2CCS571001R0557 ABB S401M-K40 Miniature Circuit Breaker 1P Type K 40A 10kA

2CCS571001R0557 ABB S401M-K40 Miniature Circuit Breaker 1P Type K 40A 10kA

ABB S401M-K40 is a 40 A single-pole Type K current-limiting miniature circuit breaker with 10 kA rated short-circuit capacity and 15 kA ultimate short-circuit breaking capacity at 230 V AC, designed for overload and short-circuit protection in SMISSLINE TP plug-in distribution systems.

SKU: 2CCS571001R0557Alt SKU: S401MK40MPN: 2CCS571001R0557
Price
List Price £53.41 ex VAT
Your Price (ex VAT) Save 35%
£34.72 35% OFF
You save £18.69 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £34.72
Trade pricing is personalised to your account

Manufacturer Lead Time

£34.72

Why Choose the ABB S401M-K40 Miniature Circuit Breaker?

The ABB S401M-K40 is a high-performance single-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection within ABB SMISSLINE TP electrical distribution systems. As part of the ABB S400 M-K series, it combines current-limiting circuit protection with the practical plug-in architecture of the SMISSLINE TP system.

The S401M-K40 uses delayed thermal protection for sustained overload conditions together with electromagnetic operation for short-circuit faults. Its Type K tripping characteristic makes it particularly suitable for appropriately engineered circuits supplying inductive equipment and loads that can produce elevated starting currents.

With a rated current of 40 A, a rated operational voltage of 240 V AC and an ultimate short-circuit breaking capacity of 15 kA at 230 V AC according to IEC/EN 60947-2, the S401M-K40 provides robust protection in a compact one-module format. Its SMISSLINE TP plug-in construction supports efficient installation and straightforward integration into compatible ABB distribution assemblies.

Key Advantages

  • Reliable overload and short-circuit protection for electrical circuits.
  • 40 A rated current for demanding commercial and industrial applications.
  • Type K tripping characteristic suited to appropriately designed loads with elevated starting currents.
  • 10 kA rated short-circuit capacity.
  • 15 kA ultimate short-circuit breaking capacity at 230 V AC according to IEC/EN 60947-2.
  • Current-limiting class 3 performance helps reduce fault energy during short circuits.
  • Compact single-pole, one-module construction conserves distribution-board space.
  • Plug-in design developed specifically for the ABB SMISSLINE TP system.

Key Features

  • ABB SMISSLINE TP S400 M-K series.
  • 40 A rated current.
  • Type K tripping characteristic.
  • 1 protected pole.
  • 240 V AC rated operational voltage.
  • 50–60 Hz rated frequency.
  • 10 kA rated short-circuit capacity.
  • 15 kA ultimate short-circuit breaking capacity at 230 V AC.
  • 440 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • IP20 degree of protection.
  • Compact 18 mm modular width.

Reliable Type K Protection for Industrial Circuits

Miniature circuit breakers such as the ABB S401M-K40 protect electrical installations by automatically disconnecting circuits when damaging overcurrent conditions occur. The delayed thermal mechanism responds to sustained overloads, while the electromagnetic mechanism provides rapid interruption during short-circuit faults.

The Type K characteristic is particularly useful for appropriately engineered circuits where connected equipment can produce elevated starting currents during normal operation. Combined with its current-limiting performance and SMISSLINE TP plug-in architecture, the S401M-K40 provides a compact protection solution for industrial controls, machinery, motors and other inductive electrical loads.

Typical Applications

  • ABB SMISSLINE TP plug-in distribution boards.
  • Industrial control and automation systems.
  • Motor and inductive-load circuits.
  • Transformer circuits.
  • Machinery and production equipment.
  • Commercial and industrial electrical distribution systems.

Technical Specifications

Series SMISSLINE TP S400 M-K
ABB order code 2CCS571001R0557
Product group SMISSLINE Plug-in System
Product type Miniature circuit breaker (MCB)
Rated current 40 A
Tripping characteristic Type K
Number of poles 1
Number of protected poles 1
Rated operational voltage 240 V AC
Frequency 50–60 Hz
Rated short-circuit capacity 10 kA
Ultimate short-circuit breaking capacity (Icu) at 230 V AC 15 kA
Ultimate short-circuit breaking capacity (Icu) at 400 V 10 kA
Rated service short-circuit breaking capacity (Ics) at 240 V AC 7.5 kA
Rated insulation voltage (Ui) 440 V
Rated impulse withstand voltage (Uimp) 4 kV
Current limiting class 3
Pollution degree 3
Overvoltage category III
Protection rating IP20
Operating temperature -25 to +60 °C
Multi-wired conductor capacity 0.75–25 mm²
Solid conductor capacity 0.75–35 mm²
Electrical endurance 10,000 cycles
Width 18 mm
Height 91 mm
Built-in depth 75 mm
Modular width 1 module
Weight 110 g
Packaging unit 10 pieces
EAN 7612270101740
Standard IEC/EN 60947-2
Mounting system SMISSLINE TP plug-in system

Frequently Asked Questions

What is the ABB S401M-K40 used for?

The ABB S401M-K40 provides overload and short-circuit protection for electrical circuits within compatible ABB SMISSLINE TP systems, including appropriately designed circuits supplying inductive equipment and loads with elevated starting currents.

What is the rated current of the S401M-K40?

The S401M-K40 has a rated current of 40 A.

What does the Type K tripping characteristic mean?

The Type K characteristic is suitable for appropriately engineered circuits supplying equipment that can produce elevated starting currents, including certain motor, transformer and other inductive-load applications.

What is the short-circuit breaking capacity of the ABB S401M-K40?

The S401M-K40 has a rated short-circuit capacity of 10 kA and an ultimate short-circuit breaking capacity (Icu) of 15 kA at 230 V AC according to IEC/EN 60947-2.

Which distribution system is the S401M-K40 designed for?

The S401M-K40 is a plug-in miniature circuit breaker designed specifically for the ABB SMISSLINE TP system.

Trusted ABB Circuit Protection

ABB SMISSLINE TP S400 M-K miniature circuit breakers combine high-performance current-limiting protection with a compact plug-in architecture for dependable commercial and industrial electrical distribution.