2CCS572001R0084 ABB S402M-C8 MCB 8 A Type C 10 kA 2P

2CCS572001R0084 ABB S402M-C8 MCB 8 A Type C 10 kA 2P

ABB S402M-C8 is an 8 A Type C 2-pole miniature circuit breaker with 10 kA rated short-circuit breaking capacity and SMISSLINE TP plug-in mounting for commercial and industrial electrical distribution systems.

SKU: 2CCS572001R0084Alt SKU: S402MC8MPN: 2CCS572001R0084
Price
List Price £96.01 ex VAT
Your Price (ex VAT) Save 35%
£62.41 35% OFF
You save £33.60 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £62.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£62.41

Why Choose the ABB S402M-C8 Miniature Circuit Breaker?

The ABB S402M-C8 is a compact, current-limiting miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in commercial and industrial electrical distribution systems. As part of the ABB SMISSLINE TP S400M series, it combines dependable two-pole protection with the modular plug-in installation advantages of the SMISSLINE system.

This circuit breaker uses thermal and electromagnetic tripping to protect wiring and connected equipment against overcurrents. Its Type C tripping characteristic is suitable for general-purpose circuits and compatible electrical loads with moderate starting or inrush currents.

With a rated current of 8 A, a rated operational voltage of 415 V AC and a 10 kA rated short-circuit breaking capacity, the S402M-C8 provides dependable two-pole circuit protection. Its SMISSLINE TP plug-in design enables straightforward integration into compatible ABB modular distribution systems.

Key Advantages

  • Compact 2-pole miniature circuit breaker for SMISSLINE TP systems.
  • 8 A rated current for low-current circuit protection.
  • Type C tripping characteristic for compatible loads with moderate starting or inrush currents.
  • 10 kA rated short-circuit breaking capacity.
  • 25 kA Icu ultimate short-circuit breaking capacity at 415 V AC.
  • Both poles are protected for comprehensive two-pole circuit protection.
  • Plug-in SMISSLINE mounting supports efficient installation, replacement and system expansion.

Key Features

  • ABB SMISSLINE TP S400M series.
  • 8 A rated current.
  • 415 V AC rated operational voltage.
  • Type C trip characteristic.
  • 2-pole configuration with both poles protected.
  • 10 kA rated short-circuit breaking capacity.
  • 25 kA Icu ultimate short-circuit breaking capacity at 415 V AC.
  • IP20 protection rating.
  • 10,000-cycle electrical endurance.
  • Complies with IEC/EN 60898-1 and IEC/EN 60947-2.
  • Two-module SMISSLINE plug-in format.

Reliable Two-Pole Protection for Electrical Distribution Systems

Miniature circuit breakers such as the ABB S402M-C8 protect electrical wiring and connected equipment against excessive current. Thermal tripping responds to sustained overload conditions, while electromagnetic tripping provides rapid disconnection during short-circuit faults.

The Type C characteristic makes the S402M-C8 suitable for general-purpose circuits and compatible equipment with moderate inrush currents. Combined with ABB’s SMISSLINE TP plug-in architecture and two protected poles, it provides a practical protection solution for commercial and industrial electrical distribution applications.

Typical Applications

  • Commercial electrical distribution boards.
  • Industrial control and automation panels.
  • Low-current two-pole circuits.
  • Control and auxiliary power circuits.
  • Machine and equipment electrical distribution.
  • Circuits supplying compatible moderate-inrush loads.
  • SMISSLINE TP modular distribution systems.

Technical Specifications

Series SMISSLINE TP S400M
ABB order code 2CCS572001R0084
EAN 7612270102167
Product type Miniature circuit breaker (MCB)
Rated current 8 A
Rated operational voltage 415 V AC
Trip characteristic Type C
Pole configuration 2P
Number of protected poles 2
Rated short-circuit breaking capacity 10 kA
Ultimate short-circuit breaking capacity Icu 25 kA at 415 V AC
Protection rating IP20
Applicable standards IEC/EN 60898-1 and IEC/EN 60947-2
Mounting type Plug-in SMISSLINE TP
Module width 2 modules
Conductor connection capacity 0.75–35 mm²
Electrical endurance 10,000 cycles
Operating ambient temperature -25 to +60 °C
Dimensions (W × H × D) 36 × 91 × 75 mm
Weight approx. 221 g

Frequently Asked Questions

What is the ABB S402M-C8 used for?

The S402M-C8 provides overload and short-circuit protection for compatible two-pole electrical circuits in ABB SMISSLINE TP commercial and industrial distribution systems.

What is the rated current of the S402M-C8?

The S402M-C8 has a rated current of 8 A.

What tripping characteristic does the S402M-C8 use?

The breaker uses a Type C tripping characteristic, making it suitable for general-purpose circuits and compatible loads with moderate starting or inrush currents.

What is the breaking capacity of the S402M-C8?

The S402M-C8 has a rated short-circuit breaking capacity of 10 kA and an ultimate short-circuit breaking capacity of 25 kA at 415 V AC.

How is the ABB S402M-C8 installed?

The breaker uses ABB’s SMISSLINE TP plug-in system, allowing it to be integrated into compatible modular SMISSLINE electrical distribution assemblies.

Trusted Electrical Protection from ABB

ABB SMISSLINE TP miniature circuit breakers provide dependable overload and short-circuit protection while supporting modular plug-in installation for commercial and industrial electrical distribution applications.