2CCS572001R1404 ABB S402M-UCC40 40 A 2-Pole Type C DC Miniature Circuit Breaker

2CCS572001R1404 ABB S402M-UCC40 40 A 2-Pole Type C DC Miniature Circuit Breaker

ABB S402M-UCC40 is a 40 A 2-pole UC-C Type C miniature circuit breaker for the SMISSLINE TP plug-in system, providing reliable overload and short-circuit protection for DC circuits up to 440 V.

SKU: 2CCS572001R1404Alt SKU: S402MUCC40MPN: 2CCS572001R1404
Price
List Price £191.35 ex VAT
Your Price (ex VAT) Save 35%
£124.38 35% OFF
You save £66.97 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £124.38
Trade pricing is personalised to your account

Manufacturer Lead Time

£124.38

Why Choose the ABB S402M-UCC40 DC Miniature Circuit Breaker?

The ABB S402M-UCC40 is a high-performance 2-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in direct-current and alternating-current electrical systems. As part of the ABB S400M-UC / SMISSLINE TP plug-in system, it combines versatile circuit protection with convenient plug-in installation for compatible commercial and industrial distribution assemblies.

This circuit breaker has a rated current of 40 A and a UC-C / Type C tripping characteristic, making it suitable for circuits where moderate transient or inrush currents can occur during normal operation. Its two-pole construction supports coordinated protection and enables operation in higher-voltage DC circuits when connected according to ABB's specified arrangement.

The S402M-UCC40 supports two-pole operation up to 440 V DC and provides a short-circuit breaking capacity of 10 kA at 440 V DC. Its compact 36 × 91 × 75 mm construction, IP20 protection and SMISSLINE TP plug-in mounting make it a practical protection solution for professional DC power, automation and control systems.

Key Advantages

  • Versatile 2-pole miniature circuit breaker for DC and AC applications.
  • 40 A rated current for control, auxiliary and power-distribution circuits.
  • UC-C / Type C tripping characteristic accommodates moderate transient and inrush currents.
  • Supports two-pole operation up to 440 V DC.
  • 10 kA short-circuit breaking capacity at 440 V DC.
  • Designed for the ABB SMISSLINE TP plug-in system.
  • Two-pole construction provides coordinated overcurrent protection.
  • Compact 2-module design helps optimise distribution-board space.

Key Features

  • ABB S400M-UC / SMISSLINE TP series.
  • 40 A rated current.
  • 2-pole configuration.
  • UC-C / Type C tripping characteristic.
  • 440 V DC maximum two-pole operating voltage.
  • 10 kA short-circuit breaking capacity at 440 V DC.
  • 10 kA breaking capacity at 230/400 V AC.
  • IP20 degree of protection.
  • Plug-in SMISSLINE TP mounting for modular distribution systems.
  • Connection capacity from 0.75–35 mm².
  • Electrical endurance of up to 10,000 operating cycles.
  • Compliant with IEC/EN 60947-2.

Reliable Protection for DC Electrical Systems

DC miniature circuit breakers such as the ABB S402M-UCC40 automatically disconnect a circuit when excessive current occurs because of an overload or short circuit. Dedicated DC switching capability is important because direct-current arcs do not naturally pass through the regular zero-current points found in AC waveforms, requiring appropriately designed protective devices and connection arrangements for dependable fault interruption.

For higher-voltage DC applications, the two poles of the S402M-UCC40 can be connected according to ABB's specified arrangement to support operation up to 440 V DC. Combined with the SMISSLINE TP plug-in platform, the breaker provides effective circuit protection while supporting efficient installation, replacement and maintenance in compatible modular distribution systems.

Typical Applications

  • Industrial DC distribution systems.
  • DC control and auxiliary circuits.
  • Machine control panels and automation systems.
  • Battery-backed power and distribution circuits.
  • DC power-supply output circuits.
  • Industrial instrumentation and monitoring equipment.
  • Commercial and industrial AC/DC distribution.
  • OEM machinery incorporating DC electrical systems.
  • ABB SMISSLINE TP modular distribution assemblies.

Technical Specifications

Product group SMISSLINE Plug-in System
Range SMISSLINE TP
Series S400M-UC
ABB order code 2CCS572001R1404
Product type Miniature circuit breaker (MCB) for AC/DC applications
Rated current 40 A
Number of poles 2
Tripping characteristic UC-C / Type C
Maximum two-pole DC operating voltage 440 V DC
Short-circuit breaking capacity at 440 V DC 10 kA
AC breaking capacity 10 kA at 230/400 V AC
Protection rating IP20
Mounting type Plug-in SMISSLINE TP
Module width 2 modules
Connection conductor cross-section 0.75–35 mm²
Electrical endurance 10,000 cycles
Operating ambient temperature -25 to +60 °C
Width 36 mm
Height 91 mm
Depth 75 mm
Dimensions (W × H × D) 36 × 91 × 75 mm
Weight approx. 0.221 kg
Pack quantity 5 pieces
EAN 7612270110056
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S402M-UCC40 used for?

The ABB S402M-UCC40 is a 2-pole miniature circuit breaker designed to protect DC and AC electrical circuits against overload and short-circuit currents in commercial and industrial control, automation and distribution applications.

What is the current rating of the S402M-UCC40?

The S402M-UCC40 has a rated current of 40 A.

What does the UC-C / Type C characteristic mean?

The UC-C / Type C tripping characteristic provides overload and short-circuit protection while accommodating moderate short-duration transient or inrush currents that can occur during normal operation of suitable electrical loads.

What DC voltage can the ABB S402M-UCC40 handle?

The two-pole S402M-UCC40 supports operation up to 440 V DC when its poles are connected in accordance with ABB's specified two-pole DC connection arrangement.

What is the breaking capacity of the ABB S402M-UCC40?

The S402M-UCC40 provides a short-circuit breaking capacity of 10 kA at 440 V DC and 10 kA at 230/400 V AC.

Trusted ABB DC Circuit Protection

ABB S400M-UC miniature circuit breakers provide dependable protection for DC and AC electrical systems, combining effective overcurrent protection with the installation flexibility and modular convenience of the SMISSLINE TP plug-in distribution platform.