2CCS572001R0501 ABB S402M-D50 50 A 2-Pole Type D Miniature Circuit Breaker

2CCS572001R0501 ABB S402M-D50 50 A 2-Pole Type D Miniature Circuit Breaker

ABB S402M-D50 is a 50 A 2-pole Type D miniature circuit breaker for the SMISSLINE plug-in system, providing overload and short-circuit protection with a 10 kA breaking capacity at 400 V AC.

SKU: 2CCS572001R0501Alt SKU: S402MD50MPN: 2CCS572001R0501
Price
List Price £145.85 ex VAT
Your Price (ex VAT) Save 35%
£94.80 35% OFF
You save £51.05 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £94.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£94.80

Why Choose the ABB S402M-D50 Miniature Circuit Breaker?

The ABB S402M-D50 is a robust and reliable 2-pole miniature circuit breaker (MCB) designed to provide overload and short-circuit protection in industrial and commercial electrical distribution systems. As part of the ABB S400M / SMISSLINE plug-in system, it combines dependable circuit protection with convenient plug-in installation for modular distribution assemblies.

This circuit breaker has a rated current of 50 A and a Type D tripping characteristic, making it particularly suitable for circuits supplying equipment with high starting or inrush currents. Its two-pole configuration provides simultaneous protection of two conductors, while the SMISSLINE plug-in design helps simplify installation, replacement and maintenance within compatible ABB distribution systems.

With a rated short-circuit breaking capacity of 10 kA to IEC/EN 60898-1 and a rated operational voltage of 400 V AC, the S402M-D50 is suitable for demanding electrical distribution and machinery applications. Its compact 36 mm width, IP20 protection and proven ABB construction make it a practical solution for professional control panels and distribution boards.

Key Advantages

  • Reliable 2-pole miniature circuit breaker for overload and short-circuit protection.
  • 50 A rated current for higher-current distribution circuits.
  • Type D tripping characteristic suitable for loads with high starting and inrush currents.
  • 10 kA short-circuit breaking capacity to IEC/EN 60898-1.
  • 400 V AC rated operational voltage for industrial electrical systems.
  • Designed for the ABB SMISSLINE plug-in system for efficient installation and replacement.
  • Compact 2-module design helps optimise distribution-board space.
  • Robust construction for demanding industrial and commercial installations.

Key Features

  • ABB S400M / SMISSLINE series.
  • 50 A rated current.
  • 2-pole configuration.
  • Type D tripping characteristic.
  • 10 kA rated short-circuit breaking capacity to IEC/EN 60898-1.
  • 400 V AC rated operational voltage.
  • IP20 degree of protection.
  • Plug-in SMISSLINE mounting for modular distribution systems.
  • Compact 36 × 91 × 75 mm enclosure.

Reliable Circuit Protection for High-Inrush Loads

Miniature circuit breakers such as the ABB S402M-D50 automatically disconnect a circuit when excessive current occurs because of an overload or short circuit. This helps protect conductors, connected equipment and electrical installations from damage while allowing the breaker to be reset after the underlying fault has been corrected.

The Type D characteristic is particularly suited to circuits containing equipment that can draw substantial transient currents during start-up. Combined with ABB's SMISSLINE plug-in architecture, the S402M-D50 provides effective circuit protection while supporting efficient installation and maintenance in compatible modular distribution systems.

Typical Applications

  • Industrial electrical distribution boards.
  • Machine control panels and automation systems.
  • Circuits supplying motors with high starting currents.
  • Transformers and other high-inrush electrical loads.
  • Industrial production and processing machinery.
  • Commercial electrical distribution systems.
  • OEM machinery and control equipment.
  • ABB SMISSLINE modular distribution assemblies.

Technical Specifications

Product group SMISSLINE Plug-in System
Series S400M
ABB order code 2CCS572001R0501
Product type Miniature circuit breaker (MCB)
Rated current 50 A
Number of poles 2
Tripping characteristic Type D
Rated short-circuit breaking capacity 10 kA to IEC/EN 60898-1
Rated operational voltage 400 V AC
Protection rating IP20
Mounting type Plug-in SMISSLINE
Module width 2 modules
Width 36 mm
Height 91 mm
Depth 75 mm
Dimensions (W × H × D) 36 × 91 × 75 mm
Weight approx. 221 g
Operating ambient temperature -25 to +55 °C
Standard IEC/EN 60898-1

Frequently Asked Questions

What is the ABB S402M-D50 used for?

The ABB S402M-D50 is a 2-pole miniature circuit breaker designed to protect electrical circuits against overload and short-circuit currents, particularly in industrial and commercial applications with high-inrush loads.

What is the current rating of the S402M-D50?

The S402M-D50 has a rated current of 50 A.

What does the Type D tripping characteristic mean?

The Type D tripping characteristic accommodates relatively high short-duration starting and inrush currents, making this MCB suitable for appropriate circuits supplying equipment such as motors and transformers.

What is the breaking capacity of the ABB S402M-D50?

The S402M-D50 has a rated short-circuit breaking capacity of 10 kA to IEC/EN 60898-1.

How is the ABB S402M-D50 installed?

The S402M-D50 is designed for plug-in installation within compatible ABB SMISSLINE distribution systems, helping simplify the installation and replacement of protective devices.

Trusted ABB Circuit Protection

ABB SMISSLINE miniature circuit breakers provide dependable overload and short-circuit protection for professional electrical distribution systems, combining proven protective technology with the flexibility and convenience of a modular plug-in platform.