2CCS571103R8034 ABB S401M-C3NP Miniature Circuit Breaker 3 A Type C 1P+N

2CCS571103R8034 ABB S401M-C3NP Miniature Circuit Breaker 3 A Type C 1P+N

ABB S401M-C3NP is a 3 A Type C 1P+N miniature circuit breaker with protected neutral for the SMISSLINE TP plug-in system, providing a 10 kA rated short-circuit capacity and 25 kA ultimate breaking capacity.

SKU: 2CCS571103R8034Alt SKU: S401MC3NPMPN: 2CCS571103R8034
Price
List Price £96.86 ex VAT
Your Price (ex VAT) Save 35%
£62.96 35% OFF
You save £33.90 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £62.96
Trade pricing is personalised to your account

Manufacturer Lead Time

£62.96

Why Choose the ABB S401M-C3NP Miniature Circuit Breaker?

The ABB S401M-C3NP is a compact 1P+N miniature circuit breaker (MCB) with protected neutral, designed to provide reliable overload and short-circuit protection within the ABB SMISSLINE TP plug-in system. Its two-module configuration combines phase and neutral switching in one device, making it a practical solution for low-current final and control circuits.

Featuring a 3 A rated current and Type C tripping characteristic, the S401M-C3NP is suitable for circuits that can experience moderate starting or inrush currents. The breaker provides a rated short-circuit capacity of 10 kA according to EN 60898-1 and an ultimate short-circuit breaking capacity of 25 kA according to IEC/EN 60947-2.

The S401M-C3NP uses ABB's SMISSLINE TP plug-in architecture for efficient installation and replacement. With its protected neutral configuration, compact two-module width and robust short-circuit performance, it is well suited to professional commercial and industrial distribution systems.

Key Advantages

  • 1P+N configuration with protected neutral for comprehensive circuit protection.
  • 3 A rated current suitable for low-current final, control and auxiliary circuits.
  • Type C tripping characteristic accommodates moderate inrush currents.
  • 10 kA rated short-circuit capacity according to EN 60898-1.
  • 25 kA ultimate short-circuit breaking capacity according to IEC/EN 60947-2.
  • Plug-in construction for integration with the ABB SMISSLINE TP system.

Key Features

  • ABB S400 M-C / SMISSLINE TP series.
  • 3 A rated current.
  • Type C tripping characteristic.
  • 1P+N / two-pole configuration.
  • Protected neutral pole.
  • 10 kA Icn according to EN 60898-1.
  • 25 kA Icu according to IEC/EN 60947-2.
  • 50–60 Hz operating frequency.
  • Compact two-module construction.
  • SMISSLINE TP plug-in mounting.

Protected-Neutral Circuit Protection for SMISSLINE TP Systems

The ABB S401M-C3NP combines phase and protected-neutral circuit protection in a compact two-pole device. During an overload or short-circuit condition, its thermal-magnetic mechanism automatically interrupts the affected circuit, helping protect conductors and connected electrical equipment against damaging overcurrents.

ABB's SMISSLINE TP architecture enables compatible protective devices to be plugged into the distribution system, supporting efficient installation, maintenance and replacement. With its 3 A rating, Type C characteristic and protected-neutral configuration, the S401M-C3NP is particularly suitable for low-current circuits requiring dependable two-pole protection.

Typical Applications

  • Low-current final circuits.
  • Industrial control and automation circuits.
  • Auxiliary power supplies.
  • Machine and control panels.
  • SMISSLINE TP distribution assemblies.
  • Commercial and industrial electrical installations.

Technical Specifications

Series S400 M-C / SMISSLINE TP
ABB order code 2CCS571103R8034
EAN 7612270108497
Product type Miniature circuit breaker (MCB) with protected neutral
Pole configuration 1P+N
Total poles 2
Rated current 3 A
Tripping characteristic Type C
Rated short-circuit capacity (Icn) 10 kA
Ultimate short-circuit breaking capacity (Icu) 25 kA
Frequency 50–60 Hz
Mounting system SMISSLINE TP plug-in system
Width 2 modules / approx. 36 mm
Height approx. 91 mm
Weight approx. 221 g
Standards EN 60898-1, IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S401M-C3NP used for?

The S401M-C3NP is a 1P+N miniature circuit breaker with protected neutral designed to protect low-current circuits against overload and short-circuit conditions within ABB SMISSLINE TP systems.

What is the current rating of the S401M-C3NP?

The ABB S401M-C3NP has a rated current of 3 A.

What tripping characteristic does the S401M-C3NP use?

The S401M-C3NP uses a Type C tripping characteristic, making it suitable for circuits that can experience moderate starting or inrush currents.

Does the ABB S401M-C3NP have a protected neutral?

Yes. The S401M-C3NP is a 1P+N device with protected neutral, providing phase and neutral protection in a compact two-module configuration.

What is the breaking capacity of the ABB S401M-C3NP?

The S401M-C3NP has a rated short-circuit capacity of 10 kA according to EN 60898-1 and an ultimate short-circuit breaking capacity of 25 kA according to IEC/EN 60947-2.

Trusted ABB Circuit Protection

ABB SMISSLINE TP miniature circuit breakers combine dependable overload and short-circuit protection with a modular plug-in architecture designed for efficient installation, maintenance and expansion of professional electrical distribution systems.