2CCS572001R1254 ABB S402M-UCC25 MCB AC/DC 2P Type C 25A

2CCS572001R1254 ABB S402M-UCC25 MCB AC/DC 2P Type C 25A

ABB S402M-UCC25 is a 25 A UC-C Type C 2-pole AC/DC miniature circuit breaker with 10 kA short-circuit breaking capacity, designed for reliable overload and short-circuit protection in SMISSLINE TP plug-in systems.

SKU: 2CCS572001R1254Alt SKU: S402MUCC25MPN: 2CCS572001R1254
Price
List Price £160.61 ex VAT
Your Price (ex VAT) Save 35%
£104.40 35% OFF
You save £56.21 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £104.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£104.40

Why Choose the ABB S402M-UCC25 AC/DC Miniature Circuit Breaker?

The ABB S402M-UCC25 is a 2-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in AC and DC electrical systems. Part of the ABB S400M-UC range for the SMISSLINE TP plug-in system, it combines a 25 A rated current, UC-C / Type C characteristic and 10 kA short-circuit breaking capacity.

The S402M-UCC25 uses thermal and electromagnetic tripping principles to protect cables and connected circuits against sustained overloads and short-circuit faults. Its Type C characteristic accommodates moderate starting and inrush currents, making it suitable for appropriately designed industrial, commercial, control and auxiliary circuits.

Designed for flexible AC and DC applications, the S402M-UCC25 can be used in two-pole DC circuits up to 440 V DC when connected in accordance with ABB's specified connection arrangement. Its 400 V AC rating, IP20 protection and compact 36 × 91 × 75 mm construction make it a versatile protective device for compatible SMISSLINE TP distribution systems.

Key Advantages

  • 25 A rated current for dependable protection of appropriately rated circuits.
  • 2-pole configuration for coordinated AC and DC circuit protection.
  • UC-C / Type C characteristic suited to circuits with moderate starting or inrush currents.
  • 10 kA short-circuit breaking capacity for robust fault protection.
  • Supports two-pole DC applications up to 440 V DC when connected according to ABB requirements.
  • Purpose-designed for the ABB SMISSLINE TP plug-in system.

Key Features

  • ABB S400M-UC series miniature circuit breaker.
  • 25 A nominal current rating.
  • UC-C / Type C tripping characteristic.
  • 2 protected poles.
  • Suitable for AC and DC applications.
  • 400 V AC rated voltage.
  • Two-pole DC operation up to 440 V DC.
  • 10 kA short-circuit breaking capacity.
  • 4 kV rated impulse withstand voltage.
  • IP20 degree of protection.
  • 10,000-cycle electrical endurance.
  • SMISSLINE TP plug-in mounting for compatible distribution systems.

Reliable Protection for AC and DC Circuits

The ABB S402M-UCC25 protects electrical circuits against excessive current caused by overloads and short circuits. Its thermal release responds to sustained overload conditions, while the electromagnetic release provides rapid interruption during short-circuit faults, helping protect cables, equipment and downstream circuitry.

The S400M-UC platform extends ABB's SMISSLINE TP system with flexible protection for both AC and DC applications. With its 25 A Type C characteristic, 10 kA breaking capacity and two-pole DC capability up to 440 V DC, the S402M-UCC25 provides a versatile solution for industrial control, auxiliary and power-distribution circuits.

Typical Applications

  • ABB SMISSLINE TP electrical distribution systems.
  • Industrial AC and DC control circuits.
  • Automation and machine-control systems.
  • DC auxiliary power distribution.
  • Commercial and industrial switchboards.
  • Equipment circuits requiring 25 A Type C overcurrent protection.

Technical Specifications

Series S400M-UC / SMISSLINE TP
ABB order code 2CCS572001R1254
EAN 7612270110032
Product type AC/DC miniature circuit breaker (MCB)
Number of poles 2
Number of protected poles 2
Rated current 25 A
Tripping characteristic UC-C / Type C
Rated AC voltage 400 V AC
Maximum two-pole DC voltage 440 V DC
Rated short-circuit breaking capacity 10 kA
Ultimate short-circuit breaking capacity (Icu) at 230 V AC 25 kA
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 10 kA
Rated insulation voltage (Ui) 440 V
Rated impulse withstand voltage (Uimp) 4 kV
Energy limiting class 3
Protection rating IP20
Electrical endurance 10,000 cycles
Power loss 5.4 W
Conductor connection range 0.75–35 mm²
Mounting type SMISSLINE TP plug-in
Width 2 modules / 36 mm
Height 91 mm
Depth 75 mm
Net weight approx. 221 g
Operating temperature −25 to +60 °C
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S402M-UCC25 used for?

The ABB S402M-UCC25 is a 2-pole miniature circuit breaker designed to provide overload and short-circuit protection for appropriately rated AC and DC circuits within compatible ABB SMISSLINE TP systems.

What is the current rating of the S402M-UCC25?

The S402M-UCC25 has a rated current of 25 A.

What does the UC-C / Type C characteristic mean?

The UC-C / Type C characteristic accommodates moderate starting and inrush currents, making the breaker suitable for appropriately designed industrial, commercial, automation and control circuits.

Can the ABB S402M-UCC25 be used on DC circuits?

Yes. The S402M-UCC25 belongs to ABB's S400M-UC range and supports two-pole applications up to 440 V DC when connected according to ABB's specified DC connection arrangement.

What is the breaking capacity of the S402M-UCC25?

The S402M-UCC25 has a 10 kA rated short-circuit breaking capacity, with an ultimate short-circuit breaking capacity of 25 kA at 230 V AC and 10 kA at 400 V AC.

Trusted ABB AC/DC Circuit Protection

ABB S400M-UC protective devices combine flexible AC/DC circuit protection, robust short-circuit performance and SMISSLINE TP plug-in technology for dependable industrial and commercial electrical distribution.