2CCS571103R8467 ABB S401M-K16NP MCB 10kA 1P+NP Type K 16A

2CCS571103R8467 ABB S401M-K16NP MCB 10kA 1P+NP Type K 16A

ABB S401M-K16NP is a 16 A 1P+NP Type K miniature circuit breaker with protected neutral, 10 kA rated breaking capacity and SMISSLINE TP plug-in mounting for reliable overload and short-circuit protection.

SKU: 2CCS571103R8467Alt SKU: S401MK16NPMPN: 2CCS571103R8467
Price
List Price £91.32 ex VAT
Your Price (ex VAT) Save 35%
£59.36 35% OFF
You save £31.96 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £59.36
Trade pricing is personalised to your account

Manufacturer Lead Time

£59.36

Why Choose the ABB S401M-K16NP Miniature Circuit Breaker?

The ABB S401M-K16NP is a pluggable 1P+NP miniature circuit breaker (MCB) with protected neutral designed to protect electrical circuits and conductors against overload and short-circuit currents. Part of the ABB S400M-K SMISSLINE TP series, it combines robust circuit protection with the flexibility of ABB's modular plug-in power distribution system.

This circuit breaker has a rated current of 16 A, a Type K tripping characteristic and a rated short-circuit breaking capacity of 10 kA. For the 16 A S401M-K16NP, ABB specifies an ultimate short-circuit breaking capacity of 25 kA, providing substantial fault-current capability for appropriately designed professional electrical installations.

The S401M-K16NP incorporates a protected neutral, with the neutral protected at 100% of the nominal value of the pole conductor. Its compact 2-module construction and SMISSLINE plug-in mounting support efficient installation, replacement and system expansion in compatible ABB distribution assemblies.

Key Advantages

  • 16 A rated current with Type K tripping characteristic.
  • 1P+NP configuration with protected neutral.
  • 10 kA rated short-circuit breaking capacity.
  • 25 kA ultimate short-circuit breaking capacity for the 16 A model.
  • Type K characteristic suited to appropriately designed circuits with elevated starting currents.
  • Neutral conductor protected at 100% of the nominal value of the pole conductor.
  • Plug-in construction for integration with the ABB SMISSLINE TP system.

Key Features

  • ABB S400M-K SMISSLINE TP miniature circuit breaker.
  • 16 A rated current.
  • Type K characteristic.
  • 1P+NP protected-neutral configuration.
  • 240 V AC rated voltage.
  • 10 kA rated short-circuit breaking capacity.
  • 25 kA ultimate short-circuit breaking capacity.
  • IP20 degree of protection.
  • 2-module format.
  • SMISSLINE plug-in mounting for modular electrical distribution.

Reliable Type K Protection for Circuits with Starting Currents

The ABB S401M-K16NP protects electrical conductors and connected equipment by automatically interrupting excessive currents caused by overload and short-circuit conditions. Its current-limiting design helps restrict fault energy, while the protected-neutral configuration extends overcurrent protection to the neutral conductor.

The Type K characteristic is particularly useful for appropriately engineered circuits where elevated short-duration starting currents may occur, including certain motor, transformer and inductive-load applications. Combined with ABB's SMISSLINE TP plug-in architecture, the S401M-K16NP provides a compact and maintainable circuit-protection solution for professional electrical distribution.

Typical Applications

  • Industrial electrical distribution systems.
  • Machine and automation control panels.
  • Motor circuits where Type K protection is appropriate.
  • Transformer and inductive-load circuits.
  • Control and auxiliary power distribution.
  • Circuits subject to elevated short-duration starting currents.
  • ABB SMISSLINE TP plug-in distribution assemblies.

Technical Specifications

Product group SMISSLINE Plug-in System
Series S400M-K / SMISSLINE TP
ABB order code 2CCS571103R8467
EAN 7612270103713
Product type Miniature circuit breaker (MCB)
Rated current 16 A
Tripping characteristic Type K
Configuration 1P+NP with protected neutral
Total number of poles 2
Rated voltage 240 V AC
Rated short-circuit breaking capacity 10 kA
Ultimate short-circuit breaking capacity (Icu) 25 kA
Protection rating IP20
Current limiting class 3
Overvoltage category III
Pollution degree 3
Operating temperature from −25 °C
Number of modules 2
Mounting type SMISSLINE plug-in
Dimensions (W × H × D) 36 × 91 × 75 mm
Weight approx. 221 g
ABB packaging unit 5 pieces

Frequently Asked Questions

What is the ABB S401M-K16NP used for?

The S401M-K16NP is a 16 A miniature circuit breaker designed to protect electrical circuits against overload and short-circuit currents, particularly where a Type K tripping characteristic is required.

What is the rated current of the S401M-K16NP?

The ABB S401M-K16NP has a rated current of 16 A.

What does the Type K characteristic mean?

The Type K characteristic is suited to appropriately designed circuits where elevated short-duration starting currents can occur, including certain motor, transformer and other inductive-load applications.

What is the breaking capacity of the S401M-K16NP?

The S401M-K16NP has a rated short-circuit breaking capacity of 10 kA and an ultimate short-circuit breaking capacity of 25 kA.

Does the S401M-K16NP have a protected neutral?

Yes. The S401M-K16NP has a protected neutral, with the neutral protected at 100% of the nominal value of the pole conductor.

Trusted ABB Protection for Professional Distribution Systems

ABB SMISSLINE TP S400M-K miniature circuit breakers combine robust Type K circuit protection with a protected-neutral configuration and flexible plug-in architecture for professional low-voltage power distribution.