system.
  • Two-pole construction provides coordinated overcurrent protection.
  • Compact 2-module format helps optimise distribution-board space.

Key Features

  • ABB S400M-UC / SMISSLINE TP series.
  • 63 A rated current.
  • 2-pole configuration.
  • UC-Z / Type Z tripping characteristic.
  • 440 V DC rated voltage.
  • Breaking capacity of up to 25 kA.
  • IP20 degree of protection.
  • Plug-in SMISSLINE TP mounting for modular distribution systems.
  • Connection capacity up to 35 mm².
  • Electrical endurance of up to 10,000 operating cycles.
  • Operating temperature range from -25 to +55 °C.
  • Compliant with IEC/EN 60947-2.

Sensitive Protection for DC Electrical Systems

DC miniature circuit breakers such as the ABB S402M-UCZ63 automatically disconnect a circuit when excessive current occurs because of an overload or short circuit. Dedicated DC switching capability is important because direct-current arcs do not naturally pass through the regular zero-current points found in AC waveforms, requiring suitably designed protective devices for dependable fault interruption.

The Type Z characteristic provides sensitive magnetic tripping and is particularly useful for appropriate electronic, control and instrumentation circuits. Combined with ABB's SMISSLINE TP plug-in architecture, the S402M-UCZ63 provides high-current DC circuit protection while supporting efficient installation, replacement and maintenance within compatible modular distribution systems.

Typical Applications

  • Industrial DC distribution systems.
  • DC control and auxiliary circuits.
  • Sensitive electronic equipment circuits.
  • Industrial instrumentation and monitoring systems.
  • Machine control panels and automation equipment.
  • Battery-backed power and distribution circuits.
  • DC power-supply output circuits.
  • OEM machinery incorporating DC electrical systems.
  • ABB SMISSLINE TP modular distribution assemblies.

Technical Specifications

Product group SMISSLINE Plug-in System
Range SMISSLINE TP
Series S400M-UC
ABB order code 2CCS572001R1638
EAN 7612270110414
Product type DC miniature circuit breaker (MCB)
Rated current 63 A
Number of poles 2
Tripping characteristic UC-Z / Type Z
Rated DC voltage 440 V DC
Rated AC voltage 440 V AC
Breaking capacity up to 25 kA
Protection rating IP20
Mounting type Plug-in SMISSLINE TP
Module width 2 modules
Connection conductor cross-section up to 35 mm²
Electrical endurance 10,000 cycles
Operating ambient temperature -25 to +55 °C
Width 36 mm
Height 91 mm
Depth 75 mm
Dimensions (W × H × D) 36 × 91 × 75 mm
Weight approx. 221 g
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S402M-UCZ63 used for?

The ABB S402M-UCZ63 is a 2-pole miniature circuit breaker designed to protect DC electrical circuits against overload and short-circuit currents in industrial control, automation, instrumentation and distribution applications.

What is the current rating of the S402M-UCZ63?

The S402M-UCZ63 has a rated current of 63 A, making it suitable for higher-current circuits requiring the sensitive UC-Z tripping characteristic.

What does the Type Z tripping characteristic mean?

The UC-Z / Type Z characteristic provides sensitive magnetic tripping and is suited to appropriate circuits where electronic, control or instrumentation equipment requires rapid protection against excessive fault currents.

What voltage is the ABB S402M-UCZ63 rated for?

The S402M-UCZ63 is rated for up to 440 V DC and 440 V AC, subject to the applicable ABB installation and connection requirements.

What is the breaking capacity of the ABB S402M-UCZ63?

The S402M-UCZ63 provides a breaking capacity of up to 25 kA, with the applicable short-circuit rating dependent on the operating voltage and installation arrangement.

Trusted ABB DC Circuit Protection