2CCS572001R1324 ABB S402M-UCC32 DC Miniature Circuit Breaker 32 A 2P Type C

2CCS572001R1324 ABB S402M-UCC32 DC Miniature Circuit Breaker 32 A 2P Type C

ABB S402M-UCC32 is a 32 A 2-pole Type C miniature circuit breaker for DC applications up to 440 V DC, designed for overload and short-circuit protection in SMISSLINE TP plug-in distribution systems.

SKU: 2CCS572001R1324Alt SKU: S402MUCC32MPN: 2CCS572001R1324
Price
List Price £171.85 ex VAT
Your Price (ex VAT) Save 35%
£111.70 35% OFF
You save £60.15 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £111.70
Trade pricing is personalised to your account

Manufacturer Lead Time

£111.70

Why Choose the ABB S402M-UCC32 DC Miniature Circuit Breaker?

The ABB S402M-UCC32 is a high-performance 2-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in DC electrical distribution systems. As part of the ABB S400M UC / SMISSLINE TP series, it combines a 32 A rated current, Type C tripping characteristic and convenient plug-in installation.

Designed for industrial and commercial circuit protection, the S402M-UCC32 uses a Type C / UC-C characteristic suitable for general-purpose loads and circuits where moderate starting or inrush currents may occur. Its two-pole construction and SMISSLINE TP plug-in design support efficient integration into compatible modular distribution assemblies.

With a 32 A rated current, 2-pole configuration and support for two-pole applications up to 440 V DC, the S402M-UCC32 is well suited to control, automation and DC power distribution circuits. Its compact two-module format provides dependable protection while making efficient use of space in SMISSLINE TP installations.

Key Advantages

  • Reliable 2-pole miniature circuit breaker for overload and short-circuit protection.
  • 32 A rated current for industrial control and distribution circuits.
  • Type C / UC-C tripping characteristic suitable for loads with moderate inrush currents.
  • Designed for DC circuit protection and flexible AC/DC applications.
  • Two-pole operation supports applications up to 440 V DC.
  • Plug-in construction designed for the ABB SMISSLINE TP system.
  • Compact two-module design for space-efficient electrical distribution assemblies.

Key Features

  • ABB S400M UC / SMISSLINE TP series.
  • 32 A rated current.
  • 2 protected poles.
  • Type C / UC-C tripping characteristic.
  • 440 V DC maximum two-pole application voltage.
  • Designed for overload and short-circuit protection.
  • SMISSLINE TP plug-in connection system.
  • Compact two-module construction.
  • Suitable for industrial, commercial and automation distribution systems.

Reliable Protection for DC Circuits

DC miniature circuit breakers such as the ABB S402M-UCC32 protect electrical conductors and connected equipment by automatically interrupting current when overload or short-circuit conditions occur. Correctly specified DC switching capability is particularly important because direct current behaves differently from alternating current when an electrical arc is interrupted.

The ABB S400M UC range extends the SMISSLINE TP platform to flexible AC and DC circuit protection applications. The S402M-UCC32 combines a Type C characteristic, two protected poles and a 32 A current rating with the installation advantages of ABB's modular plug-in distribution system.

Typical Applications

  • Industrial DC distribution systems.
  • Automation and machine control circuits.
  • DC control and auxiliary power circuits.
  • Industrial electrical distribution cabinets.
  • Equipment with moderate starting or inrush currents.
  • Commercial and industrial power distribution.
  • ABB SMISSLINE TP modular distribution assemblies.

Technical Specifications

Series S400M UC / SMISSLINE TP
ABB order code 2CCS572001R1324
Product type DC miniature circuit breaker (MCB)
Rated current 32 A
Number of poles 2
Number of protected poles 2
Tripping characteristic Type C / UC-C
Maximum DC voltage, two-pole connection 440 V DC
Mounting type SMISSLINE TP plug-in system
Width in modules 2
Weight approx. 0.221 kg
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S402M-UCC32 used for?

The S402M-UCC32 is a 2-pole miniature circuit breaker designed to protect compatible DC electrical circuits against overloads and short circuits.

What is the current rating of the S402M-UCC32?

The ABB S402M-UCC32 has a rated current of 32 A.

What tripping characteristic does the S402M-UCC32 use?

The breaker uses a Type C / UC-C tripping characteristic, making it suitable for general-purpose circuits and appropriate loads with moderate starting or inrush currents.

What DC voltage can the ABB S402M-UCC32 be used with?

The S402M-UCC32 supports two-pole applications up to 440 V DC when connected in accordance with ABB's specified arrangement.

How is the ABB S402M-UCC32 installed?

The breaker is designed for plug-in installation within the ABB SMISSLINE TP system, enabling efficient integration into compatible modular electrical distribution assemblies.

Trusted ABB DC Circuit Protection

ABB S400M UC miniature circuit breakers provide dependable overload and short-circuit protection for DC and AC applications while combining robust electrical performance with the modular advantages of the SMISSLINE TP plug-in distribution system.