2CCS571103R8044 ABB S401M-C4NP Miniature Circuit Breaker 4 A Type C 1P+N

2CCS571103R8044 ABB S401M-C4NP Miniature Circuit Breaker 4 A Type C 1P+N

ABB S401M-C4NP is a 4 A Type C 1P+N miniature circuit breaker with protected neutral for the SMISSLINE TP plug-in system, providing a 10 kA rated short-circuit capacity and 25 kA ultimate breaking capacity.

SKU: 2CCS571103R8044Alt SKU: S401MC4NPMPN: 2CCS571103R8044
Price
List Price £96.86 ex VAT
Your Price (ex VAT) Save 35%
£62.96 35% OFF
You save £33.90 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £62.96
Trade pricing is personalised to your account

Manufacturer Lead Time

£62.96

Why Choose the ABB S401M-C4NP Miniature Circuit Breaker?

The ABB S401M-C4NP is a pluggable 1P+N miniature circuit breaker (MCB) with protected neutral, designed to provide reliable overload and short-circuit protection within the ABB SMISSLINE TP system. Its two-pole configuration combines phase and protected-neutral functionality in a compact device for professional electrical distribution.

Featuring a 4 A rated current and Type C tripping characteristic, the S401M-C4NP is well suited to low-current control, auxiliary and final circuits that can experience moderate starting or inrush currents. It provides a rated short-circuit capacity of 10 kA according to IEC/EN 60898-1 and an ultimate short-circuit breaking capacity of 25 kA according to IEC/EN 60947-2.

With a rated operational voltage of 240 V AC, 440 V insulation voltage and compact two-module construction, the S401M-C4NP combines robust electrical performance with ABB's convenient SMISSLINE TP plug-in architecture for efficient installation, replacement and maintenance.

Key Advantages

  • 1P+N configuration with protected neutral for comprehensive circuit protection.
  • 4 A rated current suitable for low-current control and auxiliary circuits.
  • Type C tripping characteristic accommodates moderate inrush currents.
  • 10 kA rated short-circuit capacity according to IEC/EN 60898-1.
  • 25 kA ultimate short-circuit breaking capacity according to IEC/EN 60947-2.
  • Plug-in construction for direct integration with the ABB SMISSLINE TP system.

Key Features

  • ABB S400 M-C / SMISSLINE TP series.
  • 4 A rated current.
  • Type C tripping characteristic.
  • 1P+N configuration with protected neutral.
  • 240 V AC rated operational voltage.
  • 10 kA Icn according to IEC/EN 60898-1.
  • 25 kA Icu according to IEC/EN 60947-2.
  • 440 V rated insulation voltage.
  • Compact two-module construction.
  • SMISSLINE TP plug-in mounting.

Protected-Neutral Circuit Protection for SMISSLINE TP Systems

The ABB S401M-C4NP combines phase and protected-neutral functionality in a compact two-pole device. Its thermal-magnetic protection automatically interrupts the circuit during overload and short-circuit conditions, helping protect conductors and connected electrical equipment against damaging overcurrents.

ABB's SMISSLINE TP architecture enables compatible protective devices to be plugged directly into the distribution system, supporting efficient installation and maintenance. With its 4 A rating, Type C characteristic and protected-neutral configuration, the S401M-C4NP is particularly suitable for low-current circuits requiring dependable protection and convenient modular installation.

Typical Applications

  • Low-current final circuits.
  • Industrial control and automation circuits.
  • Auxiliary power supplies.
  • Machine and control panels.
  • SMISSLINE TP distribution assemblies.
  • Commercial and industrial electrical installations.

Technical Specifications

Series S400 M-C / SMISSLINE TP
ABB order code 2CCS571103R8044
EAN 7612270108503
Product type Miniature circuit breaker (MCB) with protected neutral
Pole configuration 1P+N
Total poles 2
Rated current 4 A
Tripping characteristic Type C
Rated operational voltage 240 V AC
Rated insulation voltage (Ui) 440 V
Rated short-circuit capacity (Icn) 10 kA
Ultimate short-circuit breaking capacity (Icu) 25 kA
Mounting system SMISSLINE TP plug-in system
Width 2 modules / approx. 36 mm
Height approx. 91 mm
Depth approx. 75 mm
Weight approx. 221 g
Standards IEC/EN 60898-1, IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S401M-C4NP used for?

The S401M-C4NP is a 1P+N miniature circuit breaker with protected neutral designed to protect low-current circuits against overload and short-circuit conditions within ABB SMISSLINE TP systems.

What is the current rating of the S401M-C4NP?

The ABB S401M-C4NP has a rated current of 4 A.

What tripping characteristic does the S401M-C4NP use?

The S401M-C4NP uses a Type C tripping characteristic, making it suitable for circuits that can experience moderate starting or inrush currents.

Does the ABB S401M-C4NP have a protected neutral?

Yes. The S401M-C4NP uses a 1P+N configuration with protected neutral and occupies two modules within the SMISSLINE TP system.

What is the breaking capacity of the ABB S401M-C4NP?

The S401M-C4NP has a rated short-circuit capacity of 10 kA according to IEC/EN 60898-1 and an ultimate short-circuit breaking capacity of 25 kA according to IEC/EN 60947-2.

Trusted ABB Circuit Protection

ABB SMISSLINE TP miniature circuit breakers combine dependable overload and short-circuit protection with a modular plug-in architecture designed for efficient installation, maintenance and expansion of professional electrical distribution systems.