2CCS571103R8324 ABB S401M-C32NP MCB 10kA 1P+NP Type C 32A

2CCS571103R8324 ABB S401M-C32NP MCB 10kA 1P+NP Type C 32A

ABB S401M-C32NP is a 32 A 1P+NP Type C miniature circuit breaker with protected neutral and 10 kA breaking capacity for reliable overload and short-circuit protection in SMISSLINE TP plug-in distribution systems.

SKU: 2CCS571103R8324Alt SKU: S401MC32NPMPN: 2CCS571103R8324
Price
List Price £89.88 ex VAT
Your Price (ex VAT) Save 35%
£58.42 35% OFF
You save £31.46 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £58.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£58.42

Why Choose the ABB S401M-C32NP Miniature Circuit Breaker?

The ABB S401M-C32NP is a current-limiting 1P+NP miniature circuit breaker (MCB) with protected neutral designed to provide reliable overload and short-circuit protection in electrical distribution systems. As part of the ABB S400M SMISSLINE TP plug-in series, it combines dependable circuit protection with a modular plug-in architecture for professional commercial and industrial power distribution.

This circuit breaker has a rated current of 32 A, a Type C tripping characteristic and a rated short-circuit breaking capacity of 10 kA according to IEC/EN 60898-1. It also has a rated ultimate short-circuit breaking capacity of 15 kA according to IEC/EN 60947-2, providing robust protection for demanding distribution applications.

The S401M-C32NP uses an L+N configuration with protected neutral, with the neutral protected at 100% of the nominal value of the pole conductor. Its compact 2-module plug-in format enables straightforward integration into compatible ABB SMISSLINE TP assemblies, supporting efficient installation, maintenance and circuit expansion.

Key Advantages

  • Compact 1P+NP miniature circuit breaker with protected neutral.
  • 32 A rated current for branch and final circuit protection.
  • Type C tripping characteristic suitable for circuits with moderate starting and inrush currents.
  • 10 kA rated short-circuit breaking capacity according to IEC/EN 60898-1.
  • 15 kA rated ultimate short-circuit breaking capacity according to IEC/EN 60947-2.
  • Neutral conductor is protected at 100% of the nominal value of the pole conductor.
  • Plug-in construction for efficient integration with the ABB SMISSLINE TP system.

Key Features

  • ABB S400M SMISSLINE TP miniature circuit breaker series.
  • 32 A rated current.
  • Type C characteristic.
  • 1P+NP / L+N configuration with protected neutral.
  • 10 kA Icn short-circuit breaking capacity.
  • 15 kA Icu ultimate short-circuit breaking capacity.
  • Delayed thermal tripping mechanism for overload protection.
  • Electromagnetic tripping mechanism for short-circuit protection.
  • Compliant with IEC/EN 60898-1 and IEC/EN 60947-2.
  • 2-module SMISSLINE TP plug-in format.

Reliable Overload and Short-Circuit Protection

Miniature circuit breakers such as the ABB S401M-C32NP protect electrical conductors and connected equipment by automatically interrupting excessive current. The S400M design incorporates a delayed thermal tripping mechanism for overload protection together with an electromagnetic mechanism for rapid short-circuit protection.

The Type C characteristic accommodates moderate short-duration starting currents while maintaining dependable fault protection. Combined with its protected neutral and ABB's SMISSLINE TP plug-in architecture, the S401M-C32NP provides a practical solution for modular, maintainable and reliable professional power distribution.

Typical Applications

  • Commercial electrical distribution systems.
  • Industrial power distribution boards.
  • Machine and automation control panels.
  • General-purpose final circuits.
  • Control and auxiliary electrical circuits.
  • Circuits with moderate starting or inrush currents.
  • ABB SMISSLINE TP plug-in distribution assemblies.

Technical Specifications

Product group SMISSLINE Plug-in System
Series S400M / SMISSLINE TP
ABB order code 2CCS571103R8324
EAN 7612270103485
Product type Miniature circuit breaker (MCB)
Rated current 32 A
Tripping characteristic Type C
Configuration 1P+NP / L+N with protected neutral
Rated voltage 230 / 400 V AC
Frequency 50–60 Hz
Rated short-circuit breaking capacity (Icn) 10 kA
Rated ultimate short-circuit breaking capacity (Icu) 15 kA
Standards IEC/EN 60898-1 and IEC/EN 60947-2
Protection rating IP20
Number of modules 2
Mounting type SMISSLINE TP plug-in
Dimensions (H × W × D) 91 × 36 × 82 mm
Weight approx. 221 g
Packaging unit 5 pieces

Frequently Asked Questions

What is the ABB S401M-C32NP used for?

The S401M-C32NP is a miniature circuit breaker designed to protect electrical circuits against overload and short-circuit currents in commercial, industrial and other professional distribution applications.

What is the rated current of the S401M-C32NP?

The ABB S401M-C32NP has a rated current of 32 A.

What does the Type C characteristic mean?

The Type C tripping characteristic accommodates moderate starting and inrush currents while providing dependable overload and short-circuit protection.

What is the breaking capacity of the S401M-C32NP?

The S401M-C32NP has a rated short-circuit breaking capacity of 10 kA according to IEC/EN 60898-1 and a rated ultimate short-circuit breaking capacity of 15 kA according to IEC/EN 60947-2.

Is the neutral conductor protected by the S401M-C32NP?

Yes. The S401M-C32NP has a protected neutral, with the neutral protected at 100% of the nominal value of the pole conductor.

Trusted ABB Protection for Professional Distribution Systems

ABB SMISSLINE TP S400M miniature circuit breakers combine dependable overload and short-circuit protection with a flexible plug-in architecture for efficient commercial and industrial power distribution.