2CCS571001R1258 ABB S401M-UCZ25 AC/DC Miniature Circuit Breaker 25 A Type Z 1P

2CCS571001R1258 ABB S401M-UCZ25 AC/DC Miniature Circuit Breaker 25 A Type Z 1P

ABB S401M-UCZ25 is a 25 A single-pole Type Z AC/DC miniature circuit breaker for the SMISSLINE TP plug-in system, providing sensitive overload and short-circuit protection for commercial and industrial circuits.

SKU: 2CCS571001R1258Alt SKU: S401MUCZ25MPN: 2CCS571001R1258
Price
List Price £79.88 ex VAT
Your Price (ex VAT) Save 35%
£51.92 35% OFF
You save £27.96 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £51.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£51.92

Why Choose the ABB S401M-UCZ25 Miniature Circuit Breaker?

The ABB S401M-UCZ25 is a high-performance single-pole miniature circuit breaker (MCB) designed for overload and short-circuit protection in AC and DC electrical circuits. Part of the ABB S400M UC range for the SMISSLINE TP plug-in system, it combines flexible AC/DC circuit protection with a pluggable format for commercial, industrial and critical-power installations.

Featuring a 25 A rated current and UC-Z / Type Z tripping characteristic, the S401M-UCZ25 provides sensitive overcurrent protection for electronic equipment, control systems and other circuits requiring a comparatively low magnetic trip threshold. Its thermal-magnetic operating principle protects conductors and connected equipment against both sustained overloads and short circuits.

The S401M-UCZ25 supports single-pole operation up to 220 V DC and provides a 10 kA rated service short-circuit breaking capacity at 220 V DC. Its compact 18 mm-wide construction and SMISSLINE TP plug-in architecture enable efficient installation, replacement and system expansion.

Key Advantages

  • Compact AC/DC miniature circuit breaker for overload and short-circuit protection.
  • 25 A rated current for a wide range of control and distribution circuits.
  • UC-Z / Type Z tripping characteristic for sensitive overcurrent protection.
  • Suitable for single-pole DC applications up to 220 V DC.
  • 10 kA service short-circuit breaking capacity at 220 V DC.
  • Plug-in construction for direct integration with the ABB SMISSLINE TP system.

Key Features

  • ABB S400M UC / SMISSLINE TP series.
  • 25 A rated current.
  • UC-Z / Type Z tripping characteristic.
  • 1-pole protected configuration.
  • Suitable for AC and DC applications.
  • 10 kA rated short-circuit capacity at 230 V AC.
  • 15 kA ultimate short-circuit breaking capacity at 230 V AC.
  • 440 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • Compliant with IEC/EN 60947-2.

Sensitive AC/DC Circuit Protection for SMISSLINE TP Systems

Miniature circuit breakers such as the ABB S401M-UCZ25 automatically interrupt the electrical supply when excessive current results from an overload or short circuit. This helps protect conductors, electronic equipment and connected devices against potentially damaging electrical fault conditions.

The ABB S400M UC range extends the SMISSLINE TP platform with miniature circuit breakers suitable for both AC and DC applications. Combined with its Type Z characteristic, the S401M-UCZ25 is particularly suitable for applications where sensitive magnetic overcurrent protection, high short-circuit performance and efficient plug-in installation are required.

Typical Applications

  • DC control and auxiliary circuits.
  • Industrial automation and machine control systems.
  • Electronic equipment protection.
  • Instrumentation and measurement circuits.
  • SMISSLINE TP distribution systems.
  • Commercial, industrial and critical-power installations.

Technical Specifications

Series S400M UC / SMISSLINE TP
ABB order code 2CCS571001R1258
EAN 7612270110209
Product type AC/DC miniature circuit breaker (MCB)
Number of poles 1
Number of protected poles 1
Rated current 25 A
Tripping characteristic UC-Z / Type Z
Rated operational voltage 230 V AC
Maximum single-pole DC application voltage 220 V DC
Rated short-circuit capacity 10 kA at 230 V AC
Ultimate short-circuit breaking capacity (Icu) 15 kA at 230 V AC
Service short-circuit breaking capacity (Ics) 10 kA at 220 V DC
Rated insulation voltage (Ui) 440 V
Rated impulse withstand voltage (Uimp) 4 kV
Frequency 50–60 Hz
Mounting system SMISSLINE TP plug-in system
Width 18 mm / 1 module
Dimensions (H × W × D) approx. 91 × 18 × 75 mm
Weight approx. 145 g
Standard IEC/EN 60947-2

Frequently Asked Questions

What is the ABB S401M-UCZ25 used for?

The S401M-UCZ25 is a single-pole AC/DC miniature circuit breaker designed to protect electrical circuits against overload and short-circuit conditions within ABB SMISSLINE TP systems.

What is the current rating of the S401M-UCZ25?

The ABB S401M-UCZ25 has a rated current of 25 A.

What tripping characteristic does the S401M-UCZ25 use?

The S401M-UCZ25 uses a UC-Z / Type Z tripping characteristic, providing sensitive magnetic overcurrent protection for electronic, control and similar circuits.

Can the ABB S401M-UCZ25 be used on DC circuits?

Yes. The S401M-UCZ25 is suitable for AC and DC applications, including single-pole operation up to 220 V DC.

What is the breaking capacity of the ABB S401M-UCZ25?

The S401M-UCZ25 has a 10 kA rated short-circuit capacity at 230 V AC, an ultimate short-circuit breaking capacity of 15 kA at 230 V AC, and a service short-circuit breaking capacity of 10 kA at 220 V DC.

Trusted ABB AC/DC Circuit Protection

ABB S400M UC miniature circuit breakers extend the SMISSLINE TP platform with flexible AC and DC circuit protection, combining sensitive tripping characteristics, high short-circuit performance and a modular plug-in architecture for professional electrical distribution systems.