2CCS571001R1408 ABB S401M-UCZ40 DC Miniature Circuit Breaker 1P Type Z 40A 10kA

2CCS571001R1408 ABB S401M-UCZ40 DC Miniature Circuit Breaker 1P Type Z 40A 10kA

ABB S401M-UCZ40 is a 40 A single-pole UC-Z Type Z miniature circuit breaker with 10 kA short-circuit capacity, designed for sensitive overload and short-circuit protection in AC/DC and DC SMISSLINE TP plug-in distribution systems.

SKU: 2CCS571001R1408Alt SKU: S401MUCZ40MPN: 2CCS571001R1408
Price
List Price £96.22 ex VAT
Your Price (ex VAT) Save 35%
£62.54 35% OFF
You save £33.68 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £62.54
Trade pricing is personalised to your account

Manufacturer Lead Time

£62.54

Why Choose the ABB S401M-UCZ40 Miniature Circuit Breaker?

The ABB S401M-UCZ40 is a pluggable single-pole miniature circuit breaker (MCB) designed for reliable overload and short-circuit protection in AC/DC and DC applications within ABB SMISSLINE TP electrical distribution systems. Part of the ABB S400 M-UC series, it combines robust circuit protection with the flexible plug-in architecture of the SMISSLINE TP system.

Rated at 40 A, the S401M-UCZ40 features a UC-Z / Type Z tripping characteristic according to IEC/EN 60947-2. Its thermal protection responds to sustained overload conditions, while the sensitive Type Z electromagnetic characteristic provides rapid operation during short-circuit faults, making the breaker suitable for appropriately engineered circuits requiring sensitive overcurrent protection.

For DC applications, the single-pole S401M-UCZ40 can be used at up to 220 V DC in the specified connection arrangement. With a 10 kA rated short-circuit capacity, compact one-module construction and SMISSLINE TP plug-in connection, it provides dependable protection for industrial control, automation and distribution systems.

Key Advantages

  • Reliable overload and short-circuit protection for AC/DC and DC circuits.
  • 40 A rated current for appropriately designed distribution and control applications.
  • UC-Z / Type Z tripping characteristic for sensitive overcurrent protection.
  • 10 kA rated short-circuit capacity.
  • Single-pole DC configuration supports applications up to 220 V DC.
  • 440 V rated insulation voltage and 4 kV impulse withstand voltage.
  • Compact 18 mm, one-module construction conserves distribution-board space.
  • Plug-in design developed specifically for the ABB SMISSLINE TP system.

Key Features

  • ABB SMISSLINE TP S400 M-UC series.
  • 40 A rated current.
  • UC-Z / Type Z tripping characteristic.
  • 1 pole / 1 protected pole.
  • AC/DC voltage type.
  • Single-pole DC application up to 220 V DC.
  • 10 kA rated short-circuit capacity.
  • IP20 degree of protection.
  • Flexible conductor capacity up to 25 mm².
  • Rigid conductor capacity up to 35 mm².
  • 10,000-cycle electrical and mechanical endurance.
  • Compact 18 mm modular width.

Reliable Type Z Protection for AC/DC and DC Circuits

The ABB S401M-UCZ40 protects conductors and connected equipment by automatically disconnecting the circuit when damaging overcurrent conditions occur. Thermal protection responds to sustained overloads, while its Type Z electromagnetic characteristic provides sensitive and rapid response to short-circuit fault currents.

The S400 M-UC design provides flexible AC/DC application capability, while the single-pole S401M-UCZ40 supports DC applications up to 220 V DC when installed in the specified configuration. Combined with its 10 kA short-circuit capacity and SMISSLINE TP plug-in architecture, it provides a compact protection solution for industrial control, automation and DC distribution circuits.

Typical Applications

  • ABB SMISSLINE TP distribution assemblies.
  • Industrial DC distribution circuits.
  • Automation and control equipment.
  • DC auxiliary power systems.
  • Electronic equipment and instrumentation circuits.
  • Machinery and industrial systems requiring sensitive Type Z overcurrent protection.

Technical Specifications

Series SMISSLINE TP S400 M-UC
ABB order code 2CCS571001R1408
Product group SMISSLINE Plug-in System
Product type Miniature circuit breaker (MCB)
Rated current 40 A
Tripping characteristic UC-Z / Type Z
Number of poles 1
Number of protected poles 1
Voltage type AC/DC
Rated operational voltage 230 V AC
Maximum DC voltage, single-pole configuration 220 V DC
Rated short-circuit capacity 10 kA
Frequency 50–60 Hz
Rated insulation voltage (Ui) 440 V
Rated impulse withstand voltage (Uimp) 4 kV
Energy limiting class 3
Overvoltage category III
Pollution degree 2
Protection rating IP20
Operating temperature -25 to +60 °C
Flexible conductor capacity 0.75–25 mm²
Rigid conductor capacity 0.75–35 mm²
Tightening torque 2.8 N·m
Power loss 4.2 W
Electrical endurance 10,000 cycles
Mechanical endurance 10,000 cycles
Width 18 mm
Height 91 mm
Depth 75 mm
Built-in depth 75 mm
Modular width 1 module
Weight 110 g
Packaging unit 10 pieces
EAN 7612270110223
Standard IEC/EN 60947-2
Mounting system SMISSLINE TP plug-in system

Frequently Asked Questions

What is the ABB S401M-UCZ40 used for?

The ABB S401M-UCZ40 provides overload and short-circuit protection for AC/DC and DC circuits within compatible ABB SMISSLINE TP distribution systems.

What is the rated current of the S401M-UCZ40?

The S401M-UCZ40 has a rated current of 40 A.

What tripping characteristic does the S401M-UCZ40 use?

The S401M-UCZ40 uses a UC-Z / Type Z tripping characteristic, providing sensitive overcurrent protection for appropriately engineered circuits.

What DC voltage can the single-pole S401M-UCZ40 be used with?

The single-pole S401M-UCZ40 can be used for DC applications up to 220 V DC. The specified connection arrangement and polarity requirements for DC operation must be observed.

What is the short-circuit capacity of the ABB S401M-UCZ40?

The S401M-UCZ40 has a rated short-circuit capacity of 10 kA, providing robust fault protection for appropriately engineered SMISSLINE TP circuits.

Trusted ABB AC/DC Circuit Protection

ABB SMISSLINE TP S400 M-UC miniature circuit breakers combine flexible AC/DC capability, sensitive Type Z overcurrent protection and compact plug-in construction for dependable industrial control and distribution applications.