2CCS572001R1258 ABB S402M-UCZ25 Miniature Circuit Breaker 25 A 2P Type Z 10 kA

2CCS572001R1258 ABB S402M-UCZ25 Miniature Circuit Breaker 25 A 2P Type Z 10 kA

ABB S402M-UCZ25 is a 25 A 2-pole Type Z AC/DC miniature circuit breaker with 10 kA breaking capacity, designed for overload and short-circuit protection in SMISSLINE TP plug-in distribution systems.

SKU: 2CCS572001R1258Alt SKU: S402MUCZ25MPN: 2CCS572001R1258
Price
List Price £191.54 ex VAT
Your Price (ex VAT) Save 35%
£124.50 35% OFF
You save £67.04 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £124.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£124.50

Why Choose the ABB S402M-UCZ25 DC Miniature Circuit Breaker?

The ABB S402M-UCZ25 is a high-performance 2-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in DC and AC electrical distribution systems. As part of the ABB S400M UC / SMISSLINE TP series, it combines a 25 A rated current, Type Z tripping characteristic and 10 kA breaking capacity with convenient plug-in installation.

Designed for circuits requiring sensitive overcurrent protection, the S402M-UCZ25 uses a UC-Z characteristic suited to applications where rapid magnetic response is required at relatively low multiples of rated current. Its two protected poles and SMISSLINE TP plug-in construction support efficient integration into compatible modular distribution assemblies.

With a 25 A rated current, 2-pole configuration and support for two-pole DC applications up to 440 V DC, the S402M-UCZ25 is suitable for industrial control, automation and power distribution circuits. Its compact 36 mm width and robust construction make it well suited to commercial, industrial and critical-power installations.

Key Advantages

  • Reliable 2-pole miniature circuit breaker for overload and short-circuit protection.
  • 25 A rated current for control and distribution circuits.
  • Type Z / UC-Z tripping characteristic for sensitive electrical loads.
  • Suitable for AC and DC circuit protection.
  • Two-pole DC operation up to 440 V DC.
  • 10 kA breaking capacity for dependable fault protection.
  • Plug-in construction designed specifically for the ABB SMISSLINE TP system.

Key Features

  • ABB S400M UC / SMISSLINE TP series.
  • 25 A rated current.
  • 2 protected poles.
  • Type Z / UC-Z tripping characteristic.
  • AC/DC voltage type.
  • 440 V DC maximum two-pole application voltage.
  • 10 kA breaking capacity.
  • 4 kV rated impulse withstand voltage.
  • Energy limiting class 3.
  • Compact two-module SMISSLINE plug-in construction.

Reliable Protection for AC and DC Circuits

Miniature circuit breakers such as the ABB S402M-UCZ25 protect electrical conductors and connected equipment by automatically interrupting current when overload or short-circuit conditions occur. Correctly specified switching capability is particularly important in DC systems because direct current behaves differently from alternating current when a fault current is interrupted.

The ABB S400M UC range extends the established SMISSLINE TP platform with circuit breakers developed for flexible AC and DC applications. The S402M-UCZ25 combines sensitive UC-Z protection, two protected poles and high short-circuit performance with the installation advantages of ABB's modular plug-in distribution system.

Typical Applications

  • Industrial DC distribution systems.
  • Automation and machine control circuits.
  • DC control and auxiliary power circuits.
  • Sensitive electrical and electronic equipment protection.
  • Commercial and industrial power distribution.
  • Critical-power distribution systems.
  • ABB SMISSLINE TP modular distribution assemblies.

Technical Specifications

Series S400M UC / SMISSLINE TP
ABB order code 2CCS572001R1258
EAN 7612270110377
Product type Miniature circuit breaker (MCB)
Rated current 25 A
Number of poles 2
Number of protected poles 2
Tripping characteristic Type Z / UC-Z
Voltage type AC/DC
Maximum DC voltage, two-pole connection 440 V DC
Breaking capacity 10 kA
Frequency 50–60 Hz
Rated impulse withstand voltage 4 kV
Energy limiting class 3
Overvoltage category III
Pollution degree 2
Operating temperature -25 to +60 °C
Mounting type SMISSLINE TP plug-in system
Conductor connection range, stranded 0.75–25 mm²
Conductor connection range, solid 0.75–35 mm²
Width 36 mm
Height 91 mm
Depth 75 mm
Width in modules 2
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S402M-UCZ25 used for?

The S402M-UCZ25 is a 2-pole miniature circuit breaker designed to protect compatible AC and DC electrical circuits against overloads and short circuits.

What is the current rating of the S402M-UCZ25?

The ABB S402M-UCZ25 has a rated current of 25 A.

What tripping characteristic does the S402M-UCZ25 use?

The breaker uses a Type Z / UC-Z tripping characteristic, making it suitable for sensitive circuits requiring rapid response to overcurrent conditions.

What DC voltage can the ABB S402M-UCZ25 be used with?

The S402M-UCZ25 supports two-pole applications up to 440 V DC when connected in accordance with ABB's specified arrangement.

How is the ABB S402M-UCZ25 installed?

The breaker is designed exclusively for plug-in installation within the ABB SMISSLINE TP system, enabling efficient integration into compatible modular electrical distribution assemblies.

Trusted ABB AC/DC Circuit Protection

ABB S400M UC miniature circuit breakers provide dependable overload and short-circuit protection for AC and DC applications while combining specialised tripping characteristics with the modular advantages of the SMISSLINE TP plug-in distribution system.